HF3 Relay Datasheet by TE Connectivity Potter & Brumfield Relays

- - TE RELAY — PRouucrs mnnerllvlly
06-2015, Rev. 0615
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
1
AXICOM
RF Signal Relays
n Y-Design
n Frequency range DC to 3GHz
n Impedance 50Ω or 75Ω
n Small dimensions (14.6x7.2x10mm)
n 1 form C contact (1 changeover contact)
n Immersion cleanable
n Low power consumption (≤140mW)
Typical applications
Cable modems and linecards/ CATV, Tabs, measurement and test
equipment ATE, satellite / audio / video tuners, wireless base stations and
antennas, switching boards
Contact Data
Contact arrangement 1 form C, 1 CO
Max. switching voltage 220VDC, 250VAC
Rated current 2A
Limiting continuous current, 23°C 2A
Switching power 60W, 62.5VA,
50W (2.5GHz)
Max. continuos RF-power, 23°C 50W (2.5GHz)
Contact material Ag, Au covered
Minimum switching voltage 100µV
Initial contact resistance <100mΩ at 10mA, 30mV
Operate time typ. 3ms, max. 5ms
Release time
without diode in parallel typ. 2ms, max. 5ms
with diode in parallel typ. 4ms, max. 6ms
Bounce time typ. 1ms, max. 3ms
Duration of set/reset pulse min. 20ms
Mechanical endurance 107 operations
Coil Data
Coil voltage range 3 to 24VDC
Coil versions, monostable
Coil Rated Operate Limiting Release Coil Rated coil
code voltage voltage voltage voltage resistance power
VDC VDC VDC VDC Ω±10% mW
50Ω version, monostable, 1 coil
51 3 2.25 6.50 0.30 64 140
52 4.5 3.38 9.80 0.45 145 140
53 5 3.75 10.90 0.50 178 140
54 6 4.50 13.00 0.60 257 140
55 9 6.75 19.60 0.90 574 140
56 12 9.00 26.10 1.20 1028 140
57 24 18.00 52.30 2.40 4114 140
75Ω version, monostable, 1 coil
01 3 2.25 6.50 0.30 64 140
02 4.5 3.38 9.80 0.45 145 140
03 5 3.75 10.90 0.50 178 140
04 6 4.50 13.00 0.60 257 140
05 9 6.75 19.60 0.90 574 140
06 12 9.00 26.10 1.20 1028 140
07 24 18.00 52.30 2.40 4114 140
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coil Data (continued)
Coil versions, bistable
Coil Rated Set Limiting Reset Coil Rated coil
code voltage voltage voltage voltage resistance power
VDC VDC VDC VDC Ω±10% mW
50Ω version, bistable, 1 coil
71 3 2.25 9.20 -2.25 128 70
72 4.5 3.38 13.85 -3.38 289 70
73 5 3.75 15.30 -3.75 357 70
74 6 4.50 18.50 -4.50 514 70
75 9 6.75 27.70 -6.75 1157 70
76 12 9.00 37.00 -9.00 2057 70
77 24 18.00 74.00 -18.00 8228 70
50Ω version, bistable, 2 coils
91 3 2.25 6.50 2.25 64 140
92 4.5 3.38 9.80 3.38 145 140
93 5 3.75 10.90 3.75 178 140
94 6 4.50 13.00 4.50 257 140
95 9 6.75 19.60 6.75 574 140
96 12 9.00 26.10 9.00 1028 140
97 24 18.00 52.30 18.00 4114 140
All figures are given for coil without pre-energization, at ambient temperature +23°C.
Coil Data (continued)
Coil versions, bistable
Coil Rated Set Limiting Reset Coil Rated coil
code voltage voltage voltage voltage resistance power
VDC VDC VDC VDC Ω±10% mW
75Ω version, bistable, 1 coil
21 3 2.25 9.20 -2.25 128 70
22 4.5 3.38 13.85 -3.38 289 70
23 5 3.75 15.30 -3.75 357 70
24 6 4.50 18.50 -4.50 514 70
25 9 6.75 27.70 -6.75 1157 70
26 12 9.00 37.00 -9.00 2057 70
27 24 18.00 74.00 -18.00 8228 70
75Ω version, bistable, 2 coils
41 3 2.25 6.50 2.25 64 140
42 4.5 3.38 9.80 3.38 145 140
43 5 3.75 10.90 3.75 178 140
44 6 4.50 13.00 4.50 257 140
45 9 6.75 19.60 6.75 574 140
46 12 9.00 26.10 9.00 1028 140
47 24 18.00 52.30 18.00 4114 140
All figures are given for coil without pre-energization, at ambient temperature +23°C.
