Texas Instruments 的 TCAN EVM User Guide 规格书

{if TEXAS INSTRUMENTS
Users Guide
TCAN Evaluation Module
ABSTRACT
This user guide details the TCAN10xx CAN (Controller Area Network) EVM transceiver operation. The
TCAN10xx CAN EVM is configurable for use with all TI CAN transceiver families: TCAN10xx, TCAN33x,
SN65HVD23x, SN65HVD25x, SN65HVD10x0, and SN65HVDA54x by replacing the transceiver and setting
jumpers on the EVM as outlined in this document. This user guide explains the EVM configurations for basic
CAN evaluation, various load and termination settings.
Table of Contents
1 Introduction.............................................................................................................................................................................2
1.1 Overview............................................................................................................................................................................ 2
1.2 CAN EVM...........................................................................................................................................................................2
2 EVM Setup and Operation......................................................................................................................................................5
2.1 Overview and Basic Operation Settings.............................................................................................................................5
2.2 Using CAN Bus Load, Termination, and Protection Configurations................................................................................... 7
2.3 Using Customer Installable I/O Options for Current Limiting, Pullup and Pulldown, Noise Filtering..................................8
3 CAN EVM Configuration for TCAN1042-Q1 (Factory Installed)..........................................................................................9
4 Revision History................................................................................................................................................................... 10
List of Figures
Figure 1-1. EVM PC Board.......................................................................................................................................................... 2
Figure 1-2. EVM Schematic.........................................................................................................................................................3
Figure 3-1. TCAN1042 Basic Block Diagram.............................................................................................................................. 9
List of Tables
Table 1-1. Jumper Connections................................................................................................................................................... 4
Table 2-1. JMP2 Pin Definitions...................................................................................................................................................5
Table 2-2. Bus Termination Configuration....................................................................................................................................7
Table 2-3. Protection and Filtering Configuration.........................................................................................................................7
Table 2-4. RC Filter and Protection Lists..................................................................................................................................... 8
Table 3-1. EVM Connection Settings for TCAN1042................................................................................................................... 9
Trademarks
All trademarks are the property of their respective owners.
www.ti.com Table of Contents
SLLU234A – FEBRUARY 2016 – REVISED MARCH 2021
Submit Document Feedback
TCAN Evaluation Module 1
Copyright © 2021 Texas Instruments Incorporated
I TEXAS INSTRUMENTS TEXAS INSTRUMEN s
1 Introduction
1.1 Overview
TI offers a broad portfolio of high speed (HS) CAN transceivers compatible with the ISO11898-2 high speed CAN
standards. These include 5-V VCC only, 3.3-V VCC only, 5-V VCC with I/O level shifting and galvanic-isolated CAN
transceivers. These CAN transceiver families include product mixes with varying features such as low-power
standby modes with and without wake up, silent modes, loop back, and diagnostic modes.
TI's CAN EVM helps designers evaluate the operation and performance of various TI CAN transceivers. It
also provides bus termination, bus filtering, and protection concepts. It is easily configured by the customer for
the TCAN10xx, TCAN33x, SN65HVD23x, SN65HVD25x, SN65HVD10x0, and SN65HVDA54x CAN transceiver
families as needed by jumper settings, simple soldering tasks, and replacement of standard components. A
separate EVM is available for the galvanic-isolated CAN transceiver family.
1.2 CAN EVM
The CAN EVM has simple connections to all necessary pins of the CAN transceiver device, and jumpers
where necessary to provide flexibility for device pin and CAN bus configuration. There are test points (loops)
for all main points where probing is necessary for evaluation such as GND, VCC, TXD, RXD, CANH, CANL,
pin 8 (mode pin), or pin 5 (various functions). The EVM supports many options for CAN bus configuration.
It is pre-configured with two 120-Ω resistors that are connected on the bus via jumpers: a single resistor is
used with the EVM as a terminated line end (CAN is defined for 120-Ω impedance twisted pair cable) or both
resistors in parallel for electrical measurements representing the 60-Ω load the transceiver “sees” in a properly
terminated network (that is, 120-Ω termination resistors at both ends of the cable). If the application requires
“split” termination, TVS diodes for protection, or Common Mode (CM) Choke, the EVM has footprints available
for this via customer installation of the desired components.
Figure 1-1 shows the EVM board image.
Figure 1-1. EVM PC Board
Introduction www.ti.com
2TCAN Evaluation Module SLLU234A – FEBRUARY 2016 – REVISED MARCH 2021
Submit Document Feedback
Copyright © 2021 Texas Instruments Incorporated
I TEXAS INSTRUMENTS
Figure 1-2 shows the EVM schematic.
