Slide 1 Slide 2 Slide 3 Slide 4 Slide 5 Slide 6 Slide 7 Slide 8 Slide 9 Slide 10 Slide 11 Slide 12 Slide 13 Slide 14 Slide 15 Slide 16 Slide 17 Product List
UHM- Slide15

In addition to eye pattern and impedance measurements, 3M has conducted extensive S Parameter testing and modeling. The plot shown here is the modeled differential insertion loss for the UHM socket mated to a standard 2mm CompactPCI® 5+2 HM Header. The curve indicates very low loss, that is less than 1dB for frequencies of greater than 4GHz.

PTM Published on: 2011-10-13