Phoenix Contact 的 2700091 规格书

l phoenixconlamnegproducls I.-..--0-00- [fl'c’gfir't'c’é 0-1 INSPIRING INNOVATIONS
1Description
Connection element with spring-cage terminal
blocks for base mounting
PSD-S CE-SM SPRING
© PHOENIX CONTACT
Data sheet
This connection element is provided as a component of a
modular signal tower and facilitates the electrical connec-
tion of the signal tower.
According to your requirements, a signal tower may com-
prise any combination of up to five signal elements. You
may use up to five optical signal elements or up to four opti-
cal and one audible signal element.
An audible signal element can be used as top element only.
A bayonet locking system establishes the mechanical and
electrical connection between the elements.
Mounting elements for base or tube mounting can be used
to mount the signal tower.
Features
Connection element for the assembly on a mounting
surface (base), an outlet box or an angle (see accesso-
ries)
Spring-cage connection
Degree of protection: IP65, when mounted
Make sure you always use the latest documentation.
It can be downloaded from the product at phoenixcontact.net/products.
7957_en_02 2015-05-04
PSD-S CE-SM SPRING
7957_en_02 PHOENIX CONTACT 2
2Table of contents
1 Description .............................................................................................................................. 1
2 Table of contents ..................................................................................................................... 2
3 Ordering data .......................................................................................................................... 3
4 Technical data ......................................................................................................................... 3
5 Mounting the connection element............................................................................................ 4
6 Connecting the cables............................................................................................................. 5
7 Example of a signal tower........................................................................................................ 5
8 Assembly notes for a signal tower ........................................................................................... 5
PSD-S CE-SM SPRING
7957_en_02 PHOENIX CONTACT 3
Description Type Order No. Pcs./Pkt.
Connection element with spring-cage terminal blocks for base mounting PSD-S CE-SM SPRING 2700091 1
3Ordering data
Accessories Type Order No. Pcs./Pkt.
Outlet box with lateral cable entry for floor and base mounting PSD-S ME OB 2700153 1
Angle for floor mounting, black PSD-S ME BR-SM 2700144 1
Angle for single-sided floor mounting, concealed cable routing, black PSD-S ME BR-SM/1S 2700160 1
Angle for two-sided floor mounting, concealed cable routing, black PSD-S ME BR-SM/2S 2700161 1
4 Technical data
Dimensions (in mm)
Diameter 69 mm
Height 27 mm
26,5
Ø70
Ø69
Ø 4,2
21,5 18 3
16
General data
Material PA-GF
Color black
Weight 75 g
Ambient temperature (operation) -30 °C ... 50 °C
Degree of protection IP65, when installed
Mounting position any
Mounting type Base mounting
PSD-S CE-SM SPRING
7957_en_02 PHOENIX CONTACT 4
5 Mounting the connection element
Install the connection element directly on a flat mounting
surface, on a contact box or an angle. The possible options
are indicated in the ordering data under accessories.
For the mounting the connection element, proceed as de-
scribed in the package slip.
For the connection of cables, proceed as described in the
package slip.
Connection Rubber seal pre-installed for each element
Number of mountable signal elements max. 5
Scope of delivery End cover and seal
General data
Connection data (without ferrule)
Connection method Spring-cage connection
Conductor cross section, stranded 0.5 mm² ... 1.5 mm²
Conductor cross section, stranded [AWG] 20 - 15
Stripping length 7 mm
Connection data (With ferrule)
Connection method Spring-cage connection
Conductor cross section, stranded 0.25 mm² ... 1.5 mm²
Conductor cross section, stranded [AWG] 23 - 15
Stripping length 7 mm
Connection data (solid)
Connection method Spring-cage connection
Conductor cross section, solid 0.5 mm² ... 1.5 mm²
Conductor cross section, solid [AWG] 20 - 15
Stripping length 7 mm
Approvals / conformities
Conformance with EMC directive 2004/108/EC and for low-voltage directive 2006/95/EC
For the latest approvals, please visit phoenixcontact.net/products.
Please refer to the package list for connection
options. It is enclosed with the connection ele-
ment and can be downloaded from the inter-
net at phoenixcontact.net/products.
PSD-S CE-SM SPRING
7957_en_02 5
PHOENIX CONTACT GmbH & Co. KG • 32823 Blomberg • Germany
phoenixcontact.com
6 Connecting the cables
Bild 1 Connections in the connection element
7 Example of a signal tower
Bild 2 Example of a signal tower
Key:
1Audible signal element
2Optical signal element
3Connection element
4Assembly element
8 Assembly notes for a signal tower
Only use a maximum of five elements within a signal to-
wer.
Use only one audible element in a signal tower and po-
sition this element on top.
When connecting the bayonet locking, please note the
markings (see "Assembly of the individual elements" in
the data sheets of the signal elements).
NOTE:
When working on the connection element,
disconnect the power to the signal tower!
Connection Meaning
0 Reference potential (GND, N)
1 Control of the signal element 1
2 Control of the signal element 2
3 Control of the signal element 3
4 Control of the signal element 4
5 Control of the signal element 5
When using the audible elements "siren ele-
ment, 7 tones..." or "voice output element",
several control lines are needed for the audib-
le element, as the case may be. In this case,
please note the entries in the corresponding
data sheet or in the package slip.
1
2
3
4
5
0
1
2
3
4