HF3 Relay
- - TE RELAY — PRouucrs mnnerllvlly
06-2015, Rev. 0615
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
2
AXICOM
RF Signal Relays
HF3 Relay (Continued)
RF Data
Isolation
at 100MHz/900MHz 80dB/72dB 80dB/72dB
at 3GHz 45dB 40dB
Insertion loss
at 100MHz/900MHz 0.03dB/0.12dB 0.03dB/0.12dB
at 3GHz 0.35dB 0.40dB
Voltage standing wave ratio (VSWR)
at 100MHz/900MHz/3GHz 1.05/1.20/1.20 1.05/1.20/1.40
Other Data
Material compliance: EU RoHS/ELV, China RoHS, REACH, Halogen content
refer to the Product Compliance Support Center at
www.te.com/customersupport/rohssupportcenter
Ambient temperature -55°C to +85°C
Thermal resistance <165K/W
Category of environmental protection
IEC 61810 RT III - wash tight
Degree of protection, IEC 60529 IP 67, immersion cleanable
Vibration resistance (functional) 35g, 10 to 1000Hz
Shock resistance (functional), half sinus 11ms 50g
Shock resistance (destructive), half sinus 0.5ms 150g
Terminal type SMT
Weight max. 2.5g
Resistance to soldering heat SMT Peak Value
IEC 60068-2-58 265°C
Moisture sensitive level, JEDEC J-Std-020D MSL3
Ultrasonic cleaning not recommended
Packaging/unit reel/400 pcs., box/400 or 2000 pcs.
Insulation Data 50Ω version 75Ω version
Initial dielectric strength
between open contacts 600Vrms
between contact and coil 1000Vrms
Initial surge withstand voltage
between open contacts 1000V
between contact and coil 1500V
108-98000 Rev. F
All specifications subject to change. Consult Tyco Electronics for latest specifications. 5 of 12
Telecom-, Signal and RF Relays
HF3 Relay
AXICOM
Umax. at 0 A
Uop. min.
Urel. min.
140 mW
Coil Voltage [U/Unom]
Ambient Temperature [°C]
Terminal assignment
Relay top view
Non-latching type,
not energized condition
Latching type, 2 coils
reset condition
Latching type, 1 coil
rest condition
Coil Operating Range
0
0.5
1
1.5
2
2.5
3
3.5
-55-45 -35-25 -15-5515 25 35 45 55 65 75 85 95 105115 125135
Unom. nominal coil voltage
Umax. at 0 A
Uop. min.
70 mW
Coil Voltage [U/Unom]
Ambient Temperature [°C]
Unom. nominal coil voltage
Unom = Nominal coil voltage
Umax. = Upper limit of the operative range of
the coil voltage (limiting voltage)
Uop. min. = Lower limit of the operative range of
the coil voltage (reliable operate voltage)
For latching relays Uset min. resp. Ureset min.
Urel. min. = Lower limit of the operative range of
the coil voltage (reliable release voltage)
140 mW 70 mW
Contacts in reset position. Contact po-
sition might change during transporta-
tion and must be reset before use.
108-98000 Rev. F
All specifications subject to change. Consult Tyco Electronics for latest specifications. 5 of 12
Telecom-, Signal and RF Relays
HF3 Relay
AXICOM
Umax. at 0 A
Uop. min.
Urel. min.
140 mW
Coil Voltage [U/U
nom
]
Ambient Temperature [°C]
Terminal assignment
Relay top view
Non-latching type,
not energized condition
Latching type, 2 coils
reset condition
Latching type, 1 coil
rest condition
Coil Operating Range
0
0.5
1
1.5
2
2.5
3
3.5
-55-45 -35-25 -15-5515 25 35 45 55 65 75 85 95 105115 125135
Unom. nominal coil voltage
Umax. at 0 A
Uop. min.
70 mW
Coil Voltage [U/Unom]
Ambient Temperature [°C]
Unom. nominal coil voltage
Unom = Nominal coil voltage
Umax. = Upper limit of the operative range of
the coil voltage (limiting voltage)
Uop. min. = Lower limit of the operative range of
the coil voltage (reliable operate voltage)
For latching relays Uset min. resp. Ureset min.
Urel. min. = Lower limit of the operative range of
the coil voltage (reliable release voltage)
140 mW 70 mW
Contacts in reset position. Contact po-
sition might change during transporta-
tion and must be reset before use.
