MAP55 Series Datasheet by WEC

MAP55 Series AC—DC Power Supplies Key Features & Benefits POWER ‘ e SOLUTIONS S- PROTECTION o be‘ group belpowersolutions.com
Bel Power Solutions MAP55 Series of power supplies provides
reliable, tightly-regulated DC power for commercial and industrial
systems. Wide-range AC input and full international safety, EMI, and
ESD compliance ensure worldwide acceptance. All units bear the CE
Mark.
The MAP55 utilizes a thermally efficient U-channel chassis design.
Other mechanical design innovations include metric and SAE
mounting inserts on each mounting surface to provide integration
flexibility. Dual-mode connectors provide traditional terminal block
connections or popular single row Molex connector mating.
Single-output models feature wide-range output adjustability to meet
a wide variety of standard and user-specific output voltage
requirements.
RoHS Compliant
Wide Range Input for 110/220 VAC Applications
Meets EN55022, Conducted Class B Limits
Compact Footprint: 6.0 x 3.27 x 1.6 inch (152.4 x 83.1 x 40.6 mm)
Greater than 225000 Hours MTBF
Metric and SAE Mounting Inserts
1. SINGLE-OUTPUT MODEL SELECTION 2. MULTIPLE-OUTPUT MODEL SELECTION —55 W CONTINUOUS OUTPUT POWER b POWER e SOLUTIONS s PROTECTION o bel group belpowersolutions.com
2
MAP55 Series
tech.support@psbel.com
MODEL8
OUTPUT
VOLTAGE
MAX
OUTPUT
CURRENT
PEAK
OUTPUT
CURRENT1
LINE
REGULATION
LOAD
REGULATION
RIPPLE
&
NOISE2
INITIAL SETTING
ACCURACY
MAP40-1005G
5V
8A
11A
0.2%
±1.5%
1%
5.0V to 5.2V
MAP55-1012G6
12V/15V
5.0/4.0A3
5.8/4.7A3
0.2%
±1%
1%
12.0V to 12.2V
MAP55-1024G6
24V/28V
2.5/2.2A3
2.9/2.5A3
0.2%
1%
1%
23.8V to 24.2V
MODEL8
OUTPUT
VOLTAGE
OUTPUT
CURRENT
PEAK
OUTPUT
CURRENT4
LINE
REGULATION
LOAD
REGULATION
RIPPLE
&
NOISE2
INITIAL SETTING
ACCURACY
MAP55-4000G7
+5V
6A
8A
0.2%
2%
1%
5.0V to 5.2V
+12V
3A
5A
0.2%
2%
1%
11.6V to 12.4V
-5V
0.5A
1A5
0.5%
2%
1%
-4.8V to -5.2V
-12V
0.5A
1A5
0.5%
2%
1%
-11.6V to -12.4V
MAP55-4001G7
+5V
6A
8A
0.2%
2%
1%
5.0V to 5.2V
+24V
1.5A
2.5A
0.2%
2%
1%
23.0V to 24.9V
-12V
0.5A
1A5
0.5%
2%
1%
-11.6V to -12.4V
+12V
0.5A
1A5
0.5%
2%
1%
11.6V to 12.4V
MAP55-4002G7
+5V
6A
8A
0.2%
2%
1%
5.0V to 5.2V
+12V
3A
5A
0.2%
2%
1%
11.6V to 12.4V
-12V
0.5A
1A5
0.5%
2%
1%
-11.6V to -12.4V
+12V
0.5A
1A5
0.5%
2%
1%
11.6V to 12.4V
MAP55-4003G7
+5V
6A
8A
0.2%
2%
1%
5.0V to 5.2V
+15V
2.5A
3.5A
0.2%
2%
1%
14.6V to 15.4V
-5V
0.5A
1A5
0.5%
2%
1%
-4.8V to -5.2V
-15V
0.5A
1A5
0.5%
2%
1%
-14.4V to -15.6V
MAP55-4004G7
+5V
6A
8A
0.2%
2%
1%
5.0V to 5.2V
+24V
1.5A
2.5A
0.2%
2%
1%
23.0V to 24.9V
-15V
0.5A
1A5
0.5%
2%
1%
-14.5V to -15.5V
+15V
0.5A
1A5
0.5%
2%
1%
14.5V to 15.5V
1
Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
2
Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3
MAP55-1012 output currents are expressed as 12V/15V operation. MAP55-1024 output currents are expressed as 24V/28V operation.
4
Peak loads up to 65 watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 65 watts.
5
Maximum load on V3 or V4 could be 1 amp continuous if output V4 or V3 is unloaded.
6 Maximum 60 W with 150LFM (Linear Feet per Minute) air cooling or maximum 50 W with convection cooling.
7 Maximum 55 W with 200LFM (Linear Feet per Minute) air cooling or maximum total output power 45 W at 40°C ambient operating temperature
for models with no cover and 40 W for models with cover / convection cooling.
