Gen7 Vero® 18 Array Series Datasheet by Bridgelux

1
Bridgelux® Gen 7 Vero® 18 Array
Product Data Sheet DS92
@cwus@:,/MC€
Introduction
Vero® Series is a revolutionary advancement in chip on board (COB) light source technology and innovation. Vero LED light
sources simplify luminaire design and manufacturing processes Vero Chip on Board (COB) LED arrays are available in four
LES configurations, engineered to enable new degrees of flexibility and reliability over a broad range of electrical currents.
Vero arrays deliver increased lumen density to enable improved beam control and precision lighting with 2 and 3 SDCM color
control standard for clean and consistent uniform lighting.
Vero products include an onboard connector port that enables a solder-free electrical interconnect, and simple mounting
features for plug-and-play installation.
Bridgelux Décor Series™ is our state-of-the-art color line designed specifically for premium applications, producing unmatched
LED light quality with brilliant color-rendering options and pleasing lighting palettes. Bridgelux Décor Series color points are
available on Vero® SE Series, Vero® Series, V Series™ and V Series™ HD.
Décor SeriesClass A is based on human response testing, providing color points with a combined GAI and CRI metric.
Décor Series™ Ultra products provide a high CRI of 97 and typical R9 value of 98, which emphasizes the reds and color tones
to which the human eye is most receptive - perfect for the most luxurious retail shops and world renowned museums. Décor
Series Ultra is designed as a replacement for halogen lamps.
Décor Series™ Food products offer color points developed to address the unique requirements of the food, grocery, and
restaurant industries. Highlighting the distinctive colors and nuanced patterns found in meats and breads, the Décor Series
Food products are a must have for any butcher counter or bakery.
Décor Series ™ Entertainment products provide color points developed specifically for the healthcare and entertainment
industries. The 5600K cool white color point combined with a CRI of 90 or 97 provides the bright white required by these
industries.
Décor Series™ Street and Landmark is designed to be a direct replacement for high pressure sodium lamps.
Décor Series™ Showcase is the optimal solution for replacing ceramic metal halide lamps, incorporating the same pure white
light with enhanced spectrum coverage and higher efficacy.
Vero® Series
Features
Efficacy of 160 lm/W typical for 3000K 80 CRI
Lumen output performance ranges from 1,455 to
13,600 lumens
Broad range of CCT options from 1750K to 6500K
CRI options include minimum 65, 70, 80, 90, 95 and
Class A
Reliable operation at up to 2X nominal drive current
Radial die pattern and improved lumen density
Thermally isolated solder pads
Onboard connector port
Top side part number markings
• Vf bin code backside marking
Benefits
Broad application coverage for interior and exterior
lighting
Flexibility for application driven lighting design
requirements
High quality true color reproduction
Uniform consistent white light
Flexibility in design optimization
Enhanced ease of use and assembly
Solderless connectivity enables plug & play
installation and field upgradability
Improved inventory management and quality control
1
Contents
Product Feature Map 2
Product Nomenclature 2
Product Selection Guide 3
Performance at Commonly Used Drive Currents 10
Electrical Characteristics 20
Eye Safety 21
Absolute Maximum Ratings 22
Performance Curves 23
Typical Radiation Pattern 27
Typical Color Spectrum 28
Mechanical Dimensions 29
Color Binning Information 30
Packaging and Labeling 31
Design Resources 33
Precautions 33
Disclaimers 33
About Bridgelux 34
#mijm BLE—
2
Product Feature Map
Vero 18 is the second largest form factor in the Vero
family of next generation solid state light sources. In
addition to delivering the performance and light quality
required for many lighting applications, Vero incorporates
Product Nomenclature
The part number designation for Bridgelux Vero LED arrays is explained as follows:
several features to simplify the design integration and
manufacturing process, accelerate time to market and
reduce system costs. Please visit www.bridgelux.com for
more information on the Vero Series family of products.
1 2 3 4 5 6 7 8 9 10 11 – 12 – 13 14
Product Family CCT Bin Options
2 = 2 SDCM
3 = 3 SDCM
4 = 4 SDCM
CRI
B = 65 CRI min.
C = 70 CRI min.
E = 80 CRI min.
G = 90 CRI min.
H = 97 CRI typ.
A = Class A
Array Configuration
17 = 1,750K
20 = 2,000K
25 = 2,500K
27 = 2,700K
30 = 3,000K
35 = 3,500K
40 = 4,000K
50 = 5,000K
56 = 5,600K
57 = 5,700K
65 = 6,500K
BXRC 30 E 400 0 C 7 3
2D Bar code provides full manufacturing traceability
Polarity indication marks simplify
manufacturing operator instructions
Optics location/mounting features
Mounting holes
Zhaga Book 3 compatible
mounting locations
Solderless connector port enables simplified
manufacturing processes, reduced inventory
carrying costs and can enable field upgradability
Thermally isolated solder pads reduce
manufacturing cycle time and complexity
Tc Measurement point
Radial die configuration improves lumen
density and beam control
Optional Molex Pico-EZmate connector harness
(sold separately)
Top side part number marking improves
inventory management and outgoing
quality control
Color Targeting Designator
0 = Cold Targeted
1 = Hot Targeted
C = Decor Series Showcase Target
Gen. 7
Nominal CCT
Flux Indicator
400x = 4000 lm
3
Product Selection Guide
The following product configurations are available:
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-17E4000-B-74 1750 80 900 2774 2497 34.8 31.3 89
BXRC-17E4000-C-74 1750 80 1170 3624 3261 34.8 40.7 89
BXRC-17E4000-D-74 1750 80 1050 2710 2439 29.0 30.5 89
BXRC-20B4001-C-73 2000 65 1170 6081 5473 34.8 40.7 149
BXRC-20B4001-D-73 2000 65 1050 4548 4093 29.0 30.5 149
BXRC-25E4000-B-74 2500 80 900 4484 4036 34.8 31.3 143
BXRC-25E4000-C-74 2500 80 1170 5829 5246 34.8 40.7 143
BXRC-25E4000-D-74 2500 80 1050 4360 3924 29.0 30.5 143
BXRC-27E4000-B-7x 2700 80 900 4807 4326 34.8 31.3 153
BXRC-27E4000-C-7x 2700 80 1170 6249 5624 34.8 40.7 153
BXRC-27E4000-D-7x 2700 80 1050 4673 4206 29.0 30.5 153
BXRC-27G40H0-B-7x 2700 90 900 4166 3749 34.8 31.3 133
BXRC-27G40H0-C-7x 2700 90 1170 5415 4874 34.8 40.7 133
BXRC-27G40H0-D-7x 2700 90 1050 4050 3645 29.0 30.5 133
BXRC-27G4000-B-7x 2700 90 900 4000 3600 34.8 31.3 128
BXRC-27G4000-C-7x 2700 90 1170 5200 4680 34.8 40.7 128
BXRC-27G4000-D-7x 2700 90 1050 3889 3500 29.0 30.5 128
BXRC-27H4000-B-7x 2700 97 900 3484 3136 34.8 31.3 111
BXRC-27H4000-C-7x 2700 97 1170 4529 4076 34.8 40.7 111
BXRC-27H4000-D-7x 2700 97 1050 3387 3049 29.0 30.5 111
BXRC-30C4001-B-74 3000 70 900 5512 4961 34.8 31.3 176
BXRC-30C4001-C-74 3000 70 1170 7166 6449 34.8 40.7 176
BXRC-30C4001-D-74 3000 70 1050 5359 4823 29.0 30.5 176
BXRC-30E4000-B-7x 3000 80 900 5000 4500 34.8 31.3 160
BXRC-30E4000-C-7x 3000 80 1170 6500 5850 34.8 40.7 160
BXRC-30E4000-D-7x 3000 80 1050 4861 4375 29.0 30.5 160
BXRC-30G40H0-B-7x 3000 90 900 4353 3918 34.8 31.3 139
BXRC-30G40H0-C-7x 3000 90 1170 5660 5094 34.8 40.7 139
BXRC-30G40H0-D-7x 3000 90 1050 4233 3809 29.0 30.5 139
BXRC-30G4000-B-7x 3000 90 900 4161 3745 34.8 31.3 133
BXRC-30G4000-C-7x 3000 90 1170 5410 4869 34.8 40.7 133
BXRC-30G4000-D-7x 3000 90 1050 4046 3641 29.0 30.5 133
BXRC-30G400C-B-73 3000 90 900 3871 3484 34.8 31.3 124
BXRC-30G400C-D-73 3000 90 1050 3764 3387 29.0 30.5 124
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all other
products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products is 93. Brid-
gelux maintains a ± 3 tolerance on CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.