Place near DUT Pint
Verify EIA 0603 size versus 0603
VCC
VCC
VCC
VCC
VCC
VCC
VRXD
VRXD
VCC
VCC
TP13
Test Point
TB1
2PIN_TERMINAL_BLOCK
1
2
1
JMP2
Header 10x1
TP9
Test Point
C7
DNI
L1
1
4
2
3
R17
0
R11
120
R14 0
C3
DNI
TP5
Test Point
R2
DNI
R4
0
C8
4.7uF
TP8
Test Point
R6
DNI
TP2
Test Point
C5
DNI
D3
LED
R1
4.7k
1
2
JMP4
1
2
JMP5
C4
DNI
C10
10uF
R20
330
TP10
Test Point
R7
DNI
R8
330 D2
DNI
1
2
3
TP7
Test Point
C1
DNI
TP11
Test Point
R5
DNI
C6
DNI
R16
330
TP4
Test Point
R19
0
R13 0
R15
DNI
R9 0
U1
TCAN10xx
TXD
1
GND
2
VCC
3
RXD
4VIO / NC 5
CANL 6
CANH 7
STB 8
TP6
Test Point
C11
1uF
C2
DNI
TP1
Test Point
TP12
Test Point
C12
.1uF
TP3
Test Point
C9
1uF
R12
120
R18
4.7k
1
JMP7
GND
CANH
CANL
GND
1
2
3
4
5
JMP6
R10 0
R3
0
1
4
JMP1
Header T 4pin
VCM
Figure 1-2. EVM Schematic
www.ti.com Introduction
SLLU234A – FEBRUARY 2016 – REVISED MARCH 2021
Submit Document Feedback
TCAN Evaluation Module 3
Copyright © 2021 Texas Instruments Incorporated
I TEXAS INSTRUMENTS
Table 1-1 lists the jumper connections for the EVM.
Table 1-1. Jumper Connections
Connection Type Description
JMP1 4-pin jumper Used for mode selection on pin 8 (4.7-kΩ pullup to VCC, 0-Ω pulldown to GND, customer-
installable pulldown for devices with slew rate control RS pin).
JMP2 10-pin header Connection for access to all critical digital I/O, supply, and GND for driving the CAN transceiver
externally with test equipment or interfaced to a processor EVM
JMP3 4-pin header CAN bus connection (CANH, CANL) and GND
JMP4 2-pin jumper
Connect 120-Ω CAN termination to the bus. Used separately for a single termination if EVM is at
end of the CAN bus and termination is not in the cable. Used in combination with JMP5 to get
to second CAN termination to represent the combined 60-Ω load for CAN transceiver parametric
measurement.
JMP5 2-pin jumper
Connect 120-Ω CAN termination to the bus. Used in combination with JMP4 to get to
second CAN termination to represent the combined 60-Ω load for CAN transceiver parametric
measurement.
JMP6 5-pin jumper
Functional use of pin 5. Options for use are:
spA) 4.7-kΩ pullup to VCC for transceiver with digital input on pin 5
spB) 0-Ω pulldown to GND for transceiver with digital input on pin 5
spC) Active split termination: for CAN transceiver with VREF or SPLIT pin where active split
termination is desired. Connect to VCM and populate the components R7/R15 and C4 as
required for the system.
spD) VRXD (VIO) for CAN transceivers with a separate VRXD (VIO) for I/O level shifting
TB1 2-pin jumper VCC supply and GND connection for the EVM
TP1
Test Point
TXD, Device pin 1 test point
TP2 CANH (bus) test point
TP3 Device pin 8 test point
TP4 CANH via 330-Ω serial resistor test point
TP5 CANL (bus) test point
TP6 CANL via 330-Ω serial resistor test point
TP7 RXD, Device pin 4 test point
TP8 Device pin 5 test point
TP9 VCC test point
TP10
GND test point
TP11
TP12
TP13
Introduction www.ti.com
4TCAN Evaluation Module SLLU234A – FEBRUARY 2016 – REVISED MARCH 2021
Submit Document Feedback
Copyright © 2021 Texas Instruments Incorporated
I TEXAS INSTRUMENTS
2 EVM Setup and Operation
This section describes the setup and operation of the EVM for parameter performance evaluation.
2.1 Overview and Basic Operation Settings
2.1.1 VCC Power Supply (TB1, TP9, or JMP2)
The basic setup of the CAN EVM uses a single power supply required to evaluate standard 5-V or 3.3-V
single-supply transceiver device performance. For single-supply transceivers, connect the 5- or 3.3-V VCC supply
to the TB1 jumper header, or the VCC and GND test-point loops. The power supplied should meet the required
specification of VCC for the transceiver being tested. LED D3 is used to indicate VCC presence.
2.1.2 I/O Power Supply VRXD or VIO (JMP2, JMP6 ,or TP8)
For devices with I/O level shifting, a second supply pin for the I/O or RXD pin is on pin 5 of the transceiver
device. A second power supply is needed to test one of these devices. Connect this power supply via JMP2,
JMP6, or TP8. Install a local buffering and decoupling capacitor at C6 if the EVM is used for one of these
devices.
2.1.3 Main Supply and I/O Header (JMP2)
All key I/O and supply GND functions are brought to this header. It may be used on either interface to test
equipment or a short cable could be made to connect to an existing customer-application board with a CAN
controller.
