E3C-LDA Datasheet by Omron Automation and Safety

View All Related Products | Download PDF Datasheet
CSM_E3C-LDA_DS_E_4_2
1
Photoelectric Sensor with Separate Digital Amplifier (Laser-type)
E3C-LDA
Variable Laser Beam for Spot, Line,
or Area Detection
• Long-distance detection (diffuse reflective: 1 m, retro-reflective:
7 m).
Beam shape selectable from spot, line, and area types to
match various applications.
Adjustable spot diameter.
Adjustable optical axis.
The E3DC-LDA0, which supports the EtherCAT Sensor
Communications Unit and the CompoNet Sensor
Communications Unit, is also included in product lineup.
Refer to Safety Precautions on page 9.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Features
Easy Sensor Installation and Sensing Characteristics
Equivalent to Through-beam Sensors.
Optical Axis Adjustment Mechanism
Variable Focal Point Mechanism
Spot Type
E3C-LR11
E39-R13
Coaxial Retroreflective
Model
The coaxial optical system and laser beam allow high-precision detection.
The built-in MSR Function inhibits the effect of reflected light from the workpiece.
Coaxial Optical System
Sensing
distance of
7 m.
Sensing
distance of
1 m.
At 1 m: Minimum spot diameter of 0.8 mm
Optical axis alignment range:
Approximately ±1 to1.5°
Spot, Line, and Area Types
All three beam types provide ample long-distance
detection of 1,000 mm.
Three beam types means a wider variety of applications.
Spot, Line, and Area T
ypes
Suitable for various applications without any additional costs.
Diffuse Reflective
Model
Spot Type
E3C-LD11
At 1,000 mm: Minimum spot diameter of 950 µm
Optical Axis Adjustment Mechanism
Variable Focal Point Mechanism
Mount Beam Units to a Spot Type Sensor to
convert to Line or Area Type.
Line Type
E3C-LD21
Area Type
E3C-LD31
At distance of 150 mm
7 mm - 28.5 mm - 33 mm
(VR minimum) (VR median) (VR maximum)
8 mm - 0.2 mm - 3.5 mm
(VR minimum) (VR median) (VR maximum)
At distance of 150 mm
5 to 33 mm
(VR minimum)(VR maximum)
5 to 15 mm
(VR minimum) (VR maximum)
Optical axis alignment range:
Approximately ±2°
The sensor detection point can be easily changed.
Spot diameter can be adjusted to
enable ultra-high-precision
positioning.
[Remote sening] [Counter] [Dilferenum aperauonl [Area output] [Selfidlagnosus] pwqerennal operananj 'ATC (Active Threshold Conlrol) V [Analog output) mpul mode‘s mode‘s \\ “9 lunmion [fiemme sening] [Counter] [Dilferenha‘ Operation: [Area 0mm] [Selfidlagnosus] pwqerennal operananj ATC (Active Threshold Cantrol) \ \ [Aime 0mm] (Sielfrdlagnosnfl ’D—Merenlial operalian‘ % omRon
E3C-LDA
2
Ordering Information
Sensor Heads (Dimensions page 12, 13)
* Select a Reflector (order separately) according to the application.
Amplifier Units
Pre-wired Amplifier Units (Dimensions page 14)
Amplifier Units with Wire-saving Connectors (A Wire-saving Connector (sold separately) is required.) (Dimensions page 15, 16)
* These models allow you to use an E3X-DRT21-S VER.3 Sensor Communications Unit. When using the E3X-DRT21-S VER.3, use an E3X-CN02 Connector without
a Cable for the Wire-saving Connector.
Amplifier Unit with Connector for Sensor Communications Unit (for EtherCAT and CompoNet) (Dimensions page 16)
Accessories (Order Separately)
Wire-saving connectors (Required for models for Wire-saving Connectors.)
*Protective stickers: provided. (Dimensions
E3X-DA-S/MDA)
Sensing method Appearance Beam shape Model Remarks
Diffuse-reflective
Spot
(variable) E3C-LD11 2M Mounting a Beam Unit (sold separately) allows
the use of line and area beams.
Line
(variable) E3C-LD21 2M
This model number is for the set consisting of the
E39-P11 mounted to the E3C-LD11.
Area
(variable) E3C-LD31 2M
This model number is for the set consisting of the
E39-P21 mounted to the E3C-LD11.
Coaxial
Retro-reflective
Spot
(variable) E3C-LR11* 2M Mounting a Beam Unit (order separately)
enables the use of line and area beams.
Spot (2.0-mm
fixed dia.)
