PGFM Series Datasheet by Sensata-Airpax

FEATURES
• Sensingmoduleoperatesat120VACor240VAC,singlephase
•Unitoperatingtemperatureis-35°Cto+66°C
•Accommodatesupto2wires,10AWG,twistingofthewires
 isrequired
• Powerandfaultstatusindicators
•Providesidentificationofagroundfaultvs.shortcircuittrip
•ChemicalandUVresistantenclosure
•Triplevelofsensingdevice5mA±1mAClassAUL943
INTRODUCTION
TheLineGard™PGFMGFCISensingModuleisagroundfaultorequipmentleakagesensingdevice
designedandmanufacturedbyNorthShoreSafety,aleaderininnovativesafetyproducts.ThePGFM
operatesintandemwithanapprovedAirpaxLELSeries,UL489listedcircuitbreaker,withshunttrip
andauxiliaryswitch.
Thecombined assembly isrecognizedasaClassAUL943rateddevice.Thesensingmoduleis
availableinmodelstooperateatsupplyvoltagesof120VACor240VACandcanmonitorsingleand
splitphasecircuits.
ThesedevicesmeettherequirementsofOSHA29CFR1926.404(b)(1)(ii)andOSHA29CFR1926.405(a)
(2)(ii)(G).
Airpax™LELseries
PGFM Series - Introduction http://airpax.sensata.com
211
PGFM Series
GFCI Ground Fault Protection Sensing Module
Type E-11GFP-UL943CategoryFTTJ2whenusedintandemwithAirpaxLELseriesUL489
listedcircuitbreakerwithshunttrip
Operating Voltage 120VACor120/240VAC
Interrupting Voltage RatingofUL489listedcircuitbreaker
Sensing Coil Voltage Limit 600VACmaximum
Phase Interrupt Single(120VAC3wire)andSplit(120/240VAC4wire)
Interrupting Current RatingofUL489listedcircuitbreaker
Trip Time of Combined Assembly 100mSorless(60mSnominal)
Trip Level 5mA+/-1mA
Frequency 50/60Hz
Operating Temperature -35°Cto+66°C
Reset Type Automaticonpowerup
Note:1.Manualconfigurationshouldbespecifiedifautomaticstart-upafterpowerrestorationofcircuitpowercreatesanunsafecondition.
2.AsperUL943requirements,portabledevicesmayrequirebreakingofneutralduringgroundfaultdetection.Pleasecontactthefactory.
3.PleasecontactAirpaxforoptionalELCI,UL1053compliantdevices.
SPECIFICATIONS
—7PGFM- 1 10- Operating Voltage :/guratiox—1 ResetType”
DIMENSIONS CIRCUIT SCHEMATIC (EXAMPLES)
2 Operating Voltage
1 120VAC
2 240VAC
3 Configuration
1 Shunt w/ Aux. Switch
4 Reset Type**
0 Manual
1 Automatic
5 Assembly Options
B Matching circuit breaker
(see below)
PGFM - 1 1 0 - B - A1
Product Type
16 Installation Kit*
A1 Test instruction label
Circuit breaker jumper wire
Mounting gasket
2 mounting screws (M3)
Todetermineamatchingcircuitbreakerforuseintandemwith
theLineGard™SensingModule,pleasecontactusdirectly
oryourlocalSensataRepresentativeforassistancewiththe
appropriateidentifyingpartnumber.