Table 2-1. JMP2 Pin Definitions
Pin Connection Description
1 MODE Pin 8 of transceiver, normally used for mode control, examples: SHDN, FAULT, RS, S, STB
2 TXD Pin 1 of transceiver, TXD (transmit data)
3 GND Pin 2 of transceiver, GND
4 GND Pin 2 of transceiver, GND
5 RXD Pin 4 of transceiver, RXD (receive data)
6 GND Pin 2 of transceiver, GND
7 VCC Pin 3 of transceiver, VCC
8 GND Pin 2 of transceiver, GND
9 P5 Pin 5 of transceiver, various functions depending on transceiver, examples: VREF, SPLIT, VRXD, VIO,
LBK, EN, AB, and No Connect (NC)
10 VRXD
Connects to Jumper JMP6 VRXD header to allow flexibility in using the device with power supply for
I/O on pin 5 of the transceiver
This header is arranged to provide a separate ground for each signal pair (TXD/GND and RXD/GND). If the
EVM is being used with lab equipment, connect separate cables to these main points via simple 2-pin header
connectors. If connecting the board to a processor-based system, connect a single cable with all power and
signals via a 10-pin header cable to this port.
2.1.4 TXD Input (JMP2 or TP1)
The TXD (pin 1) of the transceiver, transmit data is routed to JMP2 and TP1. The signal path to the JMP2 header
is pre-installed with a 0-Ω series resistor, R10.
2.1.5 RXD Output (JMP2 or TP7)
The RXD (pin 4) of the transceiver, receive data is routed to JMP2 and TP7. The signal path to the JMP2 header
is pre-installed with a 0-Ω series resistor, R13.
2.1.6 MODE Select or Pin 8 (JMP1, JMP2, or TP3)
Pin 8 of the transceiver is normally a mode control pin of the device. Pin 8 of the device is routed to JMP1,
JMP2, and TP7.
www.ti.com EVM Setup and Operation
SLLU234A – FEBRUARY 2016 – REVISED MARCH 2021
Submit Document Feedback
TCAN Evaluation Module 5
Copyright © 2021 Texas Instruments Incorporated
I TEXAS INSTRUMENTS
2.1.7 MODE - JMP1 Configurations (3-Way Jumper)
If using separate I/O inputs JMP1 is used to configure pin 8 to a pullup to VCC or pulldown to GND configuration.
For most devices, when pin 8 is pulled to GND, the device is in “normal” or high speed mode. R3 is pre-installed
with 0-Ω resistor to GND for this purpose. For most devices, when pin 8 is pulled to VCC the device is in a silent
or low power standby mode. Devices with slope control mode use the resistance to ground value to determine
the slope of the driver output. R2 is left open for customers who want to install a resistance to ground and use
slope mode.
2.1.8 JMP2 Configuration
Using header JMP2 which assumes all the digital I/O signals, VCC, GND are routed to an external system.
Ensure that the MODE (JMP1) jumper settings are not conflicting with signals to JMP2.
2.1.9 TP3 Configuration
This connects directly to device pin 8. Ensure JMP1 configuration is not conflicting if TP3 is used as the input
connection.
2.1.10 Pin 5 (JMP6, JMP2 or TP8)
Pin 5 of the transceiver have various uses depending on the transceiver. Examples are VREF, SPLIT, VRXD, VIO,
LBK, EN, AB and No Connect (NC). Pin 5 of the device is routed to JMP6, JMP2 and TP8.
2.1.11 Pin 5 – JMP6 Configurations (4-Way Jumper)
If using separate I/O inputs, JMP6 is used to configure pin 5 to: pullup to VCC, pulldown to GND, VRXD or VIO
supply input, or VREF or SPLIT termination output.
VREF or SPLIT termination: If the device and application support split termination, set JMP6 to VCM (V
common mode) to drive the VREF or SPLIT pin common mode stabilizing voltage output to the center tap of
the split termination capacitor. Install these components on the EVM as outlined in the CAN bus termination
section.
No Connection: If the device and application require no use of pin 5, leave it open. If the device has the
VREF or SPLIT pin but the application is not using the pin for split termination then add a capacitor on C6 to
improve EMC performance.
2nd Mode or Control Input: if the device and application use pin 5 as a second mode or control pin, then set
JMP6 as either a pullup to VCC or pulldown to GND, as necessary.
I/O and RXD level-shifting supply: if the device and application used with VIO or VRXD to level shift I/O pins
on the transceiver then set JMP6 to VRXD connecting pin 5 of the device to the VRXD pin on JMP2. Install local
buffering and bypass capacitor C6.
2.1.12 JMP2 Configuration
Using header JMP2 assumes all the digital I/O signals, VCC, and GND are routed to an external system. Ensure
that pin 5 (JMP6) jumper settings are not conflicting with signals to JMP2. For power supply VRXD, set the jumper
to route JMP2 supply input to the transceiver pin.
2.1.13 TP8 Configuration
This connects directly to device pin 5. Ensure JMP6 configuration is not conflicting if TP8 is used as an input
connection.
EVM Setup and Operation www.ti.com
6TCAN Evaluation Module SLLU234A – FEBRUARY 2016 – REVISED MARCH 2021
Submit Document Feedback
Copyright © 2021 Texas Instruments Incorporated
I TEXAS INSTRUMENTS
2.2 Using CAN Bus Load, Termination, and Protection Configurations
The CAN EVM is populated with two 120-Ω power resistors selectable via jumpers between CANH and CANL.
When using one resistor, the EVM is used as a terminated end of a bus. For electrical measurements to
represent the total loading of the bus, use both 120-Ω resistors in parallel to give the standard 60-Ω load for
parametric measurement. The EVM also has footprints for split termination, if needed for the application. Table
2-2 summarizes how to use these termination options. If using split termination, match the resistors. Calculate
the common mode filter frequency using: fC = 1 / (2πRC). Normally, the split capacitance is in the range of 4.7
nF to 100 nF. Keep in mind this is the common-mode filter frequency, not a differential filter that impacts the
differential CAN signal directly.