E3C-LR12* 2M ---
Item Appearance Functions Model
NPN output PNP output
Advanced
models
External-
input models
E3C-LDA21 2M E3C-LDA51 2M
Twin-output
models
E3C-LDA11 2M E3C-LDA41 2M
ATC
function E3C-LDA11AT 2M E3C-LDA41AT 2M
Analog
output E3C-LDA11AN 2M E3C-LDA41AN 2M
Item Appearance Functions Model
NPN output PNP output
Advanced
models
External-
input models
E3C-LDA7 *E3C-LDA9 *
Twin-output
models
E3C-LDA6 *E3C-LDA8 *
ATC
function E3C-LDA6AT E3C-LDA8AT
Item Appearance Functions Model
Applicable Sensor
Commuincations Unit
Advanced
models
Twin-output
models
E3C-LDA0
E3X-ECT
E3X-CRT
Item Appearance Cable length No. of conductors Model
Master
Connector
2 m
4E3X-CN21
Slave
Connector 2E3X-CN22
Remote setting Counter Differential operation
Area output Self-diagnosis Differential operation
ATC (Active Threshold Control)
Analog output
Remote setting Counter Differential operation
Area output Self-diagnosis Differential operation
ATC (Active Threshold Control)
Area output Self-diagnosis Differential operation
Ordering Precaution for Amplifier Units with Wire-saving Connectors
Amplifier Units and Connectors are sold separately. Refer to the following tables when placing an order.
When Using 5 Amplifier Units
Amplifier Unit Applicable Connector (order separately)
Model NPN output PNP output Master Connector Slave Connector
Advanced
models
E3C-LDA6 E3C-LDA8
+E3X-CN21 E3X-CN22E3C-LDA7 E3C-LDA9
E3C-LDA6AT E3C-LDA8AT
5 Amplifier Units +
1 Master Connector
4 Slave Connectors
mm
E3C-LDA
3
Mobile Console (Dimensions E3X-DA-S/MDA)
Note: Use the E3X-MC11-S Mobile Console for the E3X-LDA Series Amplifier Units.
The E3X-MC11-SV2 is an upgraded version of the E3X-MC11-S that is fully
interchangeable with the older model. Refer to E3X-DA-S/MDA for details.
Beam Unit (for E3C-LD11/LR11)
A Beam Unit is not provided with the Sensor and must be
ordered separately as required.
Mounting Bracket
A Mounting Bracket is not provided with the Amplifier Unit and must be
ordered separately as required.
(Dimensions E39-L/E39-S/E39-R)
End Plate
A End Plate is not provided with the Amplifier Unit and must be ordered
separately as required.
(Dimensions PFP-@)
Reflectors (Required when using retro-reflective models)
A Reflector is not provided with the Sensor head. Be sure to
order a Reflector separately.
(Dimensions E39-L/E39-S/E39-R)
Note:
For details, refer to
Reflectors
E39-L/E39-S/E39-R
* Use a standard model (E39-R12/R13) if the distance from the Sensor is 400
mm or more. Use the short-distance model (E39-R14) if the distance is less
than 400 mm.
Appearance Model Remarks
E3X-MC11-SV2
(model number of set)
Mobile Console with Head,
Cable, and AC adapter
provided as accessories
E3X-MC11-C1-SV2 Mobile Console
E3X-MC11-H1 Head
E39-Z12-1 Cable (1.5 m)
Applicable
Sensor Head Appearance Beam
shape Model
E3C-LD11
Line E39-P11
Area E39-P21
E3C-LR11
Line E39-P31
Area E39-P41
Appearance Model Quantity
E39-L143 1
Appearance Model Quantity
PFP-M 1
Type Appearance Model
Standard
Effective area: 23 × 23 mm *E39-R12
Standard
Effective area: 7 × 7 mm *E39-R13
Transparent object detection
Effective area: 23 × 23 mm *E39-R14
Sheet (cuttable)
Effective area: 195 × 22 mm E39-RS4
Sheet (cuttable)
Effective area: 108 × 46 mm E39-RS5
I
E3C-LDA
4
Ratings and Specifications For dimensions, refer to pages 12 to 16.
Sensor Heads
*1. Sensing distance values are for white paper.
*2. These sensing distance values apply when a E39-R12 Reflector is used. The MSR function is built-in. The reflected light from the object being measured may affect
the sensing accuracy, so adjust the threshold value before use.
*3. The beam radius is the value for the middle measurement distance and indicates a typical value for the middle sensing distance. The radius is defined by light
intensity of 1/e2 (13.5%) of the central light intensity.
Light will extend beyond the main beam and may be affected by conditions surrounding the object being measured.
*4. The E3C-LR12 has a fixed beam size (the focal point cannot be changed).
Type Diffuse-reflective Coaxial Retro-reflective (with M.S.R. function)
Item Model E3C-LD11 E3C-LD21 E3C-LD31 E3C-LR11
E3C-LR11+
E39-P31
E3C-LR11+
E39-P41 E3C-LR12
Light source
(wavelength)
Red semiconductor laser diode (650 nm), 3 mW max.
