IC Photocoupler Overview Slide 14

A programmable logic controller block diagram example is shown on this slide. By using a TLP2095 or TLP2098 with ± input type for I/O module (input side) it is possible to eliminate rectifiers such as bridge diodes, which are typically used in the input side of the circuit.