Table 2-2. Bus Termination Configuration
Termination Configuration 120-Ω Resistors Split Termination Footprints Split Termination
Footprints
JMP4 JMP5 R7 R15 C4
Standard termination (120 Ω) shorted open N/A N/A N/A
60-Ω load - electrical parameterics shorted shorted
Split termination (common mode stabilization) open open 60 Ω 60 Ω populated
The EVM also has footprints for various protection schemes to enhance robustness for extreme system-level
EMC requirements. Table 2-3 summarizes these options.
Table 2-3. Protection and Filtering Configuration
Configuration Footprint Reference Use Case Population and Description
Series resistors or common
mode choke
R9/R14 or L1 (common
footprint)
Direct CAN transceiver to bus
connection
R9 and R14 populated with 0 Ω
(default population)
Series resistance protection, CAN
transceiver to bus connection
R9 and R14 populated with MELF
resistor as necessary for harsh EMC
environment
CM choke (bus filter)
L1 populated with CM choke to filter
noise as necessary for harsh EMC
environment
Bus filtering caps transient
protection C2/C7 Bus filter
Filter noise as necessary for harsh
EMC environment. Use filter caps in
combination with L1 CM choke.
C2/C7 or D1/D2 Transient and ESD protection
To add extra protection for system
level transients and ESD protection,
TVS diode population option via
D1/D2 footprint or varistor population
via C2/C7 footprint.
www.ti.com EVM Setup and Operation
SLLU234A – FEBRUARY 2016 – REVISED MARCH 2021
Submit Document Feedback
TCAN Evaluation Module 7
Copyright © 2021 Texas Instruments Incorporated
I TEXAS INSTRUMENTS
2.3 Using Customer Installable I/O Options for Current Limiting, Pullup and Pulldown, Noise
Filtering
The CAN EVM has footprints on the PCB for the installation of various filtering and protection options to adapt
the EVM to match CAN network topology requirements if the EVM is being used as a CAN node.
Each digital input or output pin has footprints allowing for series current-limiting resistors (default populated with
0 Ω), pullup or down resistors (depending on pin use), and a capacitor to GND which allows for RC filters when
configured with a series resistor. Table 2-4 lists these features for each of the digital input and output pins of the
EVM. Replace or populate the RC components as necessary for the application.
Table 2-4. RC Filter and Protection Lists
Device Pin Jumperable Series R Pullup and
Pulldown C to GND Description
No. Description Type Pullup Pulldown
1 TXD Input N/A N/A R10 R6 PU C3
2 RXD Output N/A N/A R13 R5 PU C5
5
NC No Connect N/A N/A N/A N/A N/A
SHDN Input R18 (JMP6) R19 (JMP6) R17 N/A C6
FAULT Output N/A N/A R17 N/A C4/C6
VREF and
SPLIT Output N/A N/A R17 N/A C4/C6
Split termination: JMP6 to
route output to split termination
center point capacitor C4. EMC
for systems not using split
termination: C6 to GND.
VRXD and VIO Supply Input N/A N/A R17 N/A C9/C6
Use TM6, JMP6, and JMP2
as necessary to provide supply
input.
AB, EN, and
LBK Input R18 (JMP6) R19 (JMP6) R17 N/A C6
8S, RS, STB Input R1 (JMP1) R2/R3
(JMP1) R4 N/A C1
R2 pulldown to GND (JMP1)
user-installable for use with slope
mode on devices with RS pin.
NC No Connect N/A N/A N/A N/A N/A
EVM Setup and Operation www.ti.com
8TCAN Evaluation Module SLLU234A – FEBRUARY 2016 – REVISED MARCH 2021
Submit Document Feedback
Copyright © 2021 Texas Instruments Incorporated
I TEXAS INSTRUMENTS @@
3 CAN EVM Configuration for TCAN1042-Q1 (Factory Installed)
The TCAN10xx family of devices interface CAN protocol controllers with the physical bus in accordance to
the ISO 11898 standard. These devices are compatible with the ISO 11898 High Speed CAN (Controller Area
Network) Physical Layer standards: 11898-2. Standard versions are designed for data rates of 1 megabit per
second (Mbps) in CAN networks and additional devices are designed to meet at least 2 Mbps in CAN FD
networks. The devices include many protection features providing device and CAN network robustness.
6
7
OTP
UVP
Mode
Select
4
8
Logic
Output
TXD
STB
RXD
CANH
CANL
GND
5
NC or VIO
3
VCC
1
2
VCC or VIO
VCC or VIO
Dominant
Time-Out
VCC or VIO
WUP
Monitor
MUX
Low-Power Receiver
Figure 3-1. TCAN1042 Basic Block Diagram
Table 3-1. EVM Connection Settings for TCAN1042
Connection Description
JMP1 Mode selection: Pullup to VCC for silent mode, pulldown to GND for normal mode
JMP2 Connection for access to all critical digital I/O, supply, and GND if being externally driven by test equipment or interfaced
to a processor EVM. Note: ensure that JMP1, JMP6, and TB1 settings do not conflict with JMP2, if it is used.