Coil operating Range
- - TE RELAY — PRouucrs mnnerllvlly 01 ~~~~~~~~ ‘ -\.‘ \ZS-Z’r \ F1 ‘25 ‘ I l ””71 V. ‘4 r z“ / 1» w [ % + j? 4 L49 P w % +
06-2015, Rev. 0615
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
3
AXICOM
RF Signal Relays
HF3 Relay (Continued)
NO
NC
-0.4
-0.3
-0.2
-0.1
0.0
0.1
0 500 1000 1500 2000 2500 3000
Frequency [Mhz]
Insertion-loss [dB]
Typical RF performance, 50Ω version (continued) Typical RF performance, 75Ω version (continued)
NO
NC
-0.4
-0.3
-0.2
-0.1
0.0
0.1
0 500 1000 1500 2000 2500
Frequency [Mhz]
Insertion-loss [dB]
NO
NC
1.00
1.05
1.10
1.15
1.20
1.25
0 500 1000 1500 2000 2500 3000
VSWR
NO
NC
1.00
1.05
1.10
1.15
1.20
1.25
0 500 1000 1500 2000 2500
Frequency[Mhz]
VSWR
Terminal assignment
TOP view on component side of PCB
Monostable Bistable, 1 coil
Contacts are shown in reset condition.
Contact position might change during
transportation and must be reset before
use.
Bistable, 2 coils
1
12
2 3 4 5 6 7 8 9 10 11
13141516171819202122
HF3-PIN-2SPULEN
+ -
+
-
reset
set
+
-
+-
reset
set
NO
NC
-120
-100
-80
-60
-40
-20
0
0 500 1000 1500 2000 2500 3000
Frequency [Mhz]
Isolation [dB]
Typical RF performance, 50Ω version Typical RF performance, 75Ω version
NC
NO
-120
-100
-80
-60
-40
-20
0
0 500 1000 1500 2000 2500
Frequency [Mhz]
Isolation [dB]
- - TE RELAY — PRouucrs mnnerllvlly mm mm; W ”MW ‘ "‘ c? 32 \I ‘4 »—+D r—b—D 1 1 x i A; i J i '3 ‘ , ‘ , ‘ Y ‘ v 7 ‘ l 4‘ \ 4‘5 2: 57 m ECU 3 447+ 2 ”H 03‘ m as 05‘ m H Y AWAW H H H IJWA H gmAilcm PT EVEA ICOM PT HFifl 7 Hg“ , 22V IDC} w 22V DC} Wm H1 W H' M m M m M g ‘ \l ‘ ‘1 5 5 5 5 D95 H5 5 Has 5 5
06-2015, Rev. 0615
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
4
AXICOM
1 PLC
0 PLC
2 PLC
3 PLC
4 PLC
DIMENSIONS:
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
ANGLES
WEIGHT
APPLICATION SPEC
PRODUCT SPEC
OF
MATERIAL FINISHDWN
CHK
APVD
NAME
SIZE CAGE CODE DRAWING NO
SCALE SHEET REV
LOC DIST
RELEASED FOR PUBLICATION
C
COPYRIGHT ALL RIGHTS RESERVED.
THIS DRAWING IS UNPUBLISHED.
REVISIONS
P LTR DATE DWN APVDDESCRIPTION
1469-35 (3/11)
A4
RESTRICTED TO
THIS DRAWING IS A CONTROLLED DOCUMENT.
TE Connectivity
A
7.2+0.1
-0.1
14.6+0.1
-0.1
0.9+0.1
-0.1
0.40.8
0.8 0.5
0.5
3.81+0.1
-0.1 3.81+0.1
-0.1
0.5
6.35+0.15
-0.15 6.35+0.15
-0.15
9.4+0.2
-0.2
5.08+0.1
-0.1
5.08+0.1
-0.1
4.9
10+0.5
0
2
2.54+0.1
-0.1
2.54+0.1
-0.1
5.08+0.1
-0.1
5.08+0.1
-0.1
1.27+0.1
-0.1
1.27+0.1
-0.1
0.95
6.7
5
6
10
7.2
0.5
0.9
0.5
0.7
0.9
0.6
0.9
0.95
14.6
0.5
1.27
2.54
XX = Relay type
zz = nominal voltage
YYWW = Date code
NNNN = Lot number
0.1 A
1
12
23456 7 89 10 11
13141516
17
18
19
202122
Relay housing
A-A
CPrinting
21JUL2009
UKo HD
DPrinting
09JUL2010
UKo HD
D1 REVISED PER ECO-11-005150
25MAR2011
UKo HMR
D2 REVISED PER ECO-11-017072 (ECR-13-009645)
14JUN2013
UKo AK
HJ -
2005
2005 BY TE Connectivity
16AUG2002
mm UKo 9193 - -
16AUG2002
HD 9121
16AUG2002
DIN 7168-m HD 9121
-
-HF3-Relay 75
--
-Dimensions
-
--
-00779 1462050-2 -
CUSTOMER DRAWING 3:1 1 1 D2
Coplanarity<=0.10mm
RF Signal Relays
HF3 Relay (Continued)
PCB layout
TOP view on component side of PCB
50Ω version 75Ω version
Dimensions
50Ω version 75Ω version
1 PLC
0 PLC
2 PLC
3 PLC
4 PLC
DIMENSIONS:
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
ANGLES
WEIGHT
APPLICATION SPEC
PRODUCT SPEC
OF
MATERIAL FINISHDWN
CHK
APVD
NAME
SIZE CAGE CODE DRAWING NO
SCALE SHEET REV
LOC DIST
RELEASED FOR PUBLICATION
C
COPYRIGHT ALL RIGHTS RESERVED.