Orange
shunt
jumper
System Neutral (N)
1.30
[33.0]
2.18
[55.4]
2.52
[64.0]
3.41
[86.6]
2.62
[66.5]
3.67
[93.2]
3.28
[83.3]
M3 inserts
Recommended torque 4 - 5
inch pounds
Orange
shunt
jumper
Orange
shunt
jumper
LOAD
LOAD
LOAD
LINE
LINE LINE
H
N
L1
L2
N
L1
L2
GRND GRND
GRND
NO
C
NO
NO
C
C
Circuit
Breaker
120VAC GFCI
Sensing Module
240VAC GFCI
Sensing Module
120VAC GFCI
Sensing Module
Part #
Auto PGFM-111B
Man. PGFM-110B
Part #
Auto PGFM-111B
Man. PGFM-110B
Part #
Auto PGFM-211B
Man. PGFM-210B
White Black White Black
Black
Red
Yellow (Shunt)Yellow (Shunt)
Yellow (Shunt)
System Neutral (N)
Single Phase 120VAC (Hot, Neutral, GRND) Split Phase 120/240VAC (L1, L2, Neutral, GRND)
Single Phase 240VAC (L1, L2, GRND)
Circuit
Breaker
Circuit
Breaker
Notice:Currentcarryingwiresmustbe
twistedtogetherastheypassthrough
thesensingmodule
PGFM Series - Part Number Scheme
GFCI&ELCI
212
Sensata Technologies
©2013 Sensata Technologies, Inc. All rights reserved worldwide. The following data sheet is an excerpt from our Airpax™ Power
Protection Catalog, Literature # 2455005000, printed in the USA, May 9th, 2013.
Important Notice: Sensata Technologies reserves the right to make changes to, or to discontinue, any product or service identified in
this publication without notice. Before placing orders, users should obtain the latest version of the relevant information to verify that
the information being relied upon is current.
Sensata Technologies assumes no responsibility for customers’ product designs or applications. Users must determine the suitability
of the Sensata device described in this publication for their application, including the level of reliability required. Many factors beyond
Sensata’s control can affect the use and performance of a Sensata product in a particular application, including the conditions under
which the product is used and the time and environmental conditions in which the product is expected to perform. As these factors
are uniquely within the user’s knowledge and control, it is essential that the user evaluate the Sensata product to determine whether it
is fit for a particular purpose and suitable for the user’s application.
Sensata Technologies products are sold subject to Sensata’s Terms and Conditions of Sale which can be found at:
www.sensata.com/terms.htm
http://airpax.sensata.com/
Sensata Technologies Inc.
529 Pleasant Street
Attleboro, MA 02703, USA
Phone: +1 508-236-3287
FEATURES
• Protectionrangeandoperatingvoltage:
0-50Amps,120VAC,120/240VAC
•Unitoperatingtemperatureis-35°Cto+66°C
•Accommodatesupto3wires,6AWG,withnotwisting
 ofthewiresrequired
• Powerandfaultstatusindicators
•Providesidentificationofagroundfaultvs.shortcircuittrip
•ChemicalandUVresistantenclosure
•Triplevelofsensingdevice<30mA(27mAnominal)
attriptimeof<100mS(60mSnominal)perE-11
INTRODUCTION
TheLineGard™PGFMproductfamilyprovidesELCI(equipmentleakage)groundfaultsensingandis
designedandmanufacturedbyNorthShoreSafety,aleaderininnovativesafetyproducts.ThePGFM
seriesoperatesintandemwithanAirpax™LELseries,UL489listedcircuitbreaker,withshunttripand
auxiliaryswitchmanufacturedbySensataTechnologies.ThePGFMcanbepairedwithanAirpax™
IDLNKbreakerforapplicationsrequiringignitionprotection.