JMP3 CAN bus connection (CANH, CANL) and GND as necessary if interfacing EVM to a CAN network
JMP4 Connect if necessary for a single CAN network termination
JMP5 Connect if necessary for in parallel with JMP4 to get a 60-Ω load to measure CAN parametrics
JMP6 TCAN1042 VIO - Level-shifting for applications that require 3.3-V operation. Connect to 5-V supply for 5-V applications
and 3.3-V for 3.3-V applications.
www.ti.com CAN EVM Configuration for TCAN1042-Q1 (Factory Installed)
SLLU234A – FEBRUARY 2016 – REVISED MARCH 2021
Submit Document Feedback
TCAN Evaluation Module 9
Copyright © 2021 Texas Instruments Incorporated
I TEXAS INSTRUMENTS
4 Revision History
NOTE: Page numbers for previous revisions may differ from page numbers in the current version.
Changes from Revision * (February 2016) to Revision A (March 2021) Page
Updated the numbering format for tables, figures, and cross-references throughout the document. ................1
Changed section title to CAN EVM Configuration for TCAN1042-Q1 (Factory Installed).. ................................9
Revision History www.ti.com
10 TCAN Evaluation Module SLLU234A – FEBRUARY 2016 – REVISED MARCH 2021
Submit Document Feedback
Copyright © 2021 Texas Instruments Incorporated
WARNING
STANDARD TERMS FOR EVALUATION MODULES
1. Delivery: TI delivers TI evaluation boards, kits, or modules, including any accompanying demonstration software, components, and/or
documentation which may be provided together or separately (collectively, an “EVM” or “EVMs”) to the User (“User”) in accordance
with the terms set forth herein. User's acceptance of the EVM is expressly subject to the following terms.
1.1 EVMs are intended solely for product or software developers for use in a research and development setting to facilitate feasibility
evaluation, experimentation, or scientific analysis of TI semiconductors products. EVMs have no direct function and are not
finished products. EVMs shall not be directly or indirectly assembled as a part or subassembly in any finished product. For
clarification, any software or software tools provided with the EVM (“Software”) shall not be subject to the terms and conditions
set forth herein but rather shall be subject to the applicable terms that accompany such Software
1.2 EVMs are not intended for consumer or household use. EVMs may not be sold, sublicensed, leased, rented, loaned, assigned,
or otherwise distributed for commercial purposes by Users, in whole or in part, or used in any finished product or production
system.
2Limited Warranty and Related Remedies/Disclaimers:
2.1 These terms do not apply to Software. The warranty, if any, for Software is covered in the applicable Software License
Agreement.
2.2 TI warrants that the TI EVM will conform to TI's published specifications for ninety (90) days after the date TI delivers such EVM
to User. Notwithstanding the foregoing, TI shall not be liable for a nonconforming EVM if (a) the nonconformity was caused by
neglect, misuse or mistreatment by an entity other than TI, including improper installation or testing, or for any EVMs that have
been altered or modified in any way by an entity other than TI, (b) the nonconformity resulted from User's design, specifications
or instructions for such EVMs or improper system design, or (c) User has not paid on time. Testing and other quality control
techniques are used to the extent TI deems necessary. TI does not test all parameters of each EVM.
User's claims against TI under this Section 2 are void if User fails to notify TI of any apparent defects in the EVMs within ten (10)
business days after delivery, or of any hidden defects with ten (10) business days after the defect has been detected.
2.3 TI's sole liability shall be at its option to repair or replace EVMs that fail to conform to the warranty set forth above, or credit
User's account for such EVM. TI's liability under this warranty shall be limited to EVMs that are returned during the warranty
period to the address designated by TI and that are determined by TI not to conform to such warranty. If TI elects to repair or
replace such EVM, TI shall have a reasonable time to repair such EVM or provide replacements. Repaired EVMs shall be
warranted for the remainder of the original warranty period. Replaced EVMs shall be warranted for a new full ninety (90) day
warranty period.
WARNING
Evaluation Kits are intended solely for use by technically qualified,
professional electronics experts who are familiar with the dangers
and application risks associated with handling electrical mechanical
components, systems, and subsystems.
User shall operate the Evaluation Kit within TI’s recommended
guidelines and any applicable legal or environmental requirements
as well as reasonable and customary safeguards. Failure to set up
and/or operate the Evaluation Kit within TI’s recommended
guidelines may result in personal injury or death or property
damage. Proper set up entails following TI’s instructions for
electrical ratings of interface circuits such as input, output and
electrical loads.
NOTE:
EXPOSURE TO ELECTROSTATIC DISCHARGE (ESD) MAY CAUSE DEGREDATION OR FAILURE OF THE EVALUATION
KIT; TI RECOMMENDS STORAGE OF THE EVALUATION KIT IN A PROTECTIVE ESD BAG.
www.ti.com
2
3Regulatory Notices:
3.1 United States
3.1.1 Notice applicable to EVMs not FCC-Approved:
FCC NOTICE: This kit is designed to allow product developers to evaluate electronic components, circuitry, or software
associated with the kit to determine whether to incorporate such items in a finished product and software developers to write
software applications for use with the end product. This kit is not a finished product and when assembled may not be resold or
otherwise marketed unless all required FCC equipment authorizations are first obtained. Operation is subject to the condition
that this product not cause harmful interference to licensed radio stations and that this product accept harmful interference.