4
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-30H4000-B-7x 3000 97 900 3710 3339 34.8 31.3 118
BXRC-30H4000-C-7x 3000 97 1170 4823 4341 34.8 40.7 118
BXRC-30H4000-D-7x 3000 97 1050 3607 3246 29.0 30.5 118
BXRC-30A4001-B-738,9 3000 93 900 3758 3383 34.8 31.3 120
BXRC-30A4001-C-738,9 3000 93 1170 4886 4397 34.8 40.7 120
BXRC-30A4001-D-738,9 3000 93 1050 3654 3289 29.0 30.5 120
BXRC-35E4000-B-7x 3500 80 900 5162 4645 34.8 31.3 165
BXRC-35E4000-C-7x 3500 80 1170 6710 6039 34.8 40.7 165
BXRC-35E4000-D-7x 3500 80 1050 5018 4516 29.0 30.5 165
BXRC-35G4000-B-7x 3500 90 900 4291 3861 34.8 31.3 137
BXRC-35G4000-C-7x 3500 90 1170 5578 5020 34.8 40.7 137
BXRC-35G4000-D-7x 3500 90 1050 4171 3754 29.0 30.5 137
BXRC-35A4001-B-738,9 3500 93 900 4040 3636 34.8 31.3 129
BXRC-35A4001-C-738,9 3500 93 1170 5252 4727 34.8 40.7 129
BXRC-35A4001-D-738,9 3500 93 1050 3928 3535 29.0 30.5 129
BXRC-40C4001-B-74 4000 70 900 5645 5081 34.8 31.3 180
BXRC-40C4001-C-74 4000 70 1170 7339 6605 34.8 40.7 180
BXRC-40C4001-D-74 4000 70 1050 5489 4940 29.0 30.5 180
BXRC-40E4000-B-7x 4000 80 900 5194 4674 34.8 31.3 166
BXRC-40E4000-C-7x 4000 80 1170 6752 6077 34.8 40.7 166
BXRC-40E4000-D-7x 4000 80 1050 5050 4545 29.0 30.5 166
BXRC-40G4000-B-7x 4000 90 900 4452 4007 34.8 31.3 142
BXRC-40G4000-C-7x 4000 90 1170 5787 5209 34.8 40.7 142
BXRC-40G4000-D-7x 4000 90 1050 4328 3895 29.0 30.5 142
BXRC-40A4001-B-738,9 4000 97 900 3821 3439 34.8 31.3 122
BXRC-40A4001-C-738,9 4000 97 1170 4967 4471 34.8 40.7 122
BXRC-40A4001-D-738,9 4000 97 1050 3715 3343 29.0 30.5 122
BXRC-50C4001-B-7x 4000 93 900 4322 3890 34.8 31.3 138
BXRC-50C4001-C-7x 4000 93 1170 5619 5057 34.8 40.7 138
BXRC-50C4001-D-7x 4000 93 1050 4202 3782 29.0 30.5 138
BXRC-50E4001-B-7x 5000 80 900 5355 4820 34.8 31.3 171
BXRC-50E4001-C-7x 5000 80 1170 6962 6265 34.8 40.7 171
BXRC-50E4001-D-7x 5000 80 1050 5206 4686 29.0 30.5 171
BXRC-50G4001-B-7x 5000 90 900 4549 4094 34.8 31.3 145
BXRC-50G4001-C-7x 5000 90 1170 5913 5322 34.8 40.7 145
BXRC-50G4001-D-7x 5000 90 1050 4422 3980 29.0 30.5 145
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all
other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products
is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
5
Product Selection Guide
Table 1: Selection Guide, Pulsed Measurement Data (Tj = Tc = 25°C) (continued)
Part Number
Nominal
CCT1
(K)
CRI2
Nominal Drive
Current3
(mA)
Typical Pulsed
Flux4,5,6
Tc = 25ºC
(lm)
Minimum
Pulsed Flux6,7
Tc = 25ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-56G4000-B-74 5600 90 900 4774 4297 34.8 31.3 152
BXRC-56G4000-C-74 5600 90 1170 6207 5586 34.8 40.7 152
BXRC-56G400x-D-74 5600 90 1050 4642 4178 29.0 30.5 152
BXRC-56H4000-D-74 5600 97 1050 4015 3613 29.0 30.5 132
BXRC-57C4001-B-7x 5700 70 900 5516 4965 34.8 31.3 176
BXRC-57C4001-C-7x 5700 70 1170 7171 6454 34.8 40.7 176
BXRC-57C4001-D-7x 5700 70 1050 5363 4827 29.0 30.5 176
BXRC-57E4001-B-7x 5700 80 900 5293 4764 34.8 31.3 169
BXRC-57E4001-C-7x 5700 80 1170 6881 6193 34.8 40.7 169
BXRC-57E4001-D-7x 5700 80 1050 5146 4631 29.0 30.5 169
BXRC-65C4001-B-7x 6500 70 900 5613 5052 34.8 31.3 179
BXRC-65C4001-C-7x 6500 70 1170 7297 6567 34.8 40.7 179
BXRC-65C4001-D-7x 6500 70 1050 5457 4912 29.0 30.5 179
BXRC-65E4001-B-7x 6500 80 900 5387 4848 34.8 31.3 172
BXRC-65E4001-C-7x 6500 80 1170 7003 6303 34.8 40.7 172
BXRC-65E4001-D-7x 6500 80 1050 5237 4714 29.0 30.5 172
Notes for Table 1:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A products. CRI values are minimums for all
other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50, the minimum R9 value for 97 CRI products
is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Minimum flux values at the nominal test current are guaranteed by 100% test.
8. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
9. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
6
Product Selection Guide
Table 2: Selection Guide, Stabilized DC Performance (Tc = 70°C) 7,8
Part Number
Nominal
CCT1
(K)
GAI2 CRI3
Nominal
Drive
Current4
(mA)
Typical DC
Flux5,6
Tc = 70ºC
(lm)
Minimum DC
Flux6,9
Tc = 70ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-30A4001-B-73 3000 80 93 900 3495 3146 34.3 30.9 112
BXRC-30A4001-C-73 3000 80 93 1170 4544 4090 34.3 40.2 112
BXRC-30A4001-D-73 3000 80 93 1050 3398 3058 28.5 29.9 112
BXRC-35A4001-B-73 3500 80 93 900 3757 3382 34.3 30.9 120
BXRC-35A4001-C-73 3500 80 93 1170 4885 4396 34.3 40.2 120
BXRC-35A4001-D-73 3500 80 93 1050 3653 3288 28.5 29.9 120
BXRC-40A4001-B-73 4000 80 93 900 4020 3618 34.3 30.9 129
BXRC-40A4001-C-73 4000 80 93 1170 5225 4703 34.3 40.2 129
BXRC-40A4001-D-73 4000 80 93 1050 3908 3517 28.5 29.9 129
Notes for Table 2:
1. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
2. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary depending on
fixture design and performance.