Thecombined assembly ofthePGFMandanAirpax™breakermeetstherequirementsofABYCE-11
forgroundfaultprotectionandmainshorepowercircuitprotection.ThePGFMconstantlymonitorsthe
currentbalanceoftheconductors(wires/cables)supplyingpowertotheload.Whenagroundfaultof
27mAnominal(30mAmax)occurs,thePGFMusestheLELsshunttripcoiltosignalthebreakertotrip. Airpax™LELseries
PGFM Series - ELCI / Marine Introduction http://airpax.sensata.com
213
PGFM Series (ELCI, Marine)
ELCI Marine Ground Fault Protection Sensing Module
Type E-11GFP-UL943CategoryFTTJ2whenusedintandemwithAirpaxLELseries(UL489
listedcircuitbreakerwithshunttrip)
Operating Voltage 120VACor120/240VAC,50/60Hz
Interrupting Voltage RatingofUL489listedcircuitbreaker
Sensing Coil Voltage Limit 600VACmaximum
Phase Interrupt Single(120VAC3wire),Split(120/240VAC4wire),240VAC3-wire(L1,L2,N)
Interrupting Current 120VAC,50A,5kAIC
120/240VAC,50A,5kAIC
Trip Time of Combined Assembly 100mSorless(60mSnominal)
Trip Level 27mA+/-2mA
Operating Temperature -35°Cto+66°C
Reset Type Automaticonpowerup
ABYC E-11 Acceptability TheLineGard™PGFMELCImoduleusedintandemwiththeAirpax™circuitbreakermeets
therequirementsoftheABYC(AmericanBoatandYachtCouncil)E-11standardcovering
ACandDCsystemsonboats
SPECIFICATIONS
AIRPAX™ LEL & IDLNK SERIES CIRCUIT BREAKER RATINGS (PER UL489)
Voltage Current Frequency Short Circuit Poles
125VAC 0.05to50amps 50/60Hz 5,000amps 1to3
120/240VAC .05to50amps 50/60Hz 5,000amps 2to3
AIRPAX™ LEL & IDLNK SERIES CIRCUIT BREAKER SPECIFICATIONS
Moisture Resistance MIL-STD-202,Method106
Salt Spray (Corrosion) MIL-STD-202,Method101
Shock MIL-STD-202,Method213,TestConditionIwith100%ratedcurrentapplied
Vibration MIL-STD-202,Method204,TestConditionAwith100%ratedcurrentapplied
LEL Agency Approvals UL489Listed,CSACertified,VDEApproved,CCCApproved,CECompliant
IDLNK Agency Approvals UL1077Recognized,C22.2No.235complainttoUL1500orSAEJ1171ignitionprotection
LINEGARD™ PGFM SERIES ELCI SPECIFICATIONS
Salt Fog (Corrosion) ASTMB117
Shock 33CFR183.534-modifiedtosupply5,000shocks@25G,
insteadofteststandardof1,000shocks
Vibration MIL-STD-810(randomvibe4GRMS),IEC6945(sinesweep5to100Hzforlowfrequency)
Ignition Protection SAEJ1171(UL1500)
PGFM Series - Circuit Breakers & ABYC E-11
GFCI&ELCI
214
chlmolnllns
PGFM Series - ELCI / Marine Wiring Diagrams http://airpax.sensata.com
215
L1 (black) to master pole* of breaker
L2 (red) to breaker line side L2
L1 (black) to master pole* of breaker
L2 (red) to circuit breaker line input
SHUNT (yellow) to breaker auxiliary switch (NO terminal)
L1 (black) from power supply (source)
L2 (red) from power supply (source)
L1 (black) to master pole* of breaker
NEUTRAL (white) to breaker line side NEUTRAL
L1 (black) to master pole* of breaker
L2 (red) to circuit breaker line input
NEUTRAL (white) to circuit breaker line input
SHUNT (yellow) to breaker auxiliary switch (NO terminal)
L1 (black) from power supply (source)
L2 (red) from power supply (source)
NEUTRAL (white) from power supply (source)
NEUTRAL (white) to breaker line side NEUTRAL
HOT (black) to master pole* of breaker
NEUTRAL (white) to breaker line input
HOT (black) to master pole* of breaker
SHUNT (yellow) to breaker auxiliary switch (NO terminal)
NEUTRAL (white) from power supply (source)
HOT (black) from power supply (source)
*Master pole is the pole that houses the toggle handle on the breaker
WIRING DIAGRAM (240 VAC APPLICATION)
WIRING DIAGRAM (120VAC APPLICATION)
L1 (black) to master pole* of breaker
L2 (red) to breaker line side L2
L1 (black) to master pole* of breaker
L2 (red) to circuit breaker line input