Unless the assembled kit is designed to operate under part 15, part 18 or part 95 of this chapter, the operator of the kit must
operate under the authority of an FCC license holder or must secure an experimental authorization under part 5 of this chapter.
3.1.2 For EVMs annotated as FCC – FEDERAL COMMUNICATIONS COMMISSION Part 15 Compliant:
CAUTION
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) this device must accept any interference received, including interference that may cause
undesired operation.
Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to
operate the equipment.
FCC Interference Statement for Class A EVM devices
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is
operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to
correct the interference at his own expense.
FCC Interference Statement for Class B EVM devices
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of
the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance
with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference
will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more
of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
3.2 Canada
3.2.1 For EVMs issued with an Industry Canada Certificate of Conformance to RSS-210 or RSS-247
Concerning EVMs Including Radio Transmitters:
This device complies with Industry Canada license-exempt RSSs. Operation is subject to the following two conditions:
(1) this device may not cause interference, and (2) this device must accept any interference, including interference that may
cause undesired operation of the device.
Concernant les EVMs avec appareils radio:
Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence. L'exploitation
est autorisée aux deux conditions suivantes: (1) l'appareil ne doit pas produire de brouillage, et (2) l'utilisateur de l'appareil doit
accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d'en compromettre le fonctionnement.
Concerning EVMs Including Detachable Antennas:
Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser)
gain approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type
and its gain should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for
successful communication. This radio transmitter has been approved by Industry Canada to operate with the antenna types
listed in the user guide with the maximum permissible gain and required antenna impedance for each antenna type indicated.
Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited
for use with this device.
www.ti.com
3
Concernant les EVMs avec antennes détachables
Conformément à la réglementation d'Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d'un type et
d'un gain maximal (ou inférieur) approuvé pour l'émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage
radioélectrique à l'intention des autres utilisateurs, il faut choisir le type d'antenne et son gain de sorte que la puissance isotrope
rayonnée équivalente (p.i.r.e.) ne dépasse pas l'intensité nécessaire à l'établissement d'une communication satisfaisante. Le
présent émetteur radio a été approuvé par Industrie Canada pour fonctionner avec les types d'antenne énumérés dans le
manuel d’usage et ayant un gain admissible maximal et l'impédance requise pour chaque type d'antenne. Les types d'antenne
non inclus dans cette liste, ou dont le gain est supérieur au gain maximal indiqué, sont strictement interdits pour l'exploitation de
l'émetteur
3.3 Japan
3.3.1 Notice for EVMs delivered in Japan: Please see http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page 日本国内に
輸入される評価用キット、ボードについては、次のところをご覧ください。
http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_01.page
3.3.2 Notice for Users of EVMs Considered “Radio Frequency Products” in Japan: EVMs entering Japan may not be certified
by TI as conforming to Technical Regulations of Radio Law of Japan.
If User uses EVMs in Japan, not certified to Technical Regulations of Radio Law of Japan, User is required to follow the
instructions set forth by Radio Law of Japan, which includes, but is not limited to, the instructions below with respect to EVMs
(which for the avoidance of doubt are stated strictly for convenience and should be verified by User):
1. Use EVMs in a shielded room or any other test facility as defined in the notification #173 issued by Ministry of Internal
Affairs and Communications on March 28, 2006, based on Sub-section 1.1 of Article 6 of the Ministry’s Rule for
Enforcement of Radio Law of Japan,
2. Use EVMs only after User obtains the license of Test Radio Station as provided in Radio Law of Japan with respect to
EVMs, or
3. Use of EVMs only after User obtains the Technical Regulations Conformity Certification as provided in Radio Law of Japan
with respect to EVMs. Also, do not transfer EVMs, unless User gives the same notice above to the transferee. Please note
that if User does not follow the instructions above, User will be subject to penalties of Radio Law of Japan.
【無線電波を送信する製品の開発キットをお使いになる際の注意事項】 開発キットの中には技術基準適合証明を受けて
いないものがあります。 技術適合証明を受けていないもののご使用に際しては、電波法遵守のため、以下のいずれかの
措置を取っていただく必要がありますのでご注意ください。
1. 電波法施行規則第6条第1項第1号に基づく平成18328日総務省告示第173号で定められた電波暗室等の試験設備でご使用
いただく。
2. 実験局の免許を取得後ご使用いただく。
3. 技術基準適合証明を取得後ご使用いただく。
なお、本製品は、上記の「ご使用にあたっての注意」を譲渡先、移転先に通知しない限り、譲渡、移転できないものとします。
上記を遵守頂けない場合は、電波法の罰則が適用される可能性があることをご留意ください。 日本テキサス・イ
ンスツルメンツ株式会社
東京都新宿区西新宿6丁目24番1号
西新宿三井ビル
3.3.3 Notice for EVMs for Power Line Communication: Please see http://www.tij.co.jp/lsds/ti_ja/general/eStore/notice_02.page
電力線搬送波通信についての開発キットをお使いになる際の注意事項については、次のところをご覧ください。http:/
/www.tij.co.jp/lsds/ti_ja/general/eStore/notice_02.page
3.4 European Union
3.4.1 For EVMs subject to EU Directive 2014/30/EU (Electromagnetic Compatibility Directive):
This is a class A product intended for use in environments other than domestic environments that are connected to a
low-voltage power-supply network that supplies buildings used for domestic purposes. In a domestic environment this
product may cause radio interference in which case the user may be required to take adequate measures.
www.ti.com
4
4EVM Use Restrictions and Warnings:
4.1 EVMS ARE NOT FOR USE IN FUNCTIONAL SAFETY AND/OR SAFETY CRITICAL EVALUATIONS, INCLUDING BUT NOT
LIMITED TO EVALUATIONS OF LIFE SUPPORT APPLICATIONS.