3. CRI Values are specified as typical.
4. Drive current is referred to as nominal drive current.
5. Typical performance values are provided as a reference only and are not a guarantee of performance.
6. Bridgelux maintains a ±7% tolerance on flux measurements.
7. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
8. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface material
and the case temperature maintained at specified temperature. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
9. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number Nominal CCT1
(K) CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-17E4000-B-74 1750 80 900 2497 2247 33.9 30.5 82
BXRC-17E4000-C-74 1750 80 1170 3261 2935 33.9 39.7 82
BXRC-17E4000-D-74 1750 80 1050 2439 2195 28.1 29.5 83
BXRC-20B4001-C-73 2000 65 1170 5473 4926 33.9 39.7 138
BXRC-20B4001-D-73 2000 65 1050 4093 3684 28.1 29.5 139
BXRC-25E4000-B-74 2500 80 900 4036 3632 33.9 30.5 132
BXRC-25E4000-C-74 2500 80 1170 5246 4722 33.9 39.7 132
BXRC-25E4000-D-74 2500 80 1050 3924 3531 28.1 29.5 133
BXRC-27E4000-B-7x 2700 80 900 4326 3893 33.9 30.5 142
BXRC-27E4000-C-7x 2700 80 1170 5624 5061 33.9 39.7 142
BXRC-27E4000-D-7x 2700 80 1050 4206 3785 28.1 29.5 143
BXRC-27G40H0-B-7x 2700 90 900 3749 3374 33.9 30.5 123
BXRC-27G40H0-C-7x 2700 90 1170 4874 4386 33.9 39.7 123
BXRC-27G40H0-D-7x 2700 90 1050 3645 3280 28.1 29.5 124
BXRC-27G4000-B-7x 2700 90 900 3600 3240 33.9 30.5 118
BXRC-27G4000-C-7x 2700 90 1170 4680 4212 33.9 39.7 118
BXRC-27G4000-D-7x 2700 90 1050 3500 3150 28.1 29.5 119
BXRC-27H4000-B-7x 2700 97 900 3136 2822 33.9 30.5 103
BXRC-27H4000-C-7x 2700 97 1170 4076 3669 33.9 39.7 103
BXRC-27H4000-D-7x 2700 97 1050 3049 2744 28.1 29.5 103
BXRC-30C4001-B-74 3000 70 900 4961 4465 33.9 30.5 163
BXRC-30C4001-C-74 3000 70 1170 6449 5804 33.9 39.7 163
BXRC-30C4001-D-74 3000 70 1050 4823 4341 28.1 29.5 163
BXRC-30E4000-B-7x 3000 80 900 4500 4050 33.9 30.5 147
BXRC-30E4000-C-7x 3000 80 1170 5850 5265 33.9 39.7 147
BXRC-30E4000-D-7x 3000 80 1050 4375 3938 28.1 29.5 148
BXRC-30G40H0-B-7x 3000 90 900 3918 3526 33.9 30.5 128
BXRC-30G40H0-C-7x 3000 90 1170 5094 4584 33.9 39.7 128
BXRC-30G40H0-D-7x 3000 90 1050 3809 3428 28.1 29.5 129
BXRC-30G4000-B-7x 3000 90 900 3745 3371 33.9 30.5 123
BXRC-30G4000-C-7x 3000 90 1170 4869 4382 33.9 39.7 123
BXRC-30G4000-D-7x 3000 90 1050 3641 3277 28.1 29.5 123
BXRC-30G400C-B-73 3000 90 900 3484 3136 33.9 30.5 114
BXRC-30G400C-D-73 3000 90 1050 3387 3049 28.1 29.5 115
BXRC-30H4000-B-7x 3000 97 900 3339 3005 33.9 30.5 109
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50,
the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
8
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5 (continued)
Part Number Nominal CCT1
(K) CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-30H4000-C-7x 3000 97 1170 4341 3906 33.9 39.7 109
BXRC-30H4000-D-7x 3000 97 1050 3246 2922 28.1 29.5 110
BXRC-30A4001-B-738,9 3000 93 900 3383 3044 33.9 30.5 111
BXRC-30A4001-C-738,9 3000 93 1170 4397 3958 33.9 39.7 111
BXRC-30A4001-D-738,9 3000 93 1050 3289 2960 28.1 29.5 111
BXRC-35E4000-B-7x 3500 80 900 4645 4181 33.9 30.5 152
BXRC-35E4000-C-7x 3500 80 1170 6039 5435 33.9 39.7 152
BXRC-35E4000-D-7x 3500 80 1050 4516 4065 28.1 29.5 153
BXRC-35G4000-B-7x 3500 90 900 3861 3475 33.9 30.5 127
BXRC-35G4000-C-7x 3500 90 1170 5020 4518 33.9 39.7 127
BXRC-35G4000-D-7x 3500 90 1050 3754 3379 28.1 29.5 127
BXRC-35A4001-B-738,9 3500 93 900 3636 3273 33.9 30.5 119
BXRC-35A4001-C-738,9 3500 93 1170 4727 4254 33.9 39.7 119
BXRC-35A4001-D-738,9 3500 93 1050 3535 3182 28.1 29.5 120
BXRC-40C4001-B-74 4000 70 900 5081 4573 33.9 30.5 167
BXRC-40C4001-C-74 4000 70 1170 6605 5945 33.9 39.7 167
BXRC-40C4001-D-74 4000 70 1050 4940 4446 28.1 29.5 167
BXRC-40E4000-B-7x 4000 80 900 4674 4207 33.9 30.5 153
BXRC-40E4000-C-7x 4000 80 1170 6077 5469 33.9 39.7 153
BXRC-40E4000-D-7x 4000 80 1050 4545 4090 28.1 29.5 154
BXRC-40G4000-B-7x 4000 90 900 4007 3606 33.9 30.5 131
BXRC-40G4000-C-7x 4000 90 1170 5209 4688 33.9 39.7 131
BXRC-40G4000-D-7x 4000 90 1050 3895 3506 28.1 29.5 132
BXRC-40H4000-B-7x 4000 97 900 3439 3095 33.9 30.5 113
BXRC-40H4000-C-7x 4000 97 1170 4471 4024 33.9 39.7 113
BXRC-40H4000-D-7x 4000 97 1050 3343 3009 28.1 29.5 113
BXRC-40A4001-B-737,8 4000 93 900 3890 3501 33.9 30.5 127
BXRC-40A4001-C-737,8 4000 93 1170 5057 4551 33.9 39.7 127
BXRC-40A4001-D-737,8 4000 93 1050 3782 3404 28.1 29.5 128
BXRC-50C4001-B-74 5000 70 900 5139 4625 33.9 30.5 168
BXRC-50C4001-C-74 5000 70 1170 6681 6013 33.9 39.7 168
BXRC-50C4001-D-74 5000 70 1050 4996 4497 28.1 29.5 169
BXRC-50E4001-B-74 5000 80 900 4820 4338 33.9 30.5 158
BXRC-50E4001-C-74 5000 80 1170 6265 5639 33.9 39.7 158
BXRC-50E4001-D-74 5000 80 1050 4686 4217 28.1 29.5 159
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50,
the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
9
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number Nominal CCT1
(K) CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRC-50G4001-B-7x 5000 90 900 4094 3684 33.9 30.5 134
BXRC-50G4001-C-7x 5000 90 1170 5322 4790 33.9 39.7 134
BXRC-50G4001-D-7x 5000 90 1050 3980 3582 28.1 29.5 135
BXRC-56G4000-B-74 5600 90 900 4297 3867 33.9 30.5 141
BXRC-56G4000-C-74 5600 90 1170 5586 5027 33.9 39.7 141
BXRC-56G400x-D-74 5600 90 1050 4178 3760 28.1 29.5 142
BXRC-56H4000-D-74 5600 97 1050 3613 3252 28.1 29.5 122
BXRC-57C4001-B-7x 5700 70 900 4965 4468 33.9 30.5 163
BXRC-57C4001-C-7x 5700 70 1170 6454 5809 33.9 39.7 163
BXRC-57C4001-D-7x 5700 70 1050 4827 4344 28.1 29.5 164
BXRC-57E4001-B-7x 5700 80 900 4764 4287 33.9 30.5 156
BXRC-57E4001-C-7x 5700 80 1170 6193 5574 33.9 39.7 156
BXRC-57E4001-D-7x 5700 80 1050 4631 4168 28.1 29.5 157
BXRC-65C4001-B-7x 6500 70 900 5052 4547 33.9 30.5 166
BXRC-65C4001-C-7x 6500 70 1170 6567 5911 33.9 39.7 166
BXRC-65C4001-D-7x 6500 70 1050 4912 4420 28.1 29.5 166
BXRC-65E4001-B-7x 6500 80 900 4848 4364 33.9 30.5 159
BXRC-65E4001-C-7x 6500 80 1170 6303 5673 33.9 39.7 159
BXRC-65E4001-D-7x 6500 80 1050 4714 4242 28.1 29.5 160
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Decor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 value for 90 CRI products is 50,
the minimum R9 value for 97 CRI products is 93. Bridgelux maintains a ±3 tolerance for all CRI and R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux
test setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may
vary depending on fixture design and performance.
10
Performance at Commonly Used Drive Currents
Vero LED arrays are tested to the specifications shown using the nominal drive currents in Table 1. Vero may also
be driven at other drive currents dependent on specific application design requirements. The performance at any
drive current can be derived from the current vs. voltage characteristics shown in Figures 1, 2 & 3 and the flux vs. current
characteristics shown in Figures 4, 5 & 6. The performance at commonly used drive currents is summarized in Table 4.