SHUNT (yellow) to breaker auxiliary switch (NO terminal)
L1 (black) from power supply (source)
L2 (red) from power supply (source)
L1 (black) to master pole* of breaker
NEUTRAL (white) to breaker line side NEUTRAL
L1 (black) to master pole* of breaker
L2 (red) to circuit breaker line input
NEUTRAL (white) to circuit breaker line input
SHUNT (yellow) to breaker auxiliary switch (NO terminal)
L1 (black) from power supply (source)
L2 (red) from power supply (source)
NEUTRAL (white) from power supply (source)
NEUTRAL (white) to breaker line side NEUTRAL
HOT (black) to master pole* of breaker
NEUTRAL (white) to breaker line input
HOT (black) to master pole* of breaker
SHUNT (yellow) to breaker auxiliary switch (NO terminal)
NEUTRAL (white) from power supply (source)
HOT (black) from power supply (source)
*Master pole is the pole that houses the toggle handle on the breaker
L1 (black) to master pole* of breaker
L2 (red) to breaker line side L2
L1 (black) to master pole* of breaker
L2 (red) to circuit breaker line input
SHUNT (yellow) to breaker auxiliary switch (NO terminal)
L1 (black) from power supply (source)
L2 (red) from power supply (source)
L1 (black) to master pole* of breaker
NEUTRAL (white) to breaker line side NEUTRAL
L1 (black) to master pole* of breaker
L2 (red) to circuit breaker line input
NEUTRAL (white) to circuit breaker line input
SHUNT (yellow) to breaker auxiliary switch (NO terminal)
L1 (black) from power supply (source)
L2 (red) from power supply (source)
NEUTRAL (white) from power supply (source)
NEUTRAL (white) to breaker line side NEUTRAL
HOT (black) to master pole* of breaker
NEUTRAL (white) to breaker line input
HOT (black) to master pole* of breaker
SHUNT (yellow) to breaker auxiliary switch (NO terminal)
NEUTRAL (white) from power supply (source)
HOT (black) from power supply (source)
*Master pole is the pole that houses the toggle handle on the breaker
WIRING DIAGRAM (120/240 VAC APPLICATION)
PGFM Series - ELCI / Marine Installation & Testing
GFCI&ELCI
216
1.Readandfollowallinstructions
2.Identifyallthefeaturesandwires(seedrawings)
3.Identifylinewiresandloadwires
4.Verifythattheratingsonthedevice,includingthecircuit
 breaker,matchyourfieldlineratings
5.Stripwiresto5/8”,orasrecommendedforyourconnections
 (modulemayincludefieldterminations)
6.Choosetherightwiringapplication(120VACor120/240VAC
 splitphase)andconnectwiresaccordingtodiagrams
7.Placesuppliedtestinstructionlabelincloseproximitytothe
 groundfaultsensingmodulemountinglocation.
NOTE:Thegroundwireshouldbeconnectedexternally.The
Groundwiredoesnotenterorexitthegroundfaultsensing
module.AlthoughthePGFMdoesnotmonitorgroundleadsor
requiregroundtooperate,groundconnectionisrecommended
andshouldbemadeatjunctionbox.
Inthenormaloperatingstate,thePGFMgreenLEDis“ON”and
circuitbreakerisinthe“ON”position.
1.Press“TEST”button:GreenLEDshouldgo“OFF”andredLED
 shouldcome“ON”andcircuitbreakershouldtriggerto“OFF”
 position
2.IfsensingdeviceredLEDdoesnotilluminateorbreakerdoes
 nottriporchangestate,DONOTUSEandconsultan
 electricianforassistance
3.Press“RESET”button:RedLEDshouldturn“OFF”andgreen
 LEDshouldturn“ON”
4.Manuallyreset(switch)thecircuitbreakertothe“ON”
 positiontorestorecircuitpower
WARNING:Ifthetestfails,donotusethisELCI.Consulta
qualifiedelectricianforrepairorreplacement.
INSTALLATION INSTRUCTIONS TESTING AND TROUBLESHOOTING
WIRING DIAGRAM (ORANGE JUMPER WIRE FOR CIRCUIT BREAKER)
C
NO
LINE
LOAD
DANGER!
Hazardofelectricalshock,burnorexplosion.
Disconnectpoweratmainpowerfeedbefore
youstartinstallation.Failuretodosomaycause
severeshock,personalinjury,ordeath.
!