(JIS Class 2, IEC/EN Class 2, and FDA Class 2)
Red semiconductor laser diode (650 nm), 3 mW max.
(JIS Class 2, IEC/EN Class 2, and FDA Class 2)
1 mW max.
(JIS Class 1,
IEC/EN Class 1,
and FDA Class 2)
Sensing
distance
High-resolution mode: 30 to 1,000 mm
Standard mode: 30 to 700 mm
Super-high-speed mode: 30 to 250 mm *1
7 m
5 m
2 m *2
1,700 mm
1,300 mm
700 mm *2
900 mm
700 mm
400 mm *2
7 m
5 m
2 m *2
Focus *3
0.8 mm max.
(at distances up
to 300 mm)
33 mm
(at 150 mm)
33 × 15 mm
(at 150 mm)
0.8 mm max.
(at distances up
to 1,000 mm)
28 mm
(at 150 mm)
28 × 16 mm
(at 150 mm)
2.0-mm dia.
(at distance up
to 1,000 mm)
Functions Variable focal point mechanism (focus adjustment) *4, optical axis adjustment mechanism (axis adjustment)
Indicators LDON indicator: Green; Operation indicator: Orange
Ambient
illumination
(Receiver side)
Incandescent lamp: 3,000 lx
Ambient
temperature Operating: 10 to 55°C, Storage: 25 to 70°C (with no icing or condensation)
Ambient
humidity Operating/storage: 35% to 85% (with no condensation)
Insulation
resistance 20 MΩ min. at 500 VDC
Dielectric
strength 1,000 VAC at 50/60 Hz for 1 minute
Shock
resistance Destruction: 300 m/s2 6 directions 3 times each (up/down, right/left, forward/backward)
Vibration
resistance Destruction: 10 to 150 Hz with double amplitude of 0.7 mm, in X, Y, and Z directions for 80 min each
Degree of
protection IP40 (IEC) IP40 (IEC 60529)
Connection
method Connector (standard cable length: 2 m)
Materials Case and cover: ABS
Front surface filter: Methacrylic resin
Case and cover: ABS
Front surface filter: Glass
Weight
(packed state)
Approx. 85 g Approx. 100 g
Accessories Instruction manual, Laser warning labels (English)
I
E3C-LDA
5
Amplifier Units
*1. This model allows you to use an E3X-ECT EtherCAT Sensor Communications Unit or E3X-CRT CompoNet Sensor Communications Unit.
*2. Communications are disabled if super-high-speed mode is selected, and the mutual interference prevention function and the communications function for the
Mobile Console will not function.
*3. The following temperature ranges apply when an E3X-ECT EtherCAT or E3X-CRT CompoNet Sensor Communications Unit is used with the E3C-LDA0: Groups
of 1 or 2 Amplifier Units: 0 to 55°C, Groups of 3 to 10 Amplifier Units: 0 to 50°C, Groups of 11 to 16 Amplifier Units: 0 to 45°C, Groups of 17 to 30 Amplifier Units
(with the E3X-ECT): 0 to 40°C.
*4. The vibration resistance of the E3C-LDA0 is as follows: Destruction: 10 to 150 Hz with a 0.7-mm double amplitude for 80 min each in X, Y, and Z directions.
*5. The shock resistance of the E3C-LDA0 is as follows: Destruction: 150 m/s2, 3 times each in X, Y, and Z directions.
*6. A connector for a Sensor Communications Unit is used to connect the E3C-LDA0.
Type External-input models Twin-output models ATC-output models Analog-output
models
Standard models Standard models
Model for Sensor
Communications
Unit
Standard models
Standard models
Pre-wired Wire-saving
connector Pre-wired Wire-saving
connector Pre-wired Wire-saving
connector Pre-wired
Model
NPN output
E3C-LDA21 E3C-LDA7 E3C-LDA11 E3C-LDA6 E3C-LDA0 *1E3C-LDA11AT E3C-LDA6AT E3C-LDA11AN
Item
PNP output
E3C-LDA51 E3C-LDA9 E3C-LDA41 E3C-LDA8 E3C-LDA41AT E3C-LDA8AT E3C-LDA41AN
Supply voltage 12 to 24 VDC ±10%, ripple (p-p) 10% max.
Power consumption 1,080 mW max. (current consumption: 45 mA max. at power supply voltage of 24 VDC)
Control output
ON/OFF output Load power supply voltage: 26.4 VDC max.; NPN/PNP (depends on model) open collector
Load current: 50 mA max.; residual voltage: 1 V max.
Analog output ---
Control output
Voltage output: 1
to 5 VDC
(connected load
10 k
Ω
min.)
Temperature
characteristics
0.3% F.S./
°
C
Response time/
Repeat
accuracy
Super-high-
speed mode:
100
μ
s/4.0%
F.S.
High-speed
mode: 250
μ
s/
4.0% F.S.