Table 4: Product Performance at Commonly Used Drive Currents
Part Number CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
BXRC-17E4000-B-7x 80
450 33.2 14.9 1490 1338 100
600 34.0 20.4 1954 1753 96
900 34.8 31.3 2774 2497 89
1350 35.6 48.1 4126 3636 86
1800 36.1 65.1 5310 4616 82
BXRC-17E4000-C-7x 80
585 33.2 19.4 1946 1748 100
780 34.0 26.5 2552 2289 96
1170 34.8 40.7 3624 3261 89
1755 35.6 62.5 5390 4749 86
2340 36.1 84.6 6935 6029 82
BXRC-17E4000-D-7x 80
525 27.7 14.6 1455 1307 100
700 28.2 19.8 1909 1712 97
1050 29.0 30.5 2710 2439 89
1575 30.4 47.9 4031 3551 84
2100 31.5 66.2 5187 4509 78
BXRC-20B4001-C-73 65
585 33.2 19.4 3265 2934 168
780 34.0 26.5 4283 3841 161
1170 34.8 40.7 6081 5473 149
1755 35.6 62.5 9044 7969 145
2340 36.1 84.6 11638 10117 138
BXRC-20B4001-D-73 65
525 27.7 14.6 2442 2194 168
700 28.2 19.8 3203 2873 162
1050 29.0 30.5 4548 4093 149
1575 30.4 47.9 6764 5960 141
2100 31.5 66.2 8704 7566 131
BXRC-25E4000-B-74 80
450 33.2 14.9 2408 2163 161
600 34.0 20.4 3158 2833 155
900 34.8 31.3 4484 4036 143
1350 35.6 48.1 6669 5876 139
1800 36.1 65.1 8582 7460 132
BXRC-25E4000-C-74 80
585 33.2 19.4 3130 2812 161
780 34.0 26.5 4106 3682 155
1170 34.8 40.7 5829 i102 143
1755 35.6 62.5 8670 7639 139
2340 36.1 84.6 11157 9698 132
BXRC-25E4000-D-74 80
525 27.7 14.6 2341 2103 161
700 28.2 19.8 3070 2754 155
1050 29.0 30.5 4360 3924 143
1575 30.4 47.9 6484 5713 135
2100 31.5 66.2 8344 7253 126
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
11
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
BXRC-27E4000-B-7x 80
450 33.2 14.9 2581 2319 173
600 34.0 20.4 3385 3036 166
900 34.8 31.3 4807 4326 153
1350 35.6 48.1 7149 6299 149
1800 36.1 65.1 9200 7997 141
BXRC-27E4000-C-7x 80
585 33.2 19.4 3265 3090 168
780 34.0 26.5 4278 3965 161
1170 34.8 40.7 6249 5624 153
1755 35.6 62.5 8989 7912 144
2340 36.1 84.6 11531 9938 136
BXRC-27E4000-D-7x 80
525 27.7 14.6 2489 2311 171
700 28.2 19.8 3237 2967 164
1050 29.0 30.5 4673 4206 153
1575 30.4 47.9 6675 5902 139
2100 31.5 66.2 8497 7389 128
BXRC-27G40H0-B-7x 90
450 33.2 14.9 2236 2010 150
600 34.0 20.4 2934 2631 144
900 34.8 31.3 4166 3749 133
1350 35.6 48.1 6195 5459 129
1800 36.1 65.1 7972 6930 123
BXRC-27G40H0-C-7x 90
585 33.2 19.4 2829 2678 146
780 34.0 26.5 3708 3436 140
1170 34.8 40.7 5415 4874 133
1755 35.6 62.5 7790 6857 125
2340 36.1 84.6 9993 8613 118
BXRC-27G40H0-D-7x 90
525 27.7 14.6 2157 2002 148
700 28.2 19.8 2805 2571 142
1050 29.0 30.5 4050 3645 133
1575 30.4 47.9 5785 5115 121
2100 31.5 66.2 7364 6404 111
BXRC-27G4000-B-7x 90
450 33.2 14.9 2148 1930 144
600 34.0 20.4 2817 2527 138
900 34.8 31.3 4000 3600 128
1350 35.6 48.1 5949 5242 124
1800 36.1 65.1 7656 6655 118
BXRC-27G4000-C-7x 90
585 33.2 19.4 2717 2571 140
780 34.0 26.5 3561 3300 134
1170 34.8 40.7 5200 4680 128
1755 35.6 62.5 7481 6585 120
2340 36.1 84.6 9596 8271 113
BXRC-27G4000-D-7x 90
525 27.7 14.6 2072 1923 142
700 28.2 19.8 2694 2469 136
1050 29.0 30.5 3889 3500 128
1575 30.4 47.9 5555 4912 116
2100 31.5 66.2 7072 6149 107
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
12
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
BXRC-27H4000-B-7x 97
450 33.2 14.9 1871 1723 125
600 34.0 20.4 2454 2212 120
900 34.8 31.3 3484 3136 111
1350 35.6 48.1 5182 4401 108
1800 36.1 65.1 6668 5509 102
BXRC-27H4000-C-7x 97
585 33.2 19.4 2366 2239 122
780 34.0 26.5 3101 2875 117
1170 34.8 40.7 4529 4076 111
1755 35.6 62.5 6516 5721 104
2340 36.1 84.6 8358 7162 99
BXRC-27H4000-D-7x 97
525 27.7 14.6 1804 1675 124
700 28.2 19.8 2346 2150 119
1050 29.0 30.5 3387 3049 111
1575 30.4 47.9 4838 4278 101
2100 31.5 66.2 6159 5356 93
BXRC-30C4001-B-74 70
450 33.2 14.9 2960 2726 198
600 34.0 20.4 3882 3499 190
900 34.8 31.3 5512 4961 176
1350 35.6 48.1 8198 6962 170
1800 36.1 65.1 10550 8716 162
BXRC-30C4001-C-74 70
585 33.2 19.4 3744 3543 193
780 34.0 26.5 4906 4549 185
1170 34.8 40.7 7166 6449 176
1755 35.6 62.5 10309 9051 165
2340 36.1 84.6 13224 11331 156
BXRC-30C4001-D-74 70
525 27.7 14.6 2855 2650 196
700 28.2 19.8 3712 3402 188
1050 29.0 30.5 5359 4823 176
1575 30.4 47.9 7655 6769 160
2100 31.5 66.2 9745 8474 147
BXRC-30E4000-B-7x 80
450 33.2 14.9 2685 2412 180
600 34.0 20.4 3522 3159 173
900 34.8 31.3 5000 4500 160
1350 35.6 48.1 7437 6553 155
1800 36.1 65.1 9570 8319 147
BXRC-30E4000-C-7x 80
585 33.2 19.4 3396 3214 175
780 34.0 26.5 4451 4124 168
1170 34.8 40.7 6500 5850 160
1755 35.6 62.5 9351 8231 150
2340 36.1 84.6 11995 10339 142
BXRC-30E4000-D-7x 80
525 27.7 14.6 2590 2404 178
700 28.2 19.8 3367 3086 170
1050 29.0 30.5 4861 4375 160
1575 30.4 47.9 6944 6140 145
2100 31.5 66.2 8839 7687 133
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Performance at Commonly Used Drive Currents
13
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
BXRC-30G40H0-B-7x 90
450 33.2 14.9 2337 2100 156
600 34.0 20.4 3066 2750 150
900 34.8 31.3 4353 3918 139
1350 35.6 48.1 6475 5705 135
1800 36.1 65.1 8332 7243 128
BXRC-30G40H0-C-7x 90
585 33.2 19.4 2957 2798 152
780 34.0 26.5 3875 3591 146
1170 34.8 40.7 5660 5094 139
1755 35.6 62.5 8142 7166 130
2340 36.1 84.6 10444 9001 123
BXRC-30G40H0-D-7x 90
525 27.7 14.6 2255 2093 155
700 28.2 19.8 2932 2687 148
1050 29.0 30.5 4233 3809 139
1575 30.4 47.9 6046 5346 126
2100 31.5 66.2 7696 6693 116
BXRC-30G4000-B-7x 90
450 33.2 14.9 2234 2008 149
600 34.0 20.4 2931 2629 144
900 34.8 31.3 4161 3745 133
1350 35.6 48.1 6189 5453 129
1800 36.1 65.1 7965 6923 122
BXRC-30G4000-C-7x 90
585 33.2 19.4 2827 2675 145
780 34.0 26.5 3704 3433 140
1170 34.8 40.7 5410 4869 133
1755 35.6 62.5 7783 6850 124
2340 36.1 84.6 9983 8604 118
BXRC-30G4000-D-7x 90
525 27.7 14.6 2155 2000 148
700 28.2 19.8 2803 2568 142
1050 29.0 30.5 4046 3641 133
1575 30.4 47.9 5779 5110 121
2100 31.5 66.2 7357 6397 111
BXRC-30G400C-B-73 90
450 33.2 14.9 2078 1868 139
600 34.0 20.4 2726 2445 134
900 34.8 31.3 3871 3484 124
1350 35.6 48.1 5758 5073 120
1800 36.1 65.1 7409 6440 114
BXRC-30G400C-D-73 90
525 27.7 14.6 2005 1861 138
700 28.2 19.8 2607 2389 132
1050 29.0 30.5 3764 3387 124
1575 30.4 47.9 5376 4754 112
2100 31.5 66.2 6843 5951 103
BXRC-30H4000-B-7x 97
450 33.2 14.9 1992 1834 133
600 34.0 20.4 2613 2355 128
900 34.8 31.3 3710 3339 118
1350 35.6 48.1 5518 4686 115
1800 36.1 65.1 7100 5866 109
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
14
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
BXRC-30H4000-C-7x 97
585 33.2 19.4 2520 2385 130
780 34.0 26.5 3302 3062 124
1170 34.8 40.7 4823 4341 118
1755 35.6 62.5 6938 6091 111
2340 36.1 84.6 8900 7626 105
BXRC-30H4000-D-7x 97
525 27.7 14.6 1921 1783 132
700 28.2 19.8 2498 2290 126
1050 29.0 30.5 3607 3246 118
1575 30.4 47.9 5152 4556 107
2100 31.5 66.2 6558 5703 99
BXRC-30A4001-B-73 93