DIMENSIONAL DRAWINGS (PGFM MARINE)
1.850 [46.99]
0.007 [0.18]
2.353 [59.77]
1.320 [33.53]
0.657 [16.68]
2.655 [67.44] DIAMETER
2.788 [70.82] DIAMETER
M3.0 x .5 THREADED BRASS
INSERTS FOR MOUNTING (2) PLACES
.710 [18.03] DIAMETER
(LARGE ENOUGH FOR THREE 6GA. WIRES)
16 GA. WIRE 105 DEGREES C
UL STYLE 1015 / 1230 600V
CSA TEW 10 IN LONG +/- 1 IN
COLOR WIRE 1: WHITE 120V, RED 240V
COLOR WIRE 2: BLACK 120V, BLACK 240V
COLOR WIRE 3: YELLOW 120V, YELLOW 240V
WIRE 3 WITH QUICK DISCONNECT MOLEX PN
19006-0015 OR EQUIVALENT
M ‘ H331 a :fl: m .1 - m % V E SE \ ,
PGFM Series - UL 489 Circuit Breakers http://airpax.sensata.com
217
DIMENSIONAL DRAWINGS (EXAMPLE OF LEL, TYPICAL 2-POLE CONFIGURATION)
[7.14]
.281
[49.28]
1.940
[16.46]
.648
[26.80]
1.055
[5.59]
.220
[52.32]
2.060
[61.93]
2.438 MAX.
[10.21]
.402
[36.53]
1.438
[63.25]
2.490
[38.48]
1.515 MAX.
4X M3 ISO THD.
.140 [3.56] DEEP
[29.13]
1.147
[18.31]
.721
[65.02]
2.560
[3.56]
.140
[47.22]
1.859
[3.61]
.142
[17.53]
.690
32°
32°
ON
OFF
[6.35]
.250 [9.03]
.356
[0.76]
.030
20
[24.25]
.955
C
NO NC
[6.35]
.250
[4.75]
.187
1REC5
C & NO
4X M5 SCREW
[19.05]
.750
PanelMountingDetail
Tolerance±.005[.13]unlessnoted.
COMPATIBLE AIRPAX™ CIRCUIT BREAKERS - UL 489 LISTED; VDE PER EN 60934 (NON-IGNITION PROTECTED)
Amps Poles Part Number Voltage Trip Coil Short Circuit Delay Curve
30 2 LEL12-1REC5-37583-30-G1-V 120V 120V 5000A
30 2 LEL12-1REC5-37583-30-G2-V 240V 240V 5000A
30 3 LEL121-1REC5-37275-30-G1-V 120/240V 120V 5000A
50 2 LELK12-1REC5-37583-50-G1-V 120V 120V 5000A
50 2 LELK12-1REC5-37583-50-G2-V 240V 240V 5000A
50 3 LELK121-1REC5-37275-50-G1-V 120/240V 120V 5000A
800
700
600
500
400
300
200
150
125
100
0
TIME IN SECONDS
10
1
.1
1000
100
.01
10000
.001
PERCENT OF RATED CURRENT
1000
900
DELAY 61
MAY TRIP
800
700
600
500
400
300
200
150
125
100
0
TIME IN SECONDS
10
1
.1
1000
100
.01
10000
.001
PERCENT OF RATED CURRENT
1000
900
DELAY 62DELAY 62DELAY 62
MAY TRIP
800
700
600
500
400
300
200
150
125
100
0
TIME IN SECONDS
10
1
.1
1000
100
.01
10000
.001
PERCENT OF RATED CURRENT
1000
900
DELAY 63
MAY TRIP
800
700
600
500
400
300
200
150
125
100
0
TIME IN SECONDS
10
1
.1
1000
100
.01
10000
.001
PERCENT OF RATED CURRENT
1000
900
DELAY 69
MAY TRIP
PGFM Series - UL 1077 Circuit Breakers
GFCI&ELCI
218
DIMENSIONAL DRAWINGS (EXAMPLE OF IDLNK, TYPICAL 2-POLE CONFIGURATION)
6-32 Mtg Screw
for High Shock
Mtg
[51.82]
2.040
[3.61]
.142
[24.25]
.955
[19.05]
.750
[34.92]
1.375
[16.66]
.656
[63.25]
2.490
.0325 ± 0.0025 [0.83 ± 0.064] DEEP
.0625 ± 0.0025 [1.59 ± 0.064] WIDE
[15.88]
.625
[3.30]
.130
[19.05]
.750
[13.08]
.515
[16.66]
.656
1/2-32 Hex Nut
OFF 13° ± 3°
ON 13° ± 3°
Lockwasher
Rubber “O” Ring
[38.48]
1.515
KEYWAY
MAX
PanelMountingDetail
Tolerance±.005[.13]unlessnoted.