Standard mode:
1 ms/2.0% F.S.
High-resolution
mode: 4 ms/
2.0% F.S.
Response time
Super-highspeed
mode *280 μs for operation and reset 100 μs for operation and reset --- 100 μs for operation and reset
High-speed mode
250 μs for operation and reset
Standard mode 1 ms for operation and reset
High-resolution
mode 4 ms for operation and reset
Functions
Differential
detection
Switchable between single edge and double edge detection mode.
Single edge: Can be set to 250 μs, 500 μs, 1 ms, 10 ms, or 100 ms.
Double edge: Can be set to 500 μs, 1 ms, 2 ms, 20 ms, or 200 ms.
---
Timer function
Select from OFF-delay, ON-delay, or one-shot timer.
1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms increments, and 1 to
5 s set in 1-s increments)
Zero-reset Negative values can be displayed.
Initial reset Settings can be returned to defaults as required.
Mutual interference
prevention
Possible for up to 10 Units. *2
Counter
Switchable between up counter
and down counter.
Set count: 0 to 9,999,999
---
I/O settings
External input setting (Select from
teaching, power tuning, zero reset, light
OFF, or counter reset.)
Output setting (Select from channel 2 output, area
output, or self-diagnosis.)
Output setting (Select from channel 2
output, area output, self-diagnosis, or
ATC error output.)
Analog output setting
(Offset voltage can be
adjusted.)
Digital display Select from digital incident level + threshold or six other patterns.
Display orientation Switching between normal/reversed display is possible.
Ambient temperature
range *3
Operating: Groups of 1 to 2 Amplifiers:
25
°
C to 55
°
C, Groups of 3 to 10 Amplifiers:
25
°
C to 50
°
C, Groups of 11 to 16 Amplifiers:
25
°
C to 45
°
C
Storage: 30°C to 70°C (with no icing)
Ambient humidity range
Operating and storage: 35% to 85% (with no condensation)
Insulation resistance 20 MΩ at 500 VDC
Dielectric strength 1,000 VAC at 50/60 Hz for 1 min.
Vibration resistance *4Destruction: 10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions
Shock resistance *5Destruction: 500 m/s2, 3 times each in X, Y, and Z directions
Degree of protection IP50 (IEC 60529)
Connection method Pre-wired or wire-saving connector *6
Weight
(packed state)
Pre-wired Models: Approx. 100 g
Wire-saving Connector Models: Approx. 55 g
Sensor Communications Unit Connector Models: Approx. 55 g
Materials Case Polybutylene terephthalate (PBT)
Cover Polycarbonate
omRon
E3C-LDA
6
Engineering Data (Reference Value)
Minimum Beam Diameter vs. Sensing Distance
E3C-LD11 E3C-LR11 E3C-LR12
Beam Shape vs. Sensing Distance
E3C-LD21 E3C-LD31
Differential Travel vs. Sensing Distance
E3C-LD
1000
900
800
700
600
500
400
300
200
100
0
100 300200 500400 600
900
700 800
1000
Distance (mm)
Beam diameter (μm)
1325467
Distance (m)
6
5
4
3
2
1
0
Y direction
X direction
X direction
Y direction
Beam diameter (mm)
1325467
Distance (m)
5
4
3
2
1
0
Beam diameter (mm)
Y direction
X direction
220
200
180
160
140
120
100
80
60
40
20
0
FOCUS control turned
all the way to right
FOCUS control turned
to center
FOCUS control turned
all the way to left
100 300200 500400 600
900
700 800
1000
Distance (mm)
X direction
Y direction
X direction
Y direction
X direction
Y direction
(1)
(2)
(3)
(4)
(5)
(6)
(1)
(3)
(6)
(5)
(2) (4)
Beam shape X/Y (mm)
Y direction
X direction
200
180
160
140
120
100
80
60
40
20
0100 300200 500400 600
900
700 800
1000
Distance (mm)
Beam shape X/Y (mm)
FOCUS control turned
all the way to right
FOCUS control turned
all the way to left
X direction
Y direction
X direction
Y direction
(1)
(2)
(3)
(4)
(1)
(2)
(3)
(4)
Note: The dashed lines indicate non-
visible regions of the beam shape.