THIS DRAWING IS UNPUBLISHED.
REVISIONS
P LTR DATE DWN APVDDESCRIPTION
1469-35 (3/11)
A4
RESTRICTED TO
THIS DRAWING IS A CONTROLLED DOCUMENT.
TE Connectivity
A
7.2+0.1
-0.1
14.6+0.1
-0.1
0.9+0.1
-0.1
0.40.8
0.8 0.8
0.8
3.81+0.1
-0.1 3.81+0.1
-0.1
0.5
6.35+0.15
-0.15 6.35+0.15
-0.15
9.4+0.2
-0.2
5.08+0.1
-0.1
5.08+0.1
-0.1
4.9
10+0.5
0
2
2.54+0.1
-0.1
2.54+0.1
-0.1
5.08+0.1
-0.1
5.08+0.1
-0.1
1.27+0.1
-0.1
1.27+0.1
-0.1
0.95
6.7
5
6
10
7.2
0.9
0.9
0.9
0.7
0.9
0.7
0.9
0.95
14.6
0.9
1.27
2.54
XX = Relay type
zz = nominal voltage
YYWW = Date code
NNNN = Lot number
0.1 A
1
12
23456 7 89 10 11
13141516
17
18
19
202122
Relay housing
A-A
CPrinting
21JUL2009
UKo HD
DPrinting
09JUL2010
UKo HD
D1 REVIESED PER eco-11-005150
09JUL2010
RK HMR
D2 REVISED PER ECO-11-017072 (ECR-13-009645)
14JUN2013
UKo AK
HJ -
2005
2005 BY TE Connectivity
16AUG2002
mm UKo 9193 - -
16AUG2002
HD 9121
16AUG2002
DIN 7168-m HD 9121
-
-HF3-Relay 50
--
-Dimensions
-
1-
-00779 1462051-2 -
CUSTOMER DRAWING 3:1 1 1 D2
Coplanarity<=0.10mm
DRAWING ALIAS: H2000-DOK02
1 PLC
0 PLC
2 PLC
3 PLC
4 PLC
DIMENSIONS:
TOLERANCES UNLESS
OTHERWISE SPECIFIED:
ANGLES
WEIGHT
APPLICATION SPEC
PRODUCT SPEC
OF
MATERIAL FINISHDWN
CHK
APVD
NAME
SIZE CAGE CODE DRAWING NO
SCALE SHEET REV
LOC DIST
RELEASED FOR PUBLICATION
C
COPYRIGHT ALL RIGHTS RESERVED.
THIS DRAWING IS UNPUBLISHED.
REVISIONS
P LTR DATE DWN APVDDESCRIPTION
1469-35 (3/11)
A4
RESTRICTED TO
THIS DRAWING IS A CONTROLLED DOCUMENT.