COMPATIBLE AIRPAX™ CIRCUIT BREAKERS - UL 1077 RECOGNIZED; IGNITION PROTECTED PER SAE J1171 (UL 1500)
Amps Poles Part Number Voltage Trip Coil Short Circuit Delay Curve
30 2 IDLNK21-1REC5-38140-30-G1 120V 120V 5000A
30 2 IDLNK21-1REC5-38140-30-G2 240V 240V 5000A
30 3 IDLNK121-1REC5-39945-30-G1 120/240V 120V 5000A
50 2 IDLNK21-1REC5-38140-50-G1 120V 120V 5000A
50 2 IDLNK21-1REC5-38140-50-G2 240V 240V 5000A
50 3 IDLNK121-1REC5-39945-50-G1 120/240V 120V 5000A
800
700
600
500
400
300
200
150
125
100
0
TIME IN SECONDS
10
1
.1
1000
100
.01
10000
.001
PERCENT OF RATED CURRENT
1000
900
DELAY 61
MAY TRIP
800
700
600
500
400
300
200
150
125
100
0
TIME IN SECONDS
10
1
.1
1000
100
.01
10000
.001
PERCENT OF RATED CURRENT
1000
900
DELAY 62DELAY 62DELAY 62
MAY TRIP
800
700
600
500
400
300
200
150
125
100
0
TIME IN SECONDS
10
1
.1
1000
100
.01
10000
.001
PERCENT OF RATED CURRENT
1000
900
DELAY 63
MAY TRIP
800
700
600
500
400
300
200
150
125
100
0
TIME IN SECONDS
10
1
.1
1000
100
.01
10000
.001
PERCENT OF RATED CURRENT
1000
900
DELAY 69
MAY TRIP
—7P_GFM- 110 B-A1- 188— Operating Voltage Conflgurmion A T;—
PGFM Series - Decision Tables http://airpax.sensata.com
219
2 Operating Voltage
1 120VAC
2 240VAC
3 Configuration
1 Shunt w/ Aux. Switch
4 Reset Type
1 Automatic
5 Assembly Options
B Matching circuit breaker
(see below)
PGFM - 1 1 0 - B - A1 - 188
Product Type
1
6 Installation Kit
A1 Test instruction label
Circuit breaker jumper wire
Mounting gasket
2 mounting screws (M3)
7 Physical Shape
-188 Round Configuration
DECISION TABLES (PGFM Series)
Sensata Technologies
©2013 Sensata Technologies, Inc. All rights reserved worldwide. The following data sheet is an excerpt from our Airpax™ Power
Protection Catalog, Literature # 2455005000, printed in the USA, May 9th, 2013.
Important Notice: Sensata Technologies reserves the right to make changes to, or to discontinue, any product or service identified in
this publication without notice. Before placing orders, users should obtain the latest version of the relevant information to verify that
the information being relied upon is current.
Sensata Technologies assumes no responsibility for customers’ product designs or applications. Users must determine the suitability
of the Sensata device described in this publication for their application, including the level of reliability required. Many factors beyond
Sensata’s control can affect the use and performance of a Sensata product in a particular application, including the conditions under
which the product is used and the time and environmental conditions in which the product is expected to perform. As these factors
are uniquely within the user’s knowledge and control, it is essential that the user evaluate the Sensata product to determine whether it
is fit for a particular purpose and suitable for the user’s application.
Sensata Technologies products are sold subject to Sensata’s Terms and Conditions of Sale which can be found at:
www.sensata.com/terms.htm
http://airpax.sensata.com/
Sensata Technologies Inc.
529 Pleasant Street
Attleboro, MA 02703, USA
Phone: +1 508-236-3287