50
45
40
35
30
25
20
15
10
5
0
Super-high-speed mode
Standard mode
High-resolution mode
200 400 600 800 1000
Distance (mm)
Detected object: white paper
ON OFF
Distance
Differential
travel
Differential travel (mm)
i i >1 1 4" 7 ,1 I! % 7 7 { I! ,E __T (DARK ON) 1 omRon
E3C-LDA
7
I/O Circuit Diagrams
NPN Output
Model
Operation
mode
Timing charts
Mode selector
switch
Output circuit
E3C-LDA11
E3C-LDA6
E3C-LDA11AT
E3C-LDA6AT
Light-ON L-ON
(LIGHT ON)
Dark-ON D-ON
(DARK ON)
E3C-LDA21
E3C-LDA7
Light-ON L-ON
(LIGHT ON)
Dark-ON D-ON
(DARK ON)
E3C-LDA11AN
Light-ON L-ON
(LIGHT ON)
Dark-ON D-ON
(DARK ON)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
Indicator
(orange)
(Between brown and black leads)
Output
transistor
Load
(e.g., relay)
ch1/
ch2
Photo-
electric
Sensor
Main
Circuit
Load
Load
Operation indicator
(orange) ch2 Brown
Black
Control output
1
Control output 2
Orange
Blue
12 to
24 VDC
Operation indicator
(orange)
ch1
Display
Incident light
No incident ligh
t
ON
OFF
ON
OFF
Operate
Reset
Operation
Indicator
(orange)
(Between brown and black leads)
Output
transistor
Load
(e.g., relay)
ch1/
ch2
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Rese
t
Operation
Indicator
(orange)
(Between brown and black leads)
Output
transistor
Load
(e.g., relay)
Brown
Control output
External
input
Black
Orange
Blue
12 to
24 VDC
Load
Photo-
electric
Sensor
Main
Circuit
Operation indicator (orange)
Display
Power
tuning
indicator
(orange)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
Indicator
(orange)
(Between brown and black leads)
Output
transistor
Load
(e.g., relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
Indicator
(orange)
Output
transistor
Load
(e.g., relay)
(Between brown and black leads)
Brown
Control output
Analog
output
Black
Orange
Blue
12 to
24 VDC
Load
Load
Photo-
electric
Sensor
Main
Circuit
Operation indicator (orange)
Display
Power
tuning
indicator
(orange)
10 kΩ min.
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
Indicator
(orange)
Output
transistor
Load
(e.g., relay)
(Between brown and black leads)
l—m"—, """ 7 1% {514 3 fl I . o: DrON (DARKOND |_..—__—__ LVDN (LIGHT ON) NE #W NE #W NE #W DrON I
E3C-LDA
8
PNP Output
Model
Operation
mode
Timing charts
Mode selector
switch
Output circuit
E3C-LDA41
E3C-LDA8
E3C-LDA41AT
E3C-LDA8AT
Light-ON L-ON
(LIGHT ON)
Dark-ON D-ON
(DARK ON)
E3C-LDA51
E3C-LDA9
Light-ON L-ON
(LIGHT ON)
Dark-ON D-ON
(DARK ON)
E3C-LDA41AN
Light-ON L-ON
(LIGHT ON)
Dark-ON D-ON
(DARK ON)
Incident light
No incident lig
ht
ON
OFF
ON
OFF
Operate
Reset
Operation
Indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(e.g., relay)
ch1/
ch2
Photo-
electric
Sensor
Main
Circuit Load
Load
Operation indicator (orange) ch2
Control
output 2
Control
output 1
Brown
Black
Orange
Blue
12 to
24 VDC
Operation indicator
(orange)
ch1
Display
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
Indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(e.g., relay)
ch1/
ch2
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
Indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(e.g., relay)
Load
Brown
External
input
Orange
Black
Blue
12 to
24 VDC
Control
output
Photo-
electric
Sensor
Main
Circuit
Operation indicator (orange)
Display
Power
tuning
indicator
(orange)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
Indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(e.g., relay)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
Indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(e.g., relay)
Load Load
Brown
Orange
Black
Blue
12 to
24 VDC
Control
output
Analog
output
10 kΩ min.
Photo-
electric
Sensor
Main
Circuit
Operation indicator (orange)
Display
Power
tuning
indicator
(orange)
Incident light
No incident light
ON
OFF
ON
OFF
Operate
Reset
Operation
Indicator
(orange)
(Between blue and black leads)
Output
transistor
Load
(e.g., relay)
@©@ gm >® I
E3C-LDA
9
Nomenclature
Amplifier Units
Twin Output Models
(E3C-LDA11/LDA41/LDA6/LDA8/LDA0)
External Input Models
(E3C-LDA21/LDA51/LDA7/LDA9)
Safety Precautions
Refer to the Photoelectric Sensors Technical Guide.
This product is not designed or rated for ensuring
safety of persons either directly or indirectly. Do not
use it for such purpose.
Never look into the laser beam.
Doing so continuously will result in visual
impairment.
The following rules are required to ensure safety. Be sure to observe
these rules.
1. Installation environment
Do not use in an environment where combustible or explosive gas
is present.
To ensure safe operation and maintenance of the product, install
it away from high-voltage devices and power devices.
2. Power supply and wiring
Do not exceed the rated voltage (12 to 24 VDC ±10%).
Do not remove a connector while it is supplying power. This may
damage the product.