TE Connectivity
A
7.2+0.1
-0.1
14.6+0.1
-0.1
0.9+0.1
-0.1
0.40.8
0.8 0.5
0.5
3.81+0.1
-0.1 3.81+0.1
-0.1
0.5
6.35+0.15
-0.15 6.35+0.15
-0.15
9.4+0.2
-0.2
5.08+0.1
-0.1
5.08+0.1
-0.1
4.9
10+0.5
0
2
2.54+0.1
-0.1
2.54+0.1
-0.1
5.08+0.1
-0.1
5.08+0.1
-0.1
1.27+0.1
-0.1
1.27+0.1
-0.1
0.95
6.7
5
6
10
7.2
0.5
0.9
0.5
0.7
0.9
0.6
0.9
0.95
14.6
0.5
1.27
2.54
XX = Relay type
zz = nominal voltage
YYWW = Date code
NNNN = Lot number
0.1 A
1
12
23456 7 89 10 11
13141516
17
18
19
202122
Relay housing
A-A
CPrinting
21JUL2009
UKo HD
DPrinting
09JUL2010
UKo HD
D1 REVISED PER ECO-11-005150
25MAR2011
UKo HMR
D2 REVISED PER ECO-11-017072 (ECR-13-009645)
14JUN2013
UKo AK
HJ -
2005
2005 BY TE Connectivity
16AUG2002
mm UKo 9193 - -
16AUG2002
HD 9121
16AUG2002
DIN 7168-m HD 9121
-
-HF3-Relay 75
--
-Dimensions
-
--
-00779 1462050-2 -
CUSTOMER DRAWING 3:1 1 1 D2
Coplanarity<=0.10mm
- - TE RELAY — PRouucrs 26a 22v 165 Temperamre s Q i g 230 245 77c mnnerllvlly Recommended renew soldevlng promo zas'c 23S‘C , , , IEC 51750-1 SnAgCu 150’; ‘ ' / typical max z-c/s' 0 Resistance m soldering heal ‘ max 905 max, 5’ C/s Tune [5] 400 sou ‘205 max 3 °C/s Recommended somenng condmons 500 m 2125c , Dmmavmnmmk \ w o .x‘n n a n . 0“ n . s i \ =12. qumnan \ L
06-2015, Rev. 0615
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
5
AXICOM
RF Signal Relays
HF3 Relay (Continued)
Processing
full line: typical
dotted line: process limits
external preheating
240°C
180°C
130°C
100°C
forced cooling
20 to 40s
Time [s]
Temperature [°C]
Vapour phase soldering
temperature/time profile
(lead and housing peak temp.)
Recommended soldering conditions
Vapour phase soldering
Time [s]
Temperature [°C]
Resistance to soldering heat
Infrared soldering
temperature/time profile
(lead and housing peak temp.)
Packing
Tape and reel for SMT
Reel dimensions
- - TE RELAY - PRODUCTS cannetllvlly
06-2015, Rev. 0615
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
Datasheets and product data is subject to the
terms of the disclaimer and all chapters of
the ‘Definitions’ section, available at
http://relays.te.com/definitions
Datasheets, product data, ‘Definitions’ sec-
tion, application notes and all specifications
are subject to change.
6
AXICOM
RF Signal Relays
HF3 Relay (Continued)
Product code structure Typical product code HF3 53
Type
HF3 Signal Relays HF3 Series
1 form C, 1 CO
Coil
Coil code: please refer to coil versions table
Performance type
5x 50Ω version, monostable 1coil 0x 75Ω version, monostable 1coil
7x 50Ω version, bistable 1coil 2x 75Ω version, bistable 1coil
9x 50Ω version, bistable 2coils 4x 75Ω version, bistable 2coils
Product code Arrangement Version Coil Coil type Part number
HF3 51 1 form C (1 CO) 50ohm 3VDC Monostable 1462051-1
HF3 52 4.5VDC 1-1462051-6
HF3 53 5VDC 1462051-2
HF3 54 6VDC 1-1462051-7
HF3 55 9VDC 1462051-3
HF3 56 12VDC 1462051-4
HF3 57 24VDC 1462051-5
HF3 71 1 form C (1 CO) 50ohm 3VDC Bistable 1 coil 1462051-6
HF3 72 4.5VDC 1-1462051-8
HF3 73 5VDC 1462051-7
HF3 76 12VDC 1462051-9
HF3 91 1 form C (1 CO) 50ohm 3VDC Bistable 2 coils 1-1462051-1
HF3 92 4.5VDC 2-1462051-0
HF3 93 5VDC 1-1462051-2
HF3 95 9VDC 1-1462051-3
HF3 96 12VDC 1-1462051-4
HF3 97 24VDC 1-1462051-5
HF3 01 1 form C (1 CO) 75ohm 3VDC Monostable 1462050-1
HF3 02 4.5VDC 1-1462050-6
HF3 03 5VDC 1462050-2
HF3 06 12VDC 1462050-4
HF3 07 24VDC 1462050-5
HF3 21 1 form C (1 CO) 75ohm 3VDC Bistable 1 coil 1462050-6
HF3 23 5VDC 1462050-7
HF3 26 12VDC 1462050-9
HF3 41 1 form C (1 CO) 75ohm 3VDC Bistable 2 coils 1-1462050-1
HF3 43 5VDC 1-1462050-2
HF3 46 12VDC 1-1462050-4
HF3 47 24VDC 1-1462050-5
This list represents the most common types and does not show all variants covered by this data sheet.
Other types on request