4.2 User must read and apply the user guide and other available documentation provided by TI regarding the EVM prior to handling
or using the EVM, including without limitation any warning or restriction notices. The notices contain important safety information
related to, for example, temperatures and voltages.
4.3 Safety-Related Warnings and Restrictions:
4.3.1 User shall operate the EVM within TI’s recommended specifications and environmental considerations stated in the user
guide, other available documentation provided by TI, and any other applicable requirements and employ reasonable and
customary safeguards. Exceeding the specified performance ratings and specifications (including but not limited to input
and output voltage, current, power, and environmental ranges) for the EVM may cause personal injury or death, or
property damage. If there are questions concerning performance ratings and specifications, User should contact a TI
field representative prior to connecting interface electronics including input power and intended loads. Any loads applied
outside of the specified output range may also result in unintended and/or inaccurate operation and/or possible
permanent damage to the EVM and/or interface electronics. Please consult the EVM user guide prior to connecting any
load to the EVM output. If there is uncertainty as to the load specification, please contact a TI field representative.
During normal operation, even with the inputs and outputs kept within the specified allowable ranges, some circuit
components may have elevated case temperatures. These components include but are not limited to linear regulators,
switching transistors, pass transistors, current sense resistors, and heat sinks, which can be identified using the
information in the associated documentation. When working with the EVM, please be aware that the EVM may become
very warm.
4.3.2 EVMs are intended solely for use by technically qualified, professional electronics experts who are familiar with the
dangers and application risks associated with handling electrical mechanical components, systems, and subsystems.
User assumes all responsibility and liability for proper and safe handling and use of the EVM by User or its employees,
affiliates, contractors or designees. User assumes all responsibility and liability to ensure that any interfaces (electronic
and/or mechanical) between the EVM and any human body are designed with suitable isolation and means to safely
limit accessible leakage currents to minimize the risk of electrical shock hazard. User assumes all responsibility and
liability for any improper or unsafe handling or use of the EVM by User or its employees, affiliates, contractors or
designees.
4.4 User assumes all responsibility and liability to determine whether the EVM is subject to any applicable international, federal,
state, or local laws and regulations related to User’s handling and use of the EVM and, if applicable, User assumes all
responsibility and liability for compliance in all respects with such laws and regulations. User assumes all responsibility and
liability for proper disposal and recycling of the EVM consistent with all applicable international, federal, state, and local
requirements.
5. Accuracy of Information: To the extent TI provides information on the availability and function of EVMs, TI attempts to be as accurate
as possible. However, TI does not warrant the accuracy of EVM descriptions, EVM availability or other information on its websites as
accurate, complete, reliable, current, or error-free.
6. Disclaimers:
6.1 EXCEPT AS SET FORTH ABOVE, EVMS AND ANY MATERIALS PROVIDED WITH THE EVM (INCLUDING, BUT NOT
LIMITED TO, REFERENCE DESIGNS AND THE DESIGN OF THE EVM ITSELF) ARE PROVIDED "AS IS" AND "WITH ALL
FAULTS." TI DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, REGARDING SUCH ITEMS, INCLUDING BUT
NOT LIMITED TO ANY EPIDEMIC FAILURE WARRANTY OR IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF ANY THIRD PARTY PATENTS, COPYRIGHTS, TRADE
SECRETS OR OTHER INTELLECTUAL PROPERTY RIGHTS.
6.2 EXCEPT FOR THE LIMITED RIGHT TO USE THE EVM SET FORTH HEREIN, NOTHING IN THESE TERMS SHALL BE
CONSTRUED AS GRANTING OR CONFERRING ANY RIGHTS BY LICENSE, PATENT, OR ANY OTHER INDUSTRIAL OR
INTELLECTUAL PROPERTY RIGHT OF TI, ITS SUPPLIERS/LICENSORS OR ANY OTHER THIRD PARTY, TO USE THE
EVM IN ANY FINISHED END-USER OR READY-TO-USE FINAL PRODUCT, OR FOR ANY INVENTION, DISCOVERY OR
IMPROVEMENT, REGARDLESS OF WHEN MADE, CONCEIVED OR ACQUIRED.