450 33.3 15.0 2018 1813 135
600 33.9 20.4 2647 2374 130
900 35.0 31.2 3758 3383 120
1350 36.7 49.5 5590 4925 113
1800 38.0 68.4 7193 6253 105
BXRC-30A4001-C-73 93
585 33.4 19.5 2553 2416 131
780 34.0 26.5 3345 3100 126
1170 35.0 40.6 4886 4397 120
1755 36.8 64.5 7029 6187 109
2340 38.1 89.3 9016 7771 101
BXRC-30A4001-D-73 93
525 27.7 14.6 1947 1807 134
700 28.2 19.8 2531 2320 128
1050 29.0 30.4 3654 3289 120
1575 30.4 47.9 5219 4615 109
2100 31.5 66.2 6644 5778 100
BXRC-35E4000-B-7x 80
450 33.2 14.9 2771 2490 185
600 34.0 20.4 3635 3261 178
900 34.8 31.3 5162 4645 165
1350 35.6 48.1 7677 6764 160
1800 36.1 65.1 9879 8587 152
BXRC-35E4000-C-7x 80
585 33.2 19.4 3506 3318 180
780 34.0 26.5 4594 4257 173
1170 34.8 40.7 6710 6039 165
1755 35.6 62.5 9653 8496 154
2340 36.1 84.6 12382 10672 146
BXRC-35E4000-D-7x 80
525 27.7 14.6 2673 2481 184
700 28.2 19.8 3476 3186 176
1050 29.0 30.5 5018 4516 165
1575 30.4 47.9 7168 6338 150
2100 31.5 66.2 9125 7935 138
BXRC-35G4000-B-7x 90
450 33.2 14.9 2304 2070 154
600 34.0 20.4 3022 2710 148
900 34.8 31.3 4291 3861 137
1350 35.6 48.1 6381 5623 133
1800 36.1 65.1 8212 7138 126
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
15
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
BXRC-35G4000-C-7x 90
585 33.2 19.4 2914 2758 150
780 34.0 26.5 3819 3539 144
1170 34.8 40.7 5578 5020 137
1755 35.6 62.5 8024 7062 128
2340 36.1 84.6 10293 8871 122
BXRC-35G4000-D-7x 90
525 27.7 14.6 2222 2063 153
700 28.2 19.8 2889 2648 146
1050 29.0 30.5 4171 3754 137
1575 30.4 47.9 5958 5269 124
2100 31.5 66.2 7585 6596 115
BXRC-35A4001-B-73 80
450 33.2 14.9 2169 1949 145
600 34.0 20.4 2846 2552 139
900 34.8 31.3 4040 3636 129
1350 35.6 48.1 6009 5295 125
1800 36.1 65.1 7733 6722 119
BXRC-35A4001-C-73 80
585 33.2 19.4 2744 2597 141
780 34.0 26.5 3596 3333 136
1170 34.8 40.7 5252 4727 129
1755 35.6 62.5 7556 6651 121
2340 36.1 84.6 9692 8354 115
BXRC-35A4001-D-73 80
525 27.7 14.6 2092 1942 144
700 28.2 19.8 2721 2494 138
1050 29.0 30.5 3928 3535 129
1575 30.4 47.9 5611 4961 117
2100 31.5 66.2 7142 6211 108
BXRC-40C4001-B-74 80
450 33.2 14.9 2169 1949 145
600 34.0 20.4 2846 2552 139
900 34.8 31.3 4040 3636 129
1350 35.6 48.1 6009 5295 125
1800 36.1 65.1 7733 6722 119
BXRC-40C4001-C-74 80
585 33.2 19.4 2744 2597 141
780 34.0 26.5 3596 3333 136
1170 34.8 40.7 5252 4727 129
1755 35.6 62.5 7556 6651 121
2340 36.1 84.6 9692 8354 115
BXRC-40C4001-D-74 80
525 27.7 14.6 2092 1942 144
700 28.2 19.8 2721 2494 138
1050 29.0 30.5 3928 3535 129
1575 30.4 47.9 5611 4961 117
2100 31.5 66.2 7142 6211 108
BXRC-40E4000-B-7x 80
450 33.2 14.9 2789 2506 187
600 34.0 20.4 3658 3281 179
900 34.8 31.3 5194 4674 166
1350 35.6 48.1 7725 6806 161
1800 36.1 65.1 9940 8641 153
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
16
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
BXRC-40E4000-C-7x 80
585 33.2 19.4 3528 3339 182
780 34.0 26.5 4623 4284 174
1170 34.8 40.7 6752 6077 166
1755 35.6 62.5 9713 8549 155
2340 36.1 84.6 12459 10739 147
BXRC-40E4000-D-7x 80
525 27.7 14.6 2690 2497 185
700 28.2 19.8 3498 3205 177
1050 29.0 30.5 5050 4545 166
1575 30.4 47.9 7213 6378 150
2100 31.5 66.2 9182 7984 139
BXRC-40G4000-B-7x 90
450 33.2 14.9 2390 2148 160
600 34.0 20.4 3135 2812 154
900 34.8 31.3 4452 4007 142
1350 35.6 48.1 6621 5834 138
1800 36.1 65.1 8520 7407 131
BXRC-40G4000-C-7x 90
585 33.2 19.4 3024 2862 156
780 34.0 26.5 3962 3672 149
1170 34.8 40.7 5787 5209 142
1755 35.6 62.5 8326 7328 133
2340 36.1 84.6 10680 9205 126
BXRC-40G4000-D-7x 90
525 27.7 14.6 2306 2140 158
700 28.2 19.8 2998 2748 152
1050 29.0 30.5 4328 3895 142
1575 30.4 47.9 6182 5467 129
2100 31.5 66.2 7870 6844 119
BXRC-40H4000-B-7x 97
450 33.2 14.9 2052 1843 137
600 34.0 20.4 2691 2414 132
900 34.8 31.3 3821 3439 122
1350 35.6 48.1 5683 5007 118
1800 36.1 65.1 7313 6357 112
BXRC-40H4000-C-7x 97
585 33.2 19.4 2595 2456 134
780 34.0 26.5 3401 3152 128
1170 34.8 40.7 4967 4471 122
1755 35.6 62.5 7146 6290 114
2340 36.1 84.6 9166 7900 108
BXRC-40H4000-D-7x 97
525 27.7 14.6 1979 1837 136
700 28.2 19.8 2573 2358 130
1050 29.0 30.5 3715 3343 122
1575 30.4 47.9 5306 4692 111
2100 31.5 66.2 6755 5874 102
BXRC-40A4001-B-73 80
450 33.2 14.9 2321 2085 155
600 34.0 20.4 3044 2730 149
900 34.8 31.3 4322 3890 138
1350 35.6 48.1 6428 5664 134
1800 36.1 65.1 8272 7191 127
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
17
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
BXRC-40A4001-C-73 80
585 33.2 19.4 2936 2778 151
780 34.0 26.5 3847 3565 145
1170 34.8 40.7 5619 5057 138
1755 35.6 62.5 8083 7115 129
2340 36.1 84.6 10368 8937 123
BXRC-40A4001-D-73 80
525 27.7 14.6 2238 2078 154
700 28.2 19.8 2911 2667 147
1050 29.0 30.5 4202 3782 138
1575 30.4 47.9 6002 5307 125
2100 31.5 66.2 7641 6644 115
BXRC-50C4001-B-74 70
450 33.2 14.9 3066 2755 205
600 34.0 20.4 4022 3607 197
900 34.8 31.3 5710 5139 182
1350 35.6 48.1 8492 7483 177
1800 36.1 65.1 10928 9500 168
BXRC-50C4001-C-74 70
585 33.2 19.4 3878 3670 200
780 34.0 26.5 5082 4710 192
1170 34.8 40.7 7423 6681 182
1755 35.6 62.5 10679 9399 171
2340 36.1 84.6 13698 11806 162
BXRC-50C4001-D-74 70
525 27.7 14.6 2957 2745 203
700 28.2 19.8 3845 3524 195
1050 29.0 30.5 5551 4996 182
1575 30.4 47.9 7929 7012 165
2100 31.5 66.2 10094 8778 152
BXRC-50E4001-B-74 80
450 33.2 14.9 2875 2584 192
600 34.0 20.4 3772 3383 185
900 34.8 31.3 5355 4820 171
1350 35.6 48.1 7965 7018 166
1800 36.1 65.1 10249 8909 158
BXRC-50E4001-C-7x 80
585 33.2 19.4 3637 3442 187
780 34.0 26.5 4766 4417 180
1170 34.8 40.7 6962 6265 171
1755 35.6 62.5 10015 8815 160
2340 36.1 84.6 12846 11072 152
BXRC-50E4001-D-7x 80
525 27.7 14.6 2773 2574 190
700 28.2 19.8 3606 3305 183
1050 29.0 30.5 5206 4686 171
1575 30.4 47.9 7437 6576 155
2100 31.5 66.2 9467 8232 143
BXRC-50G4001-B-7x 90
450 33.2 14.9 2442 2194 163
600 34.0 20.4 3204 2873 157
900 34.8 31.3 4549 4094 145
1350 35.6 48.1 6765 5961 141
1800 36.1 65.1 8706 7568 134
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
18
Performance at Commonly Used Drive Currents
Part Number CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
BXRC-50G4001-C-7x 90
585 33.2 19.4 3090 2924 159
780 34.0 26.5 4049 3752 153
1170 34.8 40.7 5913 5322 145
1755 35.6 62.5 8507 7487 136
2340 36.1 84.6 10912 9405 129
BXRC-50G4001-D-7x 90
525 27.7 14.6 2356 2187 162
700 28.2 19.8 3063 2807 155
1050 29.0 30.5 4422 3980 145
1575 30.4 47.9 6317 5586 132
2100 31.5 66.2 8041 6992 121
BXRC-56G4000-B-74 90
450 33.2 14.9 2543 2361 170
600 34.0 20.4 3307 3031 162
900 34.8 31.3 4774 4297 152
1350 35.6 48.1 6820 6030 142
1800 36.1 65.1 8681 7549 133
BXRC-56G4000-C-74 90
585 33.2 19.4 3306 3069 170
780 34.0 26.5 4299 3940 162
1170 34.8 40.7 6207 5586 152
