SY10/100E193 Datasheet by Microchip Technology

View All Related Products | Download PDF Datasheet
—'| _'_|'_l EJJJfijj
1
SY10E193
SY100E193
Micrel, Inc.
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
Pin Function
B0–B7Check Bit Inputs
BPAR Check Bit Parity Input
EV/OD Even/Odd Parity Select
EN Parity Enable
HOLD Syndrome Hold Input
S-IN Syndrome Bit Input
SHIFT Syndrome Bit Shift
CLK Clock Input
P1–P5Parity Output
PGEN Parity Generate Output
PARERR/PARERR Parity Error Output
VCCO VCC to Output
Hamming code generation
Extended 100E VEE range of –4.2V to –5.5V
8-bit wide
Expandable for more width
Provides parity register
Fully compatible with industry standard 10KH,
100K ECL levels
Internal75K input pulldown resistors
Fully compatible with Motorola MC10E/100E193
Available in 28-pin PLCC package
FEATURES
The SY10/100E193 are error detection and correction
(EDAC) circuits designed for use in new, high- performance
ECL systems. The E193 generates hamming parity codes
on an 8-bit word as shown in the block diagram. The P5
output gives the parity of the whole word. PGEN provides
word parity after Odd/Even parity control and gating with
the BPAR input. PGEN also feeds into a 1-bit shiftable
register for use as part of a scan ring.
The combinatorial part of the device generates the same
code pattern as the Motorola MC10193.
Used in conjunction with 12-bit parity generators, such
as the E160, a SECDED (single error correction, double
error detection) error system can be designed for a multiple
of an 8-bit word.
DESCRIPTION
ERROR DETECTION/
CORRECTION CIRCUIT
PIN NAMES
SY10E193
SY100E193
Rev.: F Amendment: /0
Issue Date:
March 2006
HHHHHHH r x 7:::::::
2
SY10E193
SY100E193
Micrel, Inc.
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
PACKAGE/ORDERING INFORMATION
Ordering Information(1)
Package Operating Package Lead
Part Number Type Range Marking Finish
SY10E193JC J28-1 Commercial SY10E193JC Sn-Pb
SY10E193JCTR(2) J28-1 Commercial SY10E193JC Sn-Pb
SY100E193JC J28-1 Commercial SY100E193JC Sn-Pb
SY100E193JCTR(2) J28-1 Commercial SY100E193JC Sn-Pb
SY10E193JZ(3) J28-1 Commercial SY10E193JZ with Matte-Sn
Pb-Free bar-line indicator
SY10E193JZTR(2, 3) J28-1 Commercial SY10E193JZ with Matte-Sn
Pb-Free bar-line indicator
SY100E193JZ(3) J28-1 Commercial SY100E193JZ with Matte-Sn
Pb-Free bar-line indicator
SY100E193JZTR(2, 3) J28-1 Commercial SY100E193JZ with Matte-Sn
Pb-Free bar-line indicator
Notes:
1. Contact factory for die availability. Dice are guaranteed at TA = 25°C, DC Electricals only.
2. Tape and Reel.
3. Pb-Free package is recommended for new designs.
28-Pin PLCC (J28-1)
TOP VIEW
PLCC
J28-1
26
27
28
1
2
3
4
18
17
16
15
14
13
12
25 24 23 22 21 20 19
5 6 7 8 9 10 11
B
5
B
4
P
2
V
CCO
B
6
B
7
P
1
V
CC
PARERR
P
3
P
5
PARERR
V
CCO
P
4
V
EE
B
3
BPAR
B
2
B
1
B
0
EV/OD
S-IN
EN
V
CCO
SHIFT
CLK
PGEN
HOLD
3
SY10E193
SY100E193
Micrel, Inc.
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
BLOCK DIAGRAM
3
B INPUTS
0
1
CLK
SHIFT
S-IN
BPAR
EV/OD
EN
HOLD
P
2
P
1
P
3
P
4
P
5
PGEN
PARERR
PARERR
BYTE (B0 B7)
B1, B2, B4, B7
B4, B5, B6, B7
B1, B3, B5, B7
B2, B3, B6, B7
6574210
0
1
D
4
SY10E193
SY100E193
Micrel, Inc.
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
DC ELECTRICAL CHARACTERISTICS
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°CTA = +25°CTA = +85°C
Symbol Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition
IIH Input HIGH Current ——150 ——150 ——150 µA
IEE Power Supply Current mA
10E 112 134 112 134 112 134
100E 112 134 112 134 129 155
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = 0°CTA = +25°CTA = +85°C
Symbol Parameter Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit Condition
tPD Propagation Delay to Output ps
B to P1, P2, P3, P4350 700 1000 350 700 1000 350 700 1000
B to P5 400 775 1150 400 775 1150 400 775 1150
EV/OD, BPAR to PGEN 350 650 850 350 650 850 350 650 850
B to PGEN 600 1000 1450 600 1000 1450 600 1000 1450
CLK to PARERR 300 550 850 300 550 850 300 550 850
tSSet-up Time ps
SHIFT 400 150 400 150 400 150
S-IN 300 50 300 50 300 50
HOLD 750 350 750 350 750 350
EN 500 250 500 250 500 250
EV/OD 1300 850 1300 850 1300 850
BPAR 1300 850 1300 850 1300 850
B 1700 1100 1700 1100 1700 1100
tHHold Time ps
SHIFT 200 150 200 150 200 150
S-IN 300 50 300 50 300 50
HOLD 100 350 100 350 100 350
EN 100 250 100 250 100 250
EV/OD 200 850 —–200 850 —–200 850
BPAR 200 850 —–200 850 —–200 850
B300 1100 —–300 1100 —–300 1100
trRise/Fall Time 300 700 1100 300 700 1100 300 700 1100 ps
tf20% to 80%
w .m mr .m HUUJ‘J‘J LLHLHJJ m m m, m w \w m , x H” w m «M w, r. a . (Wu + w v an mm .H
5
SY10E193
SY100E193
Micrel, Inc.
M9999-032006
hbwhelp@micrel.com or (408) 955-1690
28-PIN PLCC (J28-1)
Rev. 03
MICREL, INC. 2180 FORTUNE DRIVE SAN JOSE, CA 95131 USA
TEL + 1 (408) 944-0800 FAX + 1 (408) 474-1000 WEB http://www.micrel.com
The information furnished by Micrel in this data sheet is believed to be accurate and reliable. However, no responsibility is assumed by Micrel for its use.
Micrel reserves the right to change circuitry and specifications at any time without notification to the customer.
Micrel Products are not designed or authorized for use as components in life support appliances, devices or systems where malfunction of a product can
reasonably be expected to result in personal injury. Life support devices or systems are devices or systems that (a) are intended for surgical implant into
the body or (b) support or sustain life, and whose failure to perform can be reasonably expected to result in a significant injury to the user. A Purchasers
use or sale of Micrel Products for use in life support appliances, devices or systems is at Purchasers own risk and Purchaser agrees to fully indemnify
Micrel for any damages resulting from such use or sale.
© 2006 Micrel, Incorporated.

Products related to this Datasheet

IC PARITY GENERATOR 8-BIT 28PLCC
IC PARITY GENERATOR 8-BIT 28PLCC
IC PARITY GENERATOR 8-BIT 28PLCC
IC PARITY GENERATOR 8-BIT 28PLCC
IC PARITY GENERATOR 8-BIT 28PLCC
IC PARITY GENERATOR 8-BIT 28PLCC