3. Other points
Do not attempt to disassemble, repair, or modify the product.
When disposing of the product, treat it as industrial waste.
Incident level, function, etc. Threshold, function settings, etc. Function setting operations
UP
DOWN
MODE
Use to switch between the display
and setting channels.
Use to select SET or RUN mode.
ON when output is ON.
OFF when output is OFF.
ON when output is ON.
OFF when output is OFF.
Operation indicator
for channel 1 (orange)
Main Display (red)
Sub-Display (green) Operation Keys
Channel Selector
Mode Selector
Operation indicator
for channel 2 (orange)
Incident level, function, etc. Threshold, function settings, etc. Function setting operations
UP
DOWN
MODE
Use to switch between Light
ON and Dark ON modes.
Use to select SET or RUN mode
ON: Power tuning is set.
ON when output is ON.
OFF when output is OFF.
Operation Indicator
(orange)
Main Display (red)
Sub-Display (green) Operation Keys
Operation Mode Selector
Mode Selector
Power Tuning Indicator
WARNING Precautions for Safe Use
E3C-LDA
10
Do not use the product in atmospheres or environments that exceed
product ratings.
Official laser safety measures have been established regarding laser
devices both inside and outside of Japan. For details, refer to Laser
Beam Safety Standards.
Amplifier Units
Designing
Operation after Turning Power ON
The Amplifier Unit is ready to operate within 200 ms after the power
supply is turned ON. If the Sensor and load are connected to power
supplies separately, be sure to turn ON the power supply to the
Sensor first.
Cleaning
Do not use thinner, benzene, acetone, or kerosene. If the filter on the
front of the sensor becomes soiled with dust, oil droplets, or other
materials,
(a) Use a blower brush (used to clean camera lenses) to blow large
dust particles from the surface. Do not blow the dust away with
your mouth.
(b) Use a soft cloth (for cleaning lenses) with a little alcohol to remove
the remaining dust.
Note: Do not use a scrubbing action when cleaning as a scratch on
the filter could result in the Sensor malfunctioning.
About the object
Measurement may not be possible or may not be precise with some
types of object materials and shapes (such as transparent objects,
objects with extremely low reflectance, objects smaller than the beam
diameter, objects with a large curvature, highly tilted objects, etc).
Mounting
Mounting and removing the sensor head
1. Open the protective cover.
2. With the locking lever on the sensor head connector facing up,
insert the connector into the connector opening.
To remove the connector, press down on the locking lever and pull the
connector out.
Connecting and Disconnecting Connectors
(Mounting Connectors)
1. Insert the Master or Slave Connector into the Amplifier Unit until it
clicks into place.
2. Attach the protector seals (provided as accessories) to the sides
of master and slave connectors that are not connected.
Note: Attach the seals to the sides with grooves.
(Removing Connectors)
1. Slide the slave Amplifier Unit(s) for which the Connector is to be
removed away from the rest of the group.
2. After the Amplifier Unit(s) has been separated, press down on the
lever on the Connector and remove it. (Do not attempt to remove
Connectors without separating them from other Amplifier Units
first.)
Precautions for Correct Use
1
2
Lock lever
Insert
Protective seal
Power supply
terminal for linking
Remove
Lever
Press down
omRon
E3C-LDA
11
Mounting and Removing Amplifier Units
(Mounting Amplifier Units)
1. Mount the Amplifier Units one at a time onto the DIN track.
2. Slide the Amplifier Units together, line up the clips, and press the
Amplifier Units together until they click into place.
(Separating Amplifier Units)
Slide Amplifier Units away from each other, and remove from the DIN
track one at a time. (Do not attempt to remove Amplifier Units from the
DIN track without separating them first.)
Mounting the End Plate (PFP-M)
An End Plate should be used if there is a possibility of the Amplifier
Unit moving, e.g., due to vibration. If a Mobile Console is going to be
mounted, connect the End Plate in the direction shown in the following
diagram.
Mounting the Mobile Console Head
Leave a gap of at least 20 mm between the nearest Amplifier Unit and
the Mobile Console head.
Adjustments
Mutual Interference Protection Function
There may be some instability in the digital display values due to light
from other sensors. If this occurs, decrease the sensitivity (i.e., decrease
the power or increase the threshold) to perform stable detection.
Beam shape adjustment function
The shape of the beam at each sensing distance can be adjusted by
turning the beam shape control.
(E3C-LD11/-LR11)
Turn the control to the left to adjust the focal position to short distance
detection. Turn the control to the right to adjust the focal position to
long distance detection.
(E3C-LD21)
Turn the control to the left to decrease the beam width. Turn the
control to the right to increase the beam width.
(E3C-LD31)
Turn the control to the left to decrease the beam area. Turn the control
to the right to increase the beam area.
Do not turn the beam shape control to more than 60 mNm.
Otherwise, this may damage the unit.
