6
Product Selection Guide
Table 3: Selection Guide, Stabilized DC Performance (Tc = 85°C) 4,5
Part Number Nominal CCT1
(K) CRI2
Nominal Drive
Current3
(mA)
Typical DC
Flux4,5
Tc = 85ºC
(lm)
Minimum DC
Flux6
Tc = 85ºC
(lm)
Typical Vf
(V)
Typical
Power
(W)
Typical
Efficacy
(lm/W)
BXRE-17E2000-C-74 1750 80 630 1745 1571 33.9 21.4 82
BXRE-20B2001-B-73 2000 65 450 2102 1892 33.9 15.3 138
BXRE-20B2001-C-73 2000 65 630 2943 2648 33.9 21.4 138
BXRE-25E2000-C-74 2500 80 630 2821 2539 33.9 21.4 132
BXRE-27E2000-B-7x 2700 80 450 2160 1944 33.9 15.3 142
BXRE-27E2000-C-7x 2700 80 630 3024 2721 33.9 21.4 142
BXRE-27G20H0-B-7x 2700 90 450 1872 1685 33.9 15.3 123
BXRE-27G20H0-C-7x 2700 90 630 2621 2358 33.9 21.4 123
BXRE-27G2000-B-7x 2700 90 450 1797 1618 33.9 15.3 118
BXRE-27G2000-C-7x 2700 90 630 2516 2265 33.9 21.4 118
BXRE-27H2000-B-7x 2700 97 450 1566 1409 33.9 15.3 103
BXRE-30C2001-B-74 3000 70 450 2477 2229 33.9 15.3 162
BXRE-30C2001-C-74 3000 70 630 3468 3121 33.9 21.4 162
BXRE-30E2000-B-7x 3000 80 450 2247 2022 33.9 15.3 147
BXRE-30E2000-C-7x 3000 80 630 3146 2831 33.9 21.4 147
BXRE-30G20H0-B-7x 3000 90 450 1956 1761 33.9 15.3 128
BXRE-30G20H0-C-7x 3000 90 630 2739 2465 33.9 21.4 128
BXRE-30G2000-B-7x 3000 90 450 1870 1683 33.9 15.3 123
BXRE-30G2000-C-7x 3000 90 630 2618 2356 33.9 21.4 123
BXRE-30G200C-B-73 3000 90 450 1740 1566 33.9 15.3 114
BXRE-30G200C-C-73 3000 90 630 2435 2192 33.9 21.4 114
BXRE-30A2001-B-738,9 3000 93 450 1689 1520 33.9 15.3 111
BXRE-30A2001-C-738,9 3000 93 630 2364 2128 33.9 21.4 111
BXRE-30H2000-B-7x 3000 97 450 1667 1500 33.9 15.3 109
BXRE-35E2000-B-7x 3500 80 450 2319 2087 33.9 15.3 152
BXRE-35E2000-C-7x 3500 80 630 3247 2922 33.9 21.4 152
BXRE-35G2000-B-7x 3500 90 450 1928 1735 33.9 15.3 126
BXRE-35G2000-C-7x 3500 90 630 2699 2429 33.9 21.4 126
BXRE-35A2001-B-738,9 3500 93 450 1816 1634 33.9 15.3 119
BXRE-35A2001-C-738,9 3500 93 630 2542 2288 33.9 21.4 119
BXRE-40C2001-B-74 4000 70 450 2519 2267 33.9 15.3 165
BXRE-40C2001-C-74 4000 70 630 3527 3174 33.9 21.4 165
BXRE-40E2000-B-7x 4000 80 450 2334 2100 33.9 15.3 153
Notes for Table 3:
1. Nominal CCT as defined by ANSI C78.377-2011. Products with a CCT of 5000K-6500K are hot targeted to Tc = 85°C.
2. All CRI values are measured at Tj = Tc = 25°C. CRI values are typical for Decor Series Ultra, Décor Series Street and Landmark and Decor Series Class A
products. CRI values are minimums for all other products. Minimum R9 value for 80 CRI products is 0, the minimum R9 values for 90 CRI products is 50, the
minimum R9 values for 97 CRI products is 93. Bridgelux maintains a ± 3 tolerance on R9 values.
3. Drive current is referred to as nominal drive current.
4. Typical stabilized DC performance values are provided as reference only and are not a guarantee of performance.
5. Typical performance is estimated based on operation under DC (direct current) with LED array mounted onto a heat sink with thermal interface
material and the case temperature maintained at 85°C. Based on Bridgelux test setup, values may vary depending on the thermal design of the
luminaire and/or the exposed environment to which the product is subjected.
6. Minimum flux values at elevated temperatures are provided for reference only and are not guaranteed by 100% production testing. Based on Bridgelux test
setup, values may vary depending on the thermal design of the luminaire and/or the exposed environment to which the product is subjected.
7. Nominal CCT is defined by the Lighting Research Center’s Class A definition. The center of the Class A color bin is on the corresponding isothermal line.
8. GAI value is 80. To help ensure optimal fixture level performance, GAI is measured at the fixture level, on axis, at a case temperature of 70°C. GAI may vary
depending on fixture design and performance.