Teledyne LeCroy 的 WaveAce™ 1000, 2000 Factsheet 规格书

LeCroy
Debug with Confidence
40 MHz300 MHz
Tools for Improved Debugging
Long Capture 1 Mpts/Ch and 2 Mpts
interleaved to capture more time and
show more waveform details
Math and Measure 4 basic math
functions plus FFT and 32 automatic
measurement parameters
Connectivity – USB for mass storage,
printing and PC control plus LAN for
fast data transfer
Pass/Fail Testing quickly identify
failing devices and when failures occur
Large Internal Storage save 20
waveforms and 20 setups to the internal
WaveAce memory
Waveform Sequence Recorder – record
and play back up to 2,500 waveforms
For more information, please contact:
WaveAce 1000 and 2000 Oscilloscopes Fact Sheet
Key Specifications
Bandwidth 40 MHz, 60 MHz, 70 MHz, 100 MHz, 200 MHz, 300 MHz
Channels 2 or 4
Memory up to 1 Mpts/Ch (2 Mpts interleaved)
Sample Rate up to 2 GS/s
Display 7” Bright Color Wide Display
Connectivity USB Host, USB Device, LAN
LeCroy
WaveAce 1000 and 2000 Oscilloscopes Fact Sheet
Ordering Information
Model Bandwidth Channel Memory Sample Rate
(per Ch / interleaved) (per Ch / interleaved)
WaveAce 1001 40 MHz 2 1 Mpts / 2 Mpts 500 MS/s / 1 GS/s
WaveAce 1002 60 MHz 2 1 Mpts / 2 Mpts 500 MS/s / 1 GS/s
WaveAce 1012 100 MHz 2 1 Mpts / 2 Mpts 500 MS/s / 1 GS/s
WaveAce 2002 70 MHz 2 12 kpts / 24 kpts 1 GS/s / 2 GS/s
WaveAce 2004 70 MHz 4 12 kpts / 24 kpts 1 GS/s / 2 GS/s
WaveAce 2012 100 MHz 2 12 kpts / 24 kpts 1 GS/s / 2 GS/s
WaveAce 2014 100 MHz 4 12 kpts / 24 kpts 1 GS/s / 2 GS/s
WaveAce 2022 200 MHz 2 12 kpts / 24 kpts 1 GS/s / 2 GS/s
WaveAce 2024 200 MHz 4 12 kpts / 24 kpts 1 GS/s / 2 GS/s
WaveAce 2032 300 MHz 2 12 kpts / 24 kpts 1 GS/s / 2 GS/s
WaveAce 2034 300 MHz 4 12 kpts / 24 kpts 1 GS/s / 2 GS/s
Standard Configuration
One passive probe per channel – 10x/1x Switchable
Getting Started Manual
USB Cable for use with WaveStudio
Calibration and Performance
Verification Certificate
3-year Warranty
Multi-language User Interface
Power Cord
Recommended Probes
Differential
AP031 700 V, 15 MHz High-Voltage Differential
Probe (÷10, ÷100)
High-Voltage
PPE1.2KV 10:1/100:1 200/300 MHz 50 MΩ High-Voltage
Probe 600 V/1.2 kV Max. Volt. DC
PPE2KV 100:1 400 MHz 50 MΩ 2 kV High-Voltage Probe
PPE4KV 100:1 400 MHz 50 MΩ 4 kV High-Voltage Probe
PPE5KV 1000:1 400 MHz 50 MΩ 5 kV High-Voltage Probe
PPE6KV 1000:1 400 MHz 50 MΩ 6 kV High-Voltage Probe
PPE20KV 1000:1 100 MHz 50 MΩ High-Voltage Probe 20 kV
Max. Volt. DC + 40 kVPeak AC
Pass/Fail mask testing can quickly
identify problems.
Capture and replay a sequence of up
to 2,500 waveforms to isolate that runt
or glitch which is causing problems in
your system.
32 parameters for making vertical,
horizontal and delay measurements.
Excellent Performance
40, 60, 70, 100, 200 and 300 MHz bandwidths
2 GS/s maximum sample rate
Up to 1 Mpts/Ch memory, 2 Mpts interleaved
Great Connectivity
USB host port for mass storage
USB device port for printing and PC control
LAN port on all WaveAce 2000 oscilloscopes
Smart Capabilities
Averaging, Peak Detect and Equivalent Time
Advanced Triggering
Digital Filtering
Built-in Help
Multi-Language User Interface
WaveAce1K2K-Fact-Sheet-21may12
PDF