Optical axis alignment function
The angle of beam projection can be adjusted by turning the optical
axis alignment control.
Turning the control about 45° to the right will move the optical axis to
the left by the number of degrees shown below.
Turning the control about 45° to the left will move the optical axis to
the right by the number of degrees shown below.
If the act of adjusting the optical axis changes the beam shape, adjust
the beam shape again. Turning the control 180° will return the optical
axis to its original position.
EEPROM Writing Error
If the data is not written to the EEPROM correctly due to a power
failure or static-electric noise, initialize the settings with the keys on
the Amplifier Unit. ERR/EEP will flash on the display when a writing
error has occurred.
Optical Communications
Several Amplifier Units can be slid together and used in groups. Do
not, however, slide the Amplifier Units or attempt to remove any of the
Amplifier Units during operation.
Other Precautions
Protective Cover
Always keep the protective cover in place when using the Amplifier
Unit.
Mobile Console
Use the E3X-MC11-C1-SV2 Mobile Console for the E3C-LDA-series
Amplifier Units.
Note: 1.
The specifications for ambient temperature will vary
according to the number of Amplifier Units used together. For
details, refer to
Ratings and Specifications
on page 5.
2. Always turn OFF the power supply before mounting or
separating Amplifier Units.
Sensor head connector catches
DIN track
1
2
DIN track
1
1
2
End Plate
20 mm
Do not turn the beam shape
control to more than 60 mN·m.
This may damage the unit.
E3C-LR11 : Approx. 1.5°
E3C-LR12 : Approx. 1.0°
E3C-LD@@ : Approx. 2.0°
Adjustment angle
(um: mm) E3C-LD11 - I V % Eac-LD21 Wm. Eeam unn Anached I17 ,% H * w I
E3C-LDA
12
Dimensions
Sensor Heads
(Unit: mm)
Tolerance class IT16 applies to dimensions in this data sheet unless otherwise specified.
6
3
18
6
3
5
18
8.4
3.7
4.75
3.6
9.7
15.8
1.7
Emitter
Receiver
6.6
3 dia.
12.1
FOCUS control
(Beam shape control)
6.6
12.8
13.2
12.7
18.5
2LD ON indicator
Operation indicator
AXIS control
(Optical axis alignment control)
2.7 dia. 2
18
1.8-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.15 mm2),
Standard length: 2 m
27
Connector
Two, R 2.6
3.1
18.8
25
20 5.1
27.7
33
R4.8
Two, 3.2-dia.
mounting holes
6
E3C-LD11
6.6
12.8
13.2
15.7
21.5
2
5.3
8
LD ON indicator
Operation indicator
AXIS control
(Optical axis alignment control)
2.7 dia.2
23 5.1
30.7
36
2
1
4.1
18.8
27
30
Two, R 2.6
R4.8
Two, 3.2-dia.
mounting holes
6
Connector
18 1.8-dia. vinyl-insulated round cable with 2 conductors
(Conductor cross section: 0.15 mm2),
Standard length: 2 m
6.6
3 dia.
13.1
6
3.6
Emitter
Receiver
710.9
19.5
3.9
9
15.8
2.1
6
FOCUS control
(Beam shape control)
With Beam Unit Attached
E3C-LD21
E3C-LD31
JIL omRon
E3C-LDA
13
2.7 dia. 2
6.6
R4.8
Two, 3.2-dia.
mounting holes
Two, R 2.6
4.4 (optical axis)
23.1 33
18.8
20.9
25
6
26
39
33.8
5.1
20
9
Emitter/
Receiver
7
8.8
2.2
3.1
15.8
6
6
18 1.8-dia. vinyl-insulated round cable with 2
conductors (Conductor cross section: 0.15 mm2),
Standard length: 2 m
LD ON indicator
Operation indicator
AXIS control
(Optical axis alignment control)
18.7
12.813.2
24.5 2
Connector
FOCUS control
(Beam shape control)
*The E3C-LR12 does
not have FOCUS control.
6.6
12.1
3 dia.
E3C-LR11/-LR12
I
E3C-LDA
14
Amplifier Units
Connector
Sub-display
Round ( ): Power tuning indicator
Oblong ( ): 2nd operation indicator
4-dia. vinyl-insulated round cable with 4
conductors (Conductor cross section: 0.2 mm2,
Insulation diameter: 1.1 mm),
Standard length: 2 m
36.7
Operation indicator
Main display
3.9 × 3
=11.7
3.9 × 3
=11.7
2.5
Two, M3
Connector
3.4
4.1
32
4.4
Mounting Bracket (E39-L143) (Order separately)
SUS304 stainless steel
Two, 3.2-dia.
mounting holes
13.8
10
24.7
18.15
21.1
35.8
38.8
76
9.9
34.1
12.5
3.4
16
16
34.1 16
34.8 Hole for optical communications
50.3
* The Mounting Bracket can also
be used on side A.