8 Non-G models use lead solder exemption.
3. INPUT SPECIFICATIONS 4. OUTPUTSPECIFICATIONS 5. INTERFACE SIGNALS & INTERNAL PROTECTION b POWER e SOLUTIONS s PROTECTION o bel group
MAP55 Series
3
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2016 Bel Power Solutions & Protection
BCD.00564_AD
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage - AC
Continuous input range
90
175
132
264
VAC
Input Frequency
AC input
47
63
Hz
Brown Out Protection
Lowest AC input voltage that regulation is maintained with full rated
loads
90
VAC
Hold-up Time
Nominal AC Input Voltage (115VAC), full rated load
20
ms
Input Current
90 VAC (55 W load)
1.6
ARMS
Input Protection
Non-user serviceable internally located AC input line fuse.
Inrush Surge Current
Internally limited by thermistor, Vin = 264 VAC (one cycle), 25°C
38
APK
Operating Frequency
Switching frequency of power supply (varies with load)
22
180
kHz
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Full load @ 115 VAC. Varies with distribution of loads among
outputs.
73% typical
Minimum Loads
MAP55-1012
MAP55-1024
MAP40-1005 and all multiple output models, main channel only
0.21
0.11
0.50
Amps
Ripple and Noise
Full load, 20 MHz bandwidth.
See Model Selection Chart
Output Power
Continuous output power, all multiple output models.
Peak output power (60 s maximum, 10% duty cycle), all multiple
output models.
55
65
Watts
Overshoot / Undershoot
Output voltage overshoot/undershoot at turn-on, V1, V2.
1
%
Regulation
Varies by output. Total regulation includes: line changes from 90-
132 VAC or 175-264 VAC, changes in load starting at 20% load and
changing to 100% load.
See Model Selection Chart
Transient Response
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output of multiple output
units.)
500
μs
Turn-on Delay
Time required for initial output voltage stabilization.
1
4
Sec
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%. (Nominal
rise time for MAP55-1024 is 36 msec.)
7
ms
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
MAP40-1005
MAP55-1012
MAP55-1024
Main output only of multiple output units.
5.5
17.5
32.0
5.6
6.8
19.7
36.0
6.8
V
Overload Protection
Fully protected against output overload and short circuit.
Automatic recovery upon removal of overload condition.
6. SAFETY, REGULATORY AND EMI SPECIFICATIONS 7. ENVIRONMENTAL SPECIFICATIONS 8. MECHANICAL SPECIFICATIONS / OPTIONS 9. CONNECTIONS b POWER e SOLUTIONS s PROTECTION o bel group belpowersolutions.com
4
MAP55 Series
tech.support@psbel.com
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
Approved to the latest edition of the following standards;
UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd.
Dielectric Withstand Voltage
Input to Chassis
Input to Output (tested by manufacturer only)
2121
4242
VDC
Electromagnetic Interference,
Conducted
FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
B
B
A
Class
Insulation Resistance
Input to output
7
MΩ
Leakage Current
Per EN60950, 264 VAC
500
μA
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Altitude
Operating
Non-operating
10k
40k
Feet
Operating Temperature
Derate linearly above 50°C by 2.5% per °C to a
maximum temperature of 70°C (with 200LFM)
At 100% load:
At 50% load:
0
0
50
70
°C
Storage Temperature
-40
85
°C
Temperature Coefficient
0°C to 70°C (after 15 minute warm-up)
±0.02
±0.03
%/°C
Relative Humidity
Non-condensing
5
95
%RH
Shock
Operating, peak acceleration
20
G
Vibration
Random vibration, 10Hz to 2kHz, 3 axis
6
GRMS
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Dimensions
152.4 x 83.1 x 40.6
6.00 x 3.27x 1.6
mm
in
Weight
0.55
1.1
kg
lb
Cover (Option)
Order the cover number 412-59584-G separately.
For convection cooled applications, derate output power to 40 watts
on multiple output units, 50 watts on MAP55-1012 and MAP55-1024
and 40 watts on MAP40-1005.
Dimensions:
152.4 x 83.1 x 45.0
6.00 x 3.27 x 1.77
mm
in
CONNECTOR
CONDITIONS / DESCRIPTION
Input & Output Connectors
6-32 screw wire clamps on 0.312" (7.9 mm) centers
0.045" (1.1 mm) square pins on 0.156" (3.4 mm) centers
Matting Connectors
Molex Series 2139, 6442, or 41695
Chassis
0.090" (2.3 mm) aluminum alloy, with clear finish
4 1 1370 1 0 1 E1 :| ” 1572 3 mm, 1 0 O 0 1,900 u 8 3 2r (831mm) 0 T52 |:| U 900 V1 00 [l '—| 0:..0 @VADJ, 500' I nszamm) | (1397mm) _. .— ozs | {6.4mm} ’— - O 9 V 055' a G) 1 w (27.1mm! ”a7- _ © Q (on 5mm 1 (Mm, 330%?” T V -------------- _ - _ T31 T32 mm PIN1 S‘agHg'égB 25 AC INPUT DC OUTPUT UNIVERSAL umzswnn wmswum MOUNT'NG M4 07 GH scmcmr Inclncw '“SW TfiRE'AE mm 1 mom 5 PLAcgsp comm“) mm m L w COM W v3 v4 WWW“) 017' 14.3mm DIATHRLI For more information on these products consult: Iech.support@psbel.com b POWER e SOLUTIONS s PROTECTION 0 Del group
MAP55 Series
5
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2016 Bel Power Solutions & Protection
BCD.00564_AD
Figure 1. Mechanical Drawing
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.