Logic Output Optoisolators

Results: 2
Manufacturer
TT Electronics/Optek TechnologyVishay Semiconductor Opto Division
Voltage - Isolation
5000Vrms16000VDC
Common Mode Transient Immunity (Min)
10kV/µs-
Current - Output / Channel
25 mA50 mA
Data Rate
2Mbps2MHz
Propagation Delay tpLH / tpHL (Max)
200ns, 100ns2µs, 1.2µs
Rise / Fall Time (Typ)
50ns, 40ns-
Voltage - Forward (Vf) (Typ)
1.1V1.3V
Current - DC Forward (If) (Max)
30mA50mA
Voltage - Supply
7V16V
Package / Case
6-DIP (0.400", 10.16mm)6-DIP (1.100", 27.94mm), 5 Leads
Supplier Device Package
6-DIP-
Stocking Options
Environmental Options
Media
Marketplace Product
2Results

Showing
of 2
Compare
Mfr Part #
Quantity Available
Price
Series
Package
Product Status
Number of Channels
Inputs - Side 1/Side 2
Voltage - Isolation
Common Mode Transient Immunity (Min)
Input Type
Output Type
Current - Output / Channel
Data Rate
Propagation Delay tpLH / tpHL (Max)
Rise / Fall Time (Typ)
Voltage - Forward (Vf) (Typ)
Current - DC Forward (If) (Max)
Voltage - Supply
Operating Temperature
Mounting Type
Package / Case
Supplier Device Package
OPI1268, OPI1268S
OPI1268
OPTOISO 16KV OPEN COLLECTOR
TT Electronics/Optek Technology
8,265
In Stock
1 : ¥74.89000
Tube
-
Tube
Active
1
1/0
16000VDC
-
DC
Open Collector
25 mA
2Mbps
200ns, 100ns
-
1.3V
30mA
7V
-40°C ~ 100°C
Through Hole
6-DIP (1.100", 27.94mm), 5 Leads
-
VOH1016AG-V
VOH1016AG-V
OPTOISO 5KV OPEN COLLECTOR 6-DIP
Vishay Semiconductor Opto Division
1,004
In Stock
1 : ¥9.52000
Tube
-
Tube
Active
1
1/0
5000Vrms
10kV/µs
DC
Open Collector
50 mA
2MHz
2µs, 1.2µs
50ns, 40ns
1.1V
50mA
16V
-40°C ~ 100°C
Through Hole
6-DIP (0.400", 10.16mm)
6-DIP
Showing
of 2

Logic Output Optoisolators


Logic output optoisolators use light to transmit information across an electrical insulation barrier, usually for safety or functional reasons. They are distinguished from other styles of optoisolator products by the incorporation of additional output stage circuitry for amplification and threshold detection, providing output signals that are compatible with common logic signal levels. These additional circuits require provision of an external power source for proper operation.