(A)*
Mounting Holes
With Mounting Bracket Attached
Pre-wired Amplifier Units
E3C-LDA11
E3C-LDA21
E3C-LDA41
E3C-LDA51
E3C-LDA11AT
E3C-LDA41AT
E3C-LDA11AN
E3C-LDA41AN
dflfl JD 0 IIEII fl Lvndwdmfi ~1de I $flw~wwii+fl33 I
E3C-LDA
15
Operation indicator
Connector
Main display
Sub-display
Round ( ): Power tuning indicator
Oblong ( ): 2nd operation indicator
36.7
3.9 × 3
=11.7
3.9 × 3
=11.7
2.5
Two, M3
3.4
4.1
32
(A)*
4.4
4 dia.
Hole for optical communications
Mounting Bracket (E39-L143) (Order separately)
SUS304 stainless steel
Mounting Holes
13.8
10
24.7
50.3
18.15
21.1
35.8
38.8
76
79.2
82.7
9.9
34.1
12.95
3.4
16
16
34.1 16
34.8
Connector
E3X-CN21
E3X-CN22
* The Mounting Bracket can
also be used on side A.
Connector
With Mounting Bracket Attached
Amplifier Units with Wire-saving Connectors
E3C-LDA6
E3C-LDA7
E3C-LDA8
E3C-LDA9
E3C-LDA6AT
E3C-LDA8AT
I
E3C-LDA
16
Accessories (Order Separately)
Reflectors
Refer to E39-S/E39-R for details.
Mounting Bracket
Refer to E39-L for details.
End Plate
Refer to DIN rail for details.
Wire-saving connector
Refer to E3X-DA-S/MDA for details.
Mobile Console
Refer to E3X-DA-S/MDA for details.
32
4 dia.
76
79.2
82.7
12.95
Connector
E3X-CN11
E3X-CN21
4
10
* Cable diameters are as follows:
E3X-CN12 2.6 dia.
E3X-CN22 4.0 dia.
32
A dia. *
76
79.2
82.7
4.8
12.95
3
Connector
E3X-CN12
E3X-CN22
4
10
17.45
11.55
3
Amplifier Units with Wire-saving Connectors
E3C-LDA6
E3C-LDA7
E3C-LDA8
E3C-LDA9
E3C-LDA6AT
E3C-LDA8AT
21.1
38.8
2.5
34.1 16
34.8
76
95
19
50.3
32
9.9
4.1
32
3.4
13.8
10
13.8
28.1 16
3.4
4.4
11.7
11.7
18.15
35.8
Two, 3.2 dia. holes
24.7
Amplifier Unit with Connector for Sensor Communications Unit
E3C-LDA0
Terms and Conditions Agreement Read and undersland Ihis catalog Warranlres See hugzl/www omron.com/g|obal/ erirarion on Liabilrry‘ Erc Surrabrlily of Use Programmable Products. Performanoe Dara. Change rn Sgecificarions. Errors and Omissrons. n o ass
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omrons exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyer’s application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the user’s programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omrons representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2015.9
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2015 All Right Reserved.

Products related to this Datasheet

BEAM UNIT HEAD FOR E3C-LD11
BEAM UNIT HEAD FOR E3C-LR11
BEAM UNIT HEAD FOR E3C-LR11
SENSOR REFLECTV 1M HEAD SPOT DIF
SENSOR REFLECTIVE 1M CH MOUNT
SENSOR REFLECTVE 1M HEAD DIFFUSE
AMP TWIN-OUTPT NPN-OUTPT W/CABLE
AMP ANALOG LASER TYPE NPN-OUTPUT
AMP ATC LASER TYPE NPN-OUTPUT
AMPLIF EXTERNL-INPUT NPN-OUTPUT
AMP TWIN-OUTPT PNP-OUTPT W/CABLE
AMP ANALOG LASER TYPE PNP-OUTPUT
AMP ATC LASER TYPE PNP-OUTPUT
AMPLIF EXTERNAL-INPUT PNP-OUTPUT
AMP TWIN-OUTPT NPN-OUTPUT W/CONN
AMP ATC LASER NPN-OUTPUT W/CONN
AMP EXTERNL-INPT NPN-OUTPT CONN
AMP TWIN-OUTPT PNP-OUTPT W/CONN
AMP ATC LASER PNP-OUTPUT W/CONN
AMP EXTRNL-INPT PNP-OUTPT W/CONN
SENSOR RETROREFLECTIVE 7M COAX
SENSOR RETROREFLECT 7M CH MOUNT
SENSOR RETROREFLECT 7M CH MOUNT
5M E3X-DA CABLE
PROGRAMMER FOR E3X-DAS/MDA
PROGRAMMER KIT FOR E3X-DAS/MDA