7. USER'S INDEMNITY OBLIGATIONS AND REPRESENTATIONS. USER WILL DEFEND, INDEMNIFY AND HOLD TI, ITS
LICENSORS AND THEIR REPRESENTATIVES HARMLESS FROM AND AGAINST ANY AND ALL CLAIMS, DAMAGES, LOSSES,
EXPENSES, COSTS AND LIABILITIES (COLLECTIVELY, "CLAIMS") ARISING OUT OF OR IN CONNECTION WITH ANY
HANDLING OR USE OF THE EVM THAT IS NOT IN ACCORDANCE WITH THESE TERMS. THIS OBLIGATION SHALL APPLY
WHETHER CLAIMS ARISE UNDER STATUTE, REGULATION, OR THE LAW OF TORT, CONTRACT OR ANY OTHER LEGAL
THEORY, AND EVEN IF THE EVM FAILS TO PERFORM AS DESCRIBED OR EXPECTED.
www.ti.com
5
8. Limitations on Damages and Liability:
8.1 General Limitations. IN NO EVENT SHALL TI BE LIABLE FOR ANY SPECIAL, COLLATERAL, INDIRECT, PUNITIVE,
INCIDENTAL, CONSEQUENTIAL, OR EXEMPLARY DAMAGES IN CONNECTION WITH OR ARISING OUT OF THESE
TERMS OR THE USE OF THE EVMS , REGARDLESS OF WHETHER TI HAS BEEN ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. EXCLUDED DAMAGES INCLUDE, BUT ARE NOT LIMITED TO, COST OF REMOVAL OR
REINSTALLATION, ANCILLARY COSTS TO THE PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES, RETESTING,
OUTSIDE COMPUTER TIME, LABOR COSTS, LOSS OF GOODWILL, LOSS OF PROFITS, LOSS OF SAVINGS, LOSS OF
USE, LOSS OF DATA, OR BUSINESS INTERRUPTION. NO CLAIM, SUIT OR ACTION SHALL BE BROUGHT AGAINST TI
MORE THAN TWELVE (12) MONTHS AFTER THE EVENT THAT GAVE RISE TO THE CAUSE OF ACTION HAS
OCCURRED.
8.2 Specific Limitations. IN NO EVENT SHALL TI'S AGGREGATE LIABILITY FROM ANY USE OF AN EVM PROVIDED
HEREUNDER, INCLUDING FROM ANY WARRANTY, INDEMITY OR OTHER OBLIGATION ARISING OUT OF OR IN
CONNECTION WITH THESE TERMS, , EXCEED THE TOTAL AMOUNT PAID TO TI BY USER FOR THE PARTICULAR
EVM(S) AT ISSUE DURING THE PRIOR TWELVE (12) MONTHS WITH RESPECT TO WHICH LOSSES OR DAMAGES ARE
CLAIMED. THE EXISTENCE OF MORE THAN ONE CLAIM SHALL NOT ENLARGE OR EXTEND THIS LIMIT.
9. Return Policy. Except as otherwise provided, TI does not offer any refunds, returns, or exchanges. Furthermore, no return of EVM(s)
will be accepted if the package has been opened and no return of the EVM(s) will be accepted if they are damaged or otherwise not in
a resalable condition. If User feels it has been incorrectly charged for the EVM(s) it ordered or that delivery violates the applicable
order, User should contact TI. All refunds will be made in full within thirty (30) working days from the return of the components(s),
excluding any postage or packaging costs.
10. Governing Law: These terms and conditions shall be governed by and interpreted in accordance with the laws of the State of Texas,
without reference to conflict-of-laws principles. User agrees that non-exclusive jurisdiction for any dispute arising out of or relating to
these terms and conditions lies within courts located in the State of Texas and consents to venue in Dallas County, Texas.
Notwithstanding the foregoing, any judgment may be enforced in any United States or foreign court, and TI may seek injunctive relief
in any United States or foreign court.
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2019, Texas Instruments Incorporated
IMPORTANT NOTICE AND DISCLAIMER
TI PROVIDES TECHNICAL AND RELIABILITY DATA (INCLUDING DATASHEETS), DESIGN RESOURCES (INCLUDING REFERENCE
DESIGNS), APPLICATION OR OTHER DESIGN ADVICE, WEB TOOLS, SAFETY INFORMATION, AND OTHER RESOURCES “AS IS”
AND WITH ALL FAULTS, AND DISCLAIMS ALL WARRANTIES, EXPRESS AND IMPLIED, INCLUDING WITHOUT LIMITATION ANY
IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR NON-INFRINGEMENT OF THIRD
PARTY INTELLECTUAL PROPERTY RIGHTS.
These resources are intended for skilled developers designing with TI products. You are solely responsible for (1) selecting the appropriate
TI products for your application, (2) designing, validating and testing your application, and (3) ensuring your application meets applicable
standards, and any other safety, security, or other requirements. These resources are subject to change without notice. TI grants you
permission to use these resources only for development of an application that uses the TI products described in the resource. Other
reproduction and display of these resources is prohibited. No license is granted to any other TI intellectual property right or to any third party
intellectual property right. TI disclaims responsibility for, and you will fully indemnify TI and its representatives against, any claims, damages,
costs, losses, and liabilities arising out of your use of these resources.
TI’s products are provided subject to TI’s Terms of Sale (https:www.ti.com/legal/termsofsale.html) or other applicable terms available either
on ti.com or provided in conjunction with such TI products. TI’s provision of these resources does not expand or otherwise alter TI’s
applicable warranties or warranty disclaimers for TI products.IMPORTANT NOTICE
Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265
Copyright © 2021, Texas Instruments Incorporated