1755 35.6 62.5 8865 7839 142
2340 36.1 84.6 11286 9814 133
BXRC-56G400x-D-74 90
525 27.7 14.6 2473 2295 170
700 28.2 19.8 3215 2947 163
1050 29.0 30.5 4642 4178 152
1575 30.4 47.9 6630 5863 138
2100 31.5 66.2 8440 7340 127
BXRC-56H4000-D-74 97
525 27.7 14.6 2139 1985 147
700 28.2 19.8 2781 2548 141
1050 29.0 30.5 4015 3613 132
1575 30.4 47.9 5734 5071 120
2100 31.5 66.2 7300 6348 110
BXRC-57C4001-B-7x 70
450 33.2 14.9 2962 2661 198
600 34.0 20.4 3885 3485 190
900 34.8 31.3 5516 4965 176
1350 35.6 48.1 8205 7229 171
1800 36.1 65.1 10558 9178 162
BXRC-57C4001-C-7x 70
585 33.2 19.4 3747 3546 193
780 34.0 26.5 4910 4550 185
1170 34.8 40.7 7171 6454 176
1755 35.6 62.5 10317 9080 165
2340 36.1 84.6 13233 11406 156
BXRC-57C4001-D-7x 70
525 27.7 14.6 2857 2652 196
700 28.2 19.8 3715 3405 188
1050 29.0 30.5 5363 4827 176
1575 30.4 47.9 7661 6774 160
2100 31.5 66.2 9752 8480 147
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
19
Performance at Commonly Used Drive Currents
Table 4: Product Performance at Commonly Used Drive Currents (Continued)
Part Number CRI
Drive
Current1
(mA)
Typical Vf
Tc = 25ºC
(V)
Typical
Power
Tc = 25ºC
(W)
Typical
Flux2
Tc = 25ºC
(lm)
Typical
DC Flux3
Tc = 85ºC
(lm)
Typical
Efficacy
Tc = 25ºC
(lm/W)
BXRC-57E4001-B-7x 80
450 33.2 14.9 2842 2554 190
600 34.0 20.4 3728 3344 183
900 34.8 31.3 5293 4764 169
1350 35.6 48.1 7872 6936 164
1800 36.1 65.1 10130 8806 156
BXRC-57E4001-C-7x 80
585 33.2 19.4 3595 3402 185
780 34.0 26.5 4711 4366 178
1170 34.8 40.7 6881 6193 169
1755 35.6 62.5 9899 8713 158
2340 36.1 84.6 12698 10944 150
BXRC-57E4001-D-7x 80
525 27.7 14.6 2741 2544 188
700 28.2 19.8 3565 3267 180
1050 29.0 30.5 5146 4631 169
1575 30.4 47.9 7350 6500 153
2100 31.5 66.2 9357 8137 141
BXRC-65C4001-B-7x 70
450 33.2 14.9 3014 2708 202
600 34.0 20.4 3953 3546 194
900 34.8 31.3 5613 5052 179
1350 35.6 48.1 8348 7356 174
1800 36.1 65.1 10743 9339 165
BXRC-65C4001-C-7x 70
585 33.2 19.4 3813 3608 196
780 34.0 26.5 4996 4630 188
1170 34.8 40.7 7297 6567 179
1755 35.6 62.5 10498 9240 168
2340 36.1 84.6 13466 11606 159
BXRC-65C4001-D-7x 70
525 27.7 14.6 2907 2698 200
700 28.2 19.8 3780 3464 191
1050 29.0 30.5 5457 4912 179
1575 30.4 47.9 7795 6893 163
2100 31.5 66.2 9923 8629 150
BXRC-65E4001-B-7x 80
450 33.2 14.9 2892 2599 194
600 34.0 20.4 3794 3403 186
900 34.8 31.3 5387 4848 172
1350 35.6 48.1 8012 7059 167
1800 36.1 65.1 10310 8962 158
BXRC-65E4001-C-7x 80
585 33.2 19.4 3659 3463 188
780 34.0 26.5 4795 4443 181
1170 34.8 40.7 7003 6303 172
1755 35.6 62.5 10075 8867 161
2340 36.1 84.6 12923 11138 153
BXRC-65E4001-D-7x 80
525 27.7 14.6 2790 2590 192
700 28.2 19.8 3628 3325 184
1050 29.0 30.5 5237 4714 172
1575 30.4 47.9 7481 6615 156
2100 31.5 66.2 9523 8281 144
Notes for Table 4:
1. Alternate drive currents are provided for reference only and are not a guarantee of performance.
2. Bridgelux maintains a ± 7% tolerance on flux measurements.
3. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
20
Electrical Characteristics
Table 5: Electrical Characteristics
Part Number Drive Current
(mA)
Forward Voltage
Pulsed, Tc = 25ºC (V) 1, 2, 3, 8 Typical
Coefficient
of Forward
Voltage4
Vf/Tc
(mV/ºC)
Typical
Thermal
Resistance
Junction
to Case5,6
Rj-c (ºC/W)
Driver Selection
Voltages7
(V)
Minimum Typical Maximum
Vf Min.
Hot
Tc = 105ºC
(V)
Vf Max.
Cold
Tc = -40ºC
(V)
BXRC-xxx400x-B-7x
900 32.2 34.8 37.4 -14.9 0.15 31.0 38.4
1800 33.4 36.1 38.8 -14.9 0.19 32.2 39.8
BXRC-xxx400x-C-7x
1170 32.2 34.8 37.4 -14.9 0.11 31.0 38.4
2340 33.4 36.1 38.8 -14.9 0.13 32.2 39.8
BXRC-xxx400x-D-7x
1050 26.8 29.0 31.2 -12.2 0.16 25.8 32.0
2100 29.2 31.5 33.9 -12.2 0.19 28.2 34.7
Notes for Table 5:
1. Parts are tested in pulsed conditions, Tc = 25°C. Pulse width is 10ms.
2. Voltage minimum and maximum are provided for reference only and are not a guarantee of performance.
3. Bridgelux maintains a tester tolerance of ± 0.10V on forward voltage measurements.
4. Typical coefficient of forward voltage tolerance is ± 0.1mV for nominal current.
5. Thermal resistance values are based from test data of a 3000K 80 CRI product.
6. Thermal resistance value was calculated using total electrical input power; optical power was not subtracted from input power. The thermal interface
material used during testing is not included in the thermal resistance value.
7. Vf min hot and max cold values are provided as reference only and are not guaranteed by test. These values are provided to aid in driver design and
selection over the operating range of the product.
8. This product has been designed and manufactured per IEC 62031:2014. This product has passed dielectric withstand voltage testing at 1160 V. The
working voltage designated for the insulation is 80V d.c. The maximum allowable voltage across the array must be determined in the end product
application.
21
Eye Safety
Table 6: Eye Safety Risk Group (RG) Classifications
Part Number
Drive
Current 5
(mA)
CCT1,5
2700K/3000K 4000K25000K36500K4
BXRC-xxx400x-B-7x
900 RG1 RG1 RG1 RG1
1350 RG1 RG1 RG1 RG2
1800 RG1 RG1 RG2 RG2
BXRC-xxx400x-C-7x
1170 RG1 RG1 RG1 RG1
1755 RG1 RG1 RG2 RG2
2340 RG1 RG1 RG2 RG2
BXRC-xxx400x-D-7x
1050 RG1 RG1 RG1 RG1
1575 RG1 RG1 RG1 RG2
2100 RG1 RG1 RG2 RG2
Notes for Table 6:
1. Eye safety classification for the use of Bridgelux Vero Series LED arrays is in accordance with specification IEC/TR 62778: Application of IEC 62471 for the
assessment of blue light hazard to light sources and luminaires.
2. For products classified as RG2 at 4000K, Ethr= 1847.5 lx.
3. For products classified as RG2 at 5000K Ethr= 1315.8 lx.
4. For products classified as RG2 at 6500K, Ethr= 1124.5 lx.
5. Please contact your Bridgelux sales representative for Ethr values at specific drive currents and CCTs not listed.
22
Absolute Maximum Ratings
Parameter Maximum Rating
LED Junction Temperature (Tj)150°C
Storage Temperature -40°C to +105°C
Operating Case Temperature1 (Tc)105°C
Soldering Temperature2300°C or lower for a maximum of 6 seconds
BXRC-xxx400x-B-7x BXRC-xxx400x-C-7x BXRC-xxx400x-D-7x
Maximum Drive Current31800mA 2340mA 2100mA
Maximum Peak Pulsed Drive Current42570mA 3340mA 3000mA
Maximum Reverse Voltage5-60V -60V -50V
Notes for Table 7:
1. For IEC 62717 requirement, please consult your Bridgelux sales representative.
2. Refer to Bridgelux Application Note AN31: Assembly Considerations for Bridgelux Vero LED Arrays.
3. Arrays may be driven at higher currents however lumen maintenance may be reduced.
4. Bridgelux recommends a maximum duty cycle of 10% and pulse width of 20 ms when operating LED Arrays at maximum peak pulsed
current specified. Maximum peak pulsed currents indicate values where LED Arrays can be driven without catastrophic failures.
