CXA-0326 Datasheet by TDK Corporation

View All Related Products | Download PDF Datasheet
DK-Lamlzia 5:3!“ mm BE! fl rm r A MED MEAsukE
■ Features
CXA-0326
CXA-0326 Specifications
Please refer to each specification before use
■ Applications
Dimming/Connector Type
2-output
Applicable panel size*: 5 to 8 inches
With brightness control function (Pulse Wide Modulation mode).
With a sensing function for running out of lamp (alarm output).
●In the high-voltage generator (a terminal and a pattern),
an anti-dust measure by silicone application is taken.
(Notice) Applicable panel size becomes a standard.
Electrical Characteristics
Other Specifications
Item Unit Symbol Speci cation Condition
min typ max Vin(V) Vrmt(V) Vbr(V) Rbr(kΩ ) Ta(℃ ) RL(kΩ ) Remark
Output Current mArms
Iout
(Maximum dimmer)
4.9 5.5 6.1 9 to 19 5 0 -
-10 to +70
68
Voltage dimmer (*1)
4.9 5.5 6.1 9 to 19 5 - 0
-10 to +70
68
Volume dimmer (*1)
Iout
(Minimum dimmer)
1.9 2.5 3.1 9 to 19 5 2.5 -
-10 to +70
68
Voltage dimmer (*1)
1.9 2.5 3.1 9 to 19 5 - 50
-10 to +70
68
Volume dimmer (*1)
Input Current A Iin1 - 0.75 9 to 19 5 0
-10 to +70
68
Remote ON
mA Iin2 - 2 9 to 19 0
-10 to +70
68
Remote OFF
Frequency kHz Freq1 49 55 61 9 to 19 5 0
-10 to +70
68
Hz
Freq2 (Duty frequency)
300 350 400 9 to 19 5 2.5 50
-10 to +70
68
Open Circuit Voltage
Vrms Vopen 1000 1300 - 9 to 19 5 0
-10 to +70
Open load
Alarm Signal V Vst 4.5 5.0 5.5 9 to 19 5 0
-10 to +70
In case of lamp anomaly (*2)
- 0 0.5 9 to 19 5 0
-10 to +70
68
On a normal operation (*2)
(*1) Please refer to the connection diagram for details of a dimming method.
(*2) Please refer to the connection diagram for details of alarm output.
Dimming Function
Yes
Operating Temperature
-10 to +70
Storage Temperature
-30 to +85
Operating Humidity Ratio
RH% 95Max
Safety Standard
Weight g 20
Dimensions(WxDxH)
mm 103x30x8 (*3)
Fused Input Yes
Remote ON OFF
Yes
Alarm Signal Function
Yes
Shutdown Function
No
Silicone Coating on
High Voltage Area
Yes
(*3) These dimensions are indicated the maximum only H. Others are typical
values.
This means that, in conformity with EU Directive
2002/95/EC, lead, cadmium, mercury, hexavalent
chromium, and specific bromine-based flame
retardants, PBB and PBDE, have not been used,
except for exempted applications.
Conformity to RoHs Directive
001-01/20080228/etl_cxa_0326
All specifications are subject to change without notice.
1
/ / 103:0.5 / (3 0) 9710.2 / / /, / m‘ ; '\ o ‘ +I $27“: a , NEWMAN _ I mm/ (3; (10) 8 Omax Lamlzia
Outline Drawing
CXA-0326
Example of label marking
Product name, Lot No., Country of origin, TDK-Lambda logotype
Silicone
     High-voltage generator ※
(The entire surface within a range of 55mm away from the end of the basein)
※From high-voltage generator, please secure space distance more than 2mm in top and bottom right and left.
Connector
Connector
number
Part number
Printed circuit board PCB
Input connector CN1
Output connector CN2,CN3
Model/Material
Composite(CEM-3)
53261-0871
SM02(8.0)B-BHS-1-TB(LF)(SN)
Quantity
1
1
2
Remarks
UL94V-0 t=1.0
Molex Inc.
JST Mfg. Co., Ltd.
Recommended applicable connector
51021-0800
BHR-03VS-1
Terminal Numbers And Functions
Input side CN1
Terminal
number Symbol Rated voltage Remarks
CN1-1
CN1-2
CN1-3
CN1-4
CN1-5
Vin
GND
Vrmt
9.0 to 19.0V
0V
0V/2.5V to Vin
0 to 2.5V/0 to 50kΩ
Remote terminal
Dimmer terminal1
0 to 0.4VOFF
2.5 to VinON
Power input
Ground
CN1-6
CN1-7
CN1-8
Vbr1/Rbr1
Vbr2/Rbr2
Vst
(Output)
Dimmer terminal2
Alarm output
Lump open:5V
GND/0 to 50kΩ
0V/5V
Terminal
number Symbol Rated voltage Remarks
CN2-3 VLOW1(2V) Output 1 return
Output side CN2
CN2-1
CN2-2
VHIGH1
400Vrms
N.C.
Output 1
Terminal
number Symbol Rated voltage Remarks
CN3-3 VLOW2(2V) Output 2 return
Output side CN3
CN3-1
CN3-2
VHIGH2
400Vrms
N.C.
Output 2
unit:mm
・All specifications are subject to change without notice.
2
K-Lamlzia . l‘n CN1-1 9 0V1"; 0v CM” 7237 9 RL 'W 7 cm W" cum CN2-3 v t a rm \0— . 25V~Vm sw1 CN‘ 5 7;, 71? ea RL \oul w" W" fl N1- 0~26v \g’sW C 5 cm 6 cum Rbr 0%qu ems (DIWmin) Vst
Connections
CXA-0326
RLLoad resistance(7W minimum
SW1 Unit operation
aOperation
b Does not operate
OPEN Does not operate
Operate as follows by switching SW1.
Load condition Alarm output
(CN1-8
Normal condition 0.5V max.
When 1 load
(lamp) is run-out 50.5V
When 2 loads
(lamps) are run-out
50.5V
Protection circuit operation
When more than one of RL1-RL2 was
opened, output alarm signal of 5V.
SW2 Unit operation
aVoltage dimmer
Vbr=0 to 2.5V
bVolume dimmer
VR=0 to 50kΩ
Operate as follows by switching SW2.
Vbr=0V:Maximum brightness
Rbr=0Ω:Maximum brightness
・All specifications are subject to change without notice.