5. Light emitting diodes are not designed to be driven in reverse voltage and will not produce light under this condition. Maximum rating
provided for reference only.
Table 7: Maximum Ratings
23
Performance Curves
Figure 3: Vero 18D Drive Current vs. Voltage Figure 4: Vero 18B Typical Relative Flux vs. Current
Notes for Figures 1-6:
1. Bridgelux does not recommend driving high power LEDs at low currents. Doing so may produce unpredictable results. Pulse width modulation (PWM) is
recommended for dimming effects.
2. Products tested under pulsed condition (10ms pulse width) at nominal test current where Tj (junction temperature) = Tc (case temperature) = 25°C.
0
250
500
750
1000
1250
1500
1750
2000
2250
26 27 28 29 30 31 32
Forward Current (mA)
Forward Voltage (V)
0%
20%
40%
60%
80%
100%
120%
140%
160%
180%
200%
0200 400 600 800 1000 1200 1400 1600 1800 2000
Relative Luminous Flux
Forward Current (mA)
Figure 5: Vero 18C Typical Relative Flux vs. Current Figure 6 Vero 18D Typical Relative Flux vs. Current
0%
20%
40%
60%
80%
100%
120%
140%
160%
180%
200%
100 400 700 1000 1300 1600 1900 2200 2500
Relative Luminous Flux
Forward Current (mA)
y = -7E-08x2+ 0.001x + 0.027
0%
20%
40%
60%
80%
100%
120%
140%
160%
180%
200%
200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400
Relative Luminous Flux
Forward Current (mA)
Figure 1: Vero 18B Drive Current vs. Voltage
0
200
400
600
800
1000
1200
1400
1600
1800
2000
32 33 34 35 36 37 38 39
Forward Current (mA)
Forward Voltage (V)
Figure 2: Vero 18C Drive Current vs. Voltage
0
300
600
900
1200
1500
1800
2100
2400
2700
32 33 34 35 36 37 38 39
Forward Current (mA)
Forward Voltage (V)
24
Performance Curves
Figure 7: Typical DC Flux vs. Case Temperature
82%
85%
88%
91%
94%
97%
100%
103%
025 50 75 100 125
Relative Luminous Flux
Case Temperature (°C)
Warm White
Neutral White
Cool White
25°C Pulsed
Notes for Figures 7-9:
1. Characteristics shown for warm white based on 3000K and 80 CRI.
2. Characteristics shown for neutral white based on 4000K and 80 CRI.
3. Characteristics shown for cool white based on 5000K and 70 CRI.
4. For other color SKUs, the shift in color will vary. Please contact your Bridgelux Sales Representative for more information.
Figure 9: Typical DC ccx Shift vs. Case Temperature
Figure 8: Typical DC ccy Shift vs. Case Temperature
-0.012
-0.010
-0.008
-0.006
-0.004
-0.002
0.000
025 50 75 100 125
ccx Shift
Case Temperature (°C)
Warm White
Neutral White
Cool White
25°C Pulsed
-0.015
-0.012
-0.009
-0.006
-0.003
0.000
0.003
025 50 75 100 125
ccy Shift
Case Temperature (°C)
Warm White
Neutral White
Cool White
25°C Pulsed
25
Performance Curves
Figure 10: 1750K Color Shift vs. Case Temperature1
Figure 12: 2500K Color Shift vs. Case Temperature1
Note for Figures 10-15:
1. Measurements made under DC test conditions at the nominal drive current.
2. Typical color shift is shown with a tolerance of ±0.002.
3. Characteristics shown for Decor Series Showcase products, BXRC-30G400C-x-73
Figure 14: 2700K, 97 CRI Color Shift vs. Case Temperature1 Figure 15: 3000K, 97 CRI Color Shift vs. Case Temperature1
0.368
0.3685
0.369
0.3695
0.37
0.3705
0.5196 0.5198 0.52 0.5202 0.5204
0.5206
ccy
ccx
15°C
25°C
45°C
70°C
85°C
105°C
Pulsed Center Point
Tc = 25°C
0.4105
0.411
0.4115
0.412
0.4125
0.413
0.4135
0.414
0.4145
0.468 0.47 0.472 0.474 0.476 0.478
ccy
ccx
15°C
25°C
45°C
70°C
85°C
105°C
Pulsed
Center Point
Tc = 25°C
15°C
25°C
45°C
65°C
85°C
105°C
Pulsed Center
Point
Tc= 25°C
0.4030
0.4040
0.4050
0.4060
0.4070
0.4080
0.4090
0.4100
0.4110
0.457 0.4572 0.4574 0.4576 0.4578 0.458
ccy
ccx
15°C
25°C
45°C
70°C
85°C
105°C
Pulsed Center
Point
Tc= 25°C
0.3950
0.3970
0.3990
0.4010
0.4030
0.4050
0.4323 0.4328 0.4333 0.4338 0.4343 0.4348 0.4353
ccy
ccx
Figure 11: 2000K, 65 CRI Color Shift vs. Case Temperature
Figure 13: 3000K, 90 CRI Color Shift vs. Case Temperature1,3
Pulsed Center
Point Tc=25°C
15°C
25°C
45°C
65°C
85°C
105°C
0.395
0.396
0.397
0.398
0.399
0.4
0.401
0.402
0.403
0.444 0.4445 0.445 0.4455 0.446 0.4465 0.447
ccy
ccx
105°C
85°C
65°C
45°C
25°C
15°C
Pulsed Center
Point Tc=25°C
0.409
0.4091
0.4092
0.4093
0.4094
0.4095
0.4096
0.4097
0.4098
0.4099
0.41
0.4101
0.525 0.526 0.527 0.528 0.529 0.53 0.531 0.532
ccy
ccx
Figure 8: Typical DC ccy Shift vs. Case Temperature
26
Figure 16: 5600K Color Shift vs. Case Temperature1,3
Performance Curves
Figure 17: 3000K Class A Color Shift vs. Case Temperature1
Figure 19: 4000K Class A Color Shift vs. Case Temperature1 Figure 18: 3500K Class A Color Shift vs. Case Temperature1
Note for Figures 16-19:
1. Measurements made under DC test conditions at the nominal drive current.
2. Typical color shift is shown with a tolerance of ±0.002.
3. Color shift shown for product hot targeted at Tc=85°C
0.322
0.324
0.326
0.328
0.33
0.332
0.334
0.336
0.338
0.34
0.342
0.344
0.32 0.322 0.324 0.326 0.328 0.33
ccy
ccx
15°C
25°C
45°C
70°C
85°C
105°C
Pulsed Center
Point
Tc = 25°C
0.36
0.361
0.362
0.363
0.364
0.365
0.366
0.367
0.368
0.369
0.416 0.4165 0.417 0.4175 0.418 0.4185
ccy
ccx
Pulsed
Center Point
Tc=25°C
25°C
45°C
85°C
105°C
70°C
15°C
0.358
0.36
0.362
0.364
0.366
0.368
0.37
0.392 0.393 0.394 0.395 0.396 0.397
ccy
ccx
Pulsed
Center Point
Tc=25°C
15°C
45°C
85°C
105°C
70°C
25°C
0.3620
0.3640
0.3660
0.3680
0.3700
0.3720
0.3740
0.3760
0.373 0.374 0.375 0.376 0.377 0.378 0.379
ccy
ccx
Pulsed
Center Point
Tc=25°C
15°C
45°C
85°C
105°C
70°C
25°C
100% 90% 80% 70% 60% 50% 40% 30% 20% 10% 0% Relative Intensity (96) -9D' -80' -70' -60' -50' 40' -3|)' -20' -10' 0' 10' 20' 30' 40' 50' 60‘ 70' 80' 90' Angular Dlsplloemem (') 45‘ 0' 15' 30' ‘5- 75'
27
Typical Radiation Pattern
Figure 20: Typical Spatial Radiation Pattern
Figure 21: Typical Polar Radiation Pattern
Note for Figure 20:
1. Typical viewing angle is 120.
2. The viewing angle is defined as the off axis angle from the centerline where intensity is ½ of the peak value.
28
Typical Color Spectrum
Figure 22: Typical Color Spectrum
Note for Figure 22:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
2. Color spectra shown is 3000K and 80 CRI.
3. Color spectra shown is 4000K and 80 CRI.
4. Color spectra shown is 5000K and 70 CRI.
4. Color spectra shown is 6500K and 70 CRI.
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
110%
400 450 500 550 600 650 700 750 800
Relative Spectral Power Distribution
Wavelength (nm)
3000K
4000K
5000K
6500K
Figure 23: Typical Color Spectrum for Vero 18 with Décor Series
Note for Figure 23:
1. Color spectra measured at nominal current for Tj = Tc = 25°C.
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
1
400 450 500 550 600 650 700 750 800
Relative Spectral Power Distribution
Wavelength (nm)
17E
20B
25E
27H
30G (Décor Series Showcase)
30H
56G
56H
29
Mechanical Dimensions
Figure 24: Drawing for Vero 18 LED Array
Notes for Figure 24:
1. Drawings are not to scale.
2. Drawing dimensions are in millimeters.
3. Unless otherwise specified, tolerances are ±0.1mm.
4. Mounting holes (2X) are for M2.5 screws.
5. Bridgelux recommends two tapped holes for mounting screws with 31.4 ± 0.10mm center-to-center spacing.
6. Screws with flat shoulders (pan, dome, button, round, truss, mushroom) provide optimal torque control. Do NOT use flat,
countersink, or raised head screws.
7. Solder pads and connector port are labeled “+” and “-“ to denote positive and negative, respectively.
8. It is not necessary to provide electrical connections to both the solder pads and the connector port. Either set may be used
depending on application specific design requirements.
9. Refer to Application Notes AN30 and AN31 for product handling, mounting and heat sink recommendations.
10. The optical center of the LED Array is nominally defined by the mechanical center of the array to a tolerance of ± 0.2mm.
11. Bridgelux maintains a flatness of 0.10mm across the mounting surface of the array.
/‘ ”/5? 9/0” LL: 0 ¢/<9w wv="" pauuxuuuuu="">
30
Figure 25: Warm and Neutral White Test Bins in xy Color Space
Figure 26: Cool White Test Bins in xy Color Space
Color Binning Information
Bin Code 1750K 2000K 2500K 2700K 3000K13500K14000K1
ANSI Bin
(for reference only) ---(2580K - 2870K) (2870K - 3220K) (3220K - 3710K) (3710K - 4260K)
73 (3 SDCM) - - - (2651K - 2794K) (2968K - 3136K) (3369K - 3586K) (3851K - 4130K)
72 (2 SDCM) - - - (2674K - 2769K) (2995K - 3107K) (3404K - 3548K) (3895K - 4081K)
Center Point (x,y) (0.5167, 0.336) (0.5280, 0.4100) (0.4765, 0.4137) (0.4578, 0.4101) (0.4338, 0.403)
(0.4465, 0.4024)2(0.4073, 0.3917) (0.3818, 0.3797)
Table 8: Warm and Neutral White xy Bin Coordinates and Associated Typical CCT
Bin Code 5000K 5600K 5700K 6500K
ANSI Bin (for reference only) (4745K - 5311K) (5310K - 6020K) (5312K - 6022K) (6022K - 7042K)
74 (4 SDCM) (4801K - 5282K) (5475K - 5830K) (5481K - 5829K) (6270K - 6765K)
73 (3 SDCM) (4835K - 5215K) (5490K - 5820K) (5490K - 5820K) (6250K - 6745K)
Center Point (x,y) (0.3447, 0.3553) (0.3293, 0.3423) (0.3287, 0.3417) (0.3123, 0.3282)
Table 9: Cool White xy Bin Coordinates and Associated Typical CCT (product is hot targeted to Tc = 85°C)
Note: Pulsed Test Conditions, Tc = 25°C
Note: Pulsed Test Conditions, Tc = 25°C Note: Pulsed Test Conditions, Tc = 25°C
Note for Table 9:
1. Select configurations with a CCT of 5600K are available with center point targets at Tc = 85°C or Tc = 25°C.
Note for Table 8:
1. Color Binning information excludes Decor Series Class A products. Please contact your Bridgelux Sales Representative for more information.
2. Center Point for Decor Series Showcase.
0.34
0.36
0.38
0.4
0.42
0.44
0.36 0.39 0.42 0.45 0.48 0.51 0.54
Y
X
3 SDCM
4 SDCM
3500K
2500K
4SDCM
1750K
4SDCM
2000K
3SDCM
2700K
3000K
4000K
0.3
0.31
0.32
0.33
0.34
0.35
0.36
0.37
0.38
0.39
0.3 0.31 0.32 0.33 0.34 0.35 0.36
Y
X
4 SDCM
3 SDCM
6500K
5700K
5000K
(541 E
31
Packaging and Labeling
Figure 27: Drawing for Vero 18 Packaging Tray
Notes for Figure 27:
1. Dimensions are in millimeters.
2. Drawings are not to scale.
( m IIIIIHIIIIII \ u ,srazzm \: III‘IIHIIHI , (1 5 ; MI ‘ in (u IIIHII @ ,4, Cc .u.‘ >0“. .._.._. ,1 www.mmm , m g I I‘lll Q .5. c 5“,. "mm.”
32
Packaging and Labeling
Figure 28: Vero Series Packaging and Labeling
Notes for Figure 28:
1. Each tray holds 100 COBs.
2. Each tray is vacuum sealed in an anti-static bag and placed in its own box.
3. Each tray, bag and box is to be labeled as shown above.
Figure 29: Gen. 7 Product Labeling
Bridgelux COB arrays have laser markings on the back side of the substrate to help with product identification. In
addition to the product identification markings, Bridgelux COB arrays also contain markings for internal Bridgelux
manufacturing use only. The image below shows which markings are for customer use and which ones are for
Bridgelux internal use only. The Bridgelux internal manufacturing markings are subject to change without notice,
however these will not impact the form, function or performance of the COB array.
Customer Use- 2D Barcode
Scannable barcode provides
product part number and other
Bridgelux internal production
information.
Customer Use- Product part number 30E4000C 73 2F Customer Use- Vf Bin Code
included to enable greater
luminaire design flexibility.
Refer to AN92 for bin code
definitions.
33
Design Resources
Disclaimers
Precautions
Application Notes
Bridgelux has developed a comprehensive set of
application notes and design resources to assist
customers in successfully designing with the Vero
product family of LED array products. For all available
application notes visit www.bridgelux.com.
Optical Source Models
Optical source models and ray set files are available
for all Bridgelux products. For a list of available formats,
visit www.bridgelux.com.
MINOR PRODUCT CHANGE POLICY
The rigorous qualification testing on products offered
by Bridgelux provides performance assurance. Slight
cosmetic changes that do not affect form, fit, or function
may occur as Bridgelux continues product optimization.
CAUTION: CHEMICAL EXPOSURE HAZARD
Exposure to some chemicals commonly used in
luminaire manufacturing and assembly can cause
damage to the LED array. Please consult Bridgelux
Application Note AN31 for additional information.
CAUTION: RISK OF BURN
Do not touch the Vero LED array during operation. Allow
the array to cool for a sufficient period of time before
handling. The Vero LED array may reach elevated
temperatures such that could burn skin when touched.
3D CAD Models
Three dimensional CAD models depicting the product
outline of all Bridgelux Vero LED arrays are available
in both IGS and STEP formats. Please contact your
Bridgelux sales representative for assistance.
LM80
LM80 testing has been completed and the LM80 report
is now available. Please contact your Bridgelux sales rep-
resentative for LM-80 report.
CAUTION
CONTACT WITH LIGHT EMITTING SURFACE (LES)
Avoid any contact with the LES. Do not touch the
LES of the LED array or apply stress to the LES
(yellow phosphor resin area). Contact may cause
damage to the LED array.
Optics and reflectors must not be mounted in contact
with the LES (yellow phosphor resin area). Optical
devices may be mounted on the top surface of the
plastic housing of the Vero LED array. Use the
mechanical features of the LED array housing, edges
and/or mounting holes to locate and secure optical
devices as needed.
STANDARD TEST CONDITIONS
Unless otherwise stated, array testing is performed
at the nominal drive current.
brldgeltpxo
34
About Bridgelux: Bridging Light and Life
© 2016-2018 Bridgelux, Inc. All rights reserved 2018. Product specifications are subject to change without notice. Bridgelux, the Bridgelux stylized logo design, Vero,
V Series and V Series HD are registered trademarks, and Decor Series is a trademark of Bridgelux, Inc. All other trademarks are the property of their respective owners.
Bridgelux Gen 7 Vero 18 Array Series Product Data Sheet DS92 Rev. N (10/2018)
46430 Fremont Boulevard
Fremont, CA 94538 U.S.A.
Tel (925) 583-8400
www.bridgelux.com
At Bridgelux, we help companies, industries and people experience the power and possibility
of light. Since 2002, we’ve designed LED solutions that are high performing, energy efficient,
cost effective and easy to integrate. Our focus is on light’s impact on human behavior, deliver-
ing products that create better environments, experiences and returns—both experiential and
financial. And our patented technology drives new platforms for commercial and industrial
luminaires.
For more information about the company, please visit
bridgelux.com
twitter.com/Bridgelux
facebook.com/Bridgelux
youtube.com/user/Bridgelux
linkedin.com/company/bridgelux-inc-_2
WeChat ID: BridgeluxInChina