Current/Voltage Transducer Monitors

Results: 16
Input Range
0 ~ 100mA0 ~ 1A0 ~ 1mA0 ~ 200mA0 ~ 2A0 ~ 2mA0 ~ 300mA0 ~ 3A0 ~ 3mA0 ~ 4A0 ~ 500mA0 ~ 50A0 ~ 5A
Response Time
8ns-
Operating Temperature
-35°C ~ 70°C-25°C ~ 70°C
Approval Agency
-CE
Stocking Options
Environmental Options
Media
Marketplace Product
16Results
Applied FiltersRemove All

Showing
of 16
Compare
Mfr Part #
Quantity Available
Price
Series
Package
Product Status
Type
Input Range
Output
Isolation
Response Time
Accuracy
Voltage - Supply
Mounting Type
Termination Style
Operating Temperature
Approval Agency
ENCORE
ENCORE (1A)
TRANSDUCER CURRENT SENS SHUNT 1A
Verivolt LLC
1
In Stock
1 : ¥2,405.09000
Box
Box
ActiveCurrent Transducer0 ~ 1A±100mV-8ns±0.2%-Free Hanging (In-Line)BNC-35°C ~ 70°C-
ENCORE
ENCORE (0.1A)
TRANSDUCER CURR SENSE SHUNT 0.1A
Verivolt LLC
1
In Stock
1 : ¥2,405.09000
Box
Box
ActiveCurrent Transducer0 ~ 100mA±100mV-8ns±0.2%-Free Hanging (In-Line)BNC-35°C ~ 70°C-
ENCORE
ENCORE (3A)
TRANSDUCER CURRENT SENS SHUNT 3A
Verivolt LLC
0
In Stock
Check Lead Time
1 : ¥1,659.06000
Box
Box
ActiveCurrent Transducer0 ~ 3A±100mV--±0.2%-Free Hanging (In-Line)BNC-25°C ~ 70°C-
ENCORE
ENCORE (2A)
TRANSDUCER CURRENT SENS SHUNT 2A
Verivolt LLC
0
In Stock
Check Lead Time
1 : ¥1,675.64000
Box
Box
ActiveCurrent Transducer0 ~ 2A±100mV-8ns±0.2%-Free Hanging (In-Line)BNC-35°C ~ 70°C-
ENCORE
ENCORE (4A)
TRANSDUCER CURRENT SENS SHUNT 4A
Verivolt LLC
0
In Stock
Check Lead Time
1 : ¥2,405.09000
Box
Box
ActiveCurrent Transducer0 ~ 4A±100mV--±0.2%-Free Hanging (In-Line)BNC-25°C ~ 70°C-
ENCORE
ENCORE (5A)
TRANSDUCER CURRENT SENS SHUNT 5A
Verivolt LLC
0
In Stock
Check Lead Time
1 : ¥2,405.09000
Box
Box
ActiveCurrent Transducer0 ~ 5A±100mV-8ns±0.2%-Free Hanging (In-Line)BNC-35°C ~ 70°C-
VERY HIGH PERFORMANCE SHUNT
ENCORE (500MA 100MV)
VERY HIGH PERFORMANCE SHUNT
Verivolt LLC
0
In Stock
Check Lead Time
1 : ¥2,405.09000
Box
Box
ActiveCurrent Transducer0 ~ 500mA±100mV--±0.2%-Free Hanging (In-Line)BNC-35°C ~ 70°CCE
VERY HIGH PERFORMANCE SHUNT
ENCORE (4A 100MV)
VERY HIGH PERFORMANCE SHUNT
Verivolt LLC
0
In Stock
Check Lead Time
1 : ¥2,405.09000
Box
Box
ActiveCurrent Transducer0 ~ 4A±100mV--±0.2%-Free Hanging (In-Line)BNC-35°C ~ 70°CCE
VERY HIGH PERFORMANCE SHUNT
ENCORE (1MA 100MV)
VERY HIGH PERFORMANCE SHUNT
Verivolt LLC
0
In Stock
Check Lead Time
1 : ¥2,405.09000
Box
Box
ActiveCurrent Transducer0 ~ 1mA±100mV--±0.2%-Free Hanging (In-Line)BNC-35°C ~ 70°CCE
VERY HIGH PERFORMANCE SHUNT
ENCORE (300MA 100MV)
VERY HIGH PERFORMANCE SHUNT
Verivolt LLC
0
In Stock
Check Lead Time
1 : ¥2,405.09000
Box
Box
ActiveCurrent Transducer0 ~ 300mA±100mV--±0.2%-Free Hanging (In-Line)BNC-35°C ~ 70°CCE
VERY HIGH PERFORMANCE SHUNT
ENCORE (2A 100MV)
VERY HIGH PERFORMANCE SHUNT
Verivolt LLC
0
In Stock
Check Lead Time
1 : ¥2,405.09000
Box
Box
ActiveCurrent Transducer0 ~ 2A±100mV--±0.2%-Free Hanging (In-Line)BNC-35°C ~ 70°CCE
VERY HIGH PERFORMANCE SHUNT
ENCORE (2MA 100MV)
VERY HIGH PERFORMANCE SHUNT
Verivolt LLC
0
In Stock
Check Lead Time
1 : ¥2,405.09000
Box
Box
ActiveCurrent Transducer0 ~ 2mA±100mV--±0.2%-Free Hanging (In-Line)BNC-35°C ~ 70°CCE
VERY HIGH PERFORMANCE SHUNT
ENCORE (3A 100MV)
VERY HIGH PERFORMANCE SHUNT
Verivolt LLC
0
In Stock
Check Lead Time
1 : ¥2,405.09000
Box
Box
ActiveCurrent Transducer0 ~ 3A±100mV--±0.2%-Free Hanging (In-Line)BNC-35°C ~ 70°CCE
VERY HIGH PERFORMANCE SHUNT
ENCORE (200MA 100MV)
VERY HIGH PERFORMANCE SHUNT
Verivolt LLC
0
In Stock
Check Lead Time
1 : ¥2,405.09000
Box
Box
ActiveCurrent Transducer0 ~ 200mA±100mV--±0.2%-Free Hanging (In-Line)BNC-35°C ~ 70°CCE
VERY HIGH PERFORMANCE SHUNT
ENCORE (3MA 100MV)
VERY HIGH PERFORMANCE SHUNT
Verivolt LLC
0
In Stock
Check Lead Time
1 : ¥2,405.09000
Box
Box
ActiveCurrent Transducer0 ~ 3mA±100mV--±0.2%-Free Hanging (In-Line)BNC-35°C ~ 70°CCE
VERY HIGH PERFORMANCE SHUNT
ENCORE (5A 100MV)
VERY HIGH PERFORMANCE SHUNT
Verivolt LLC
0
In Stock
Check Lead Time
1 : ¥2,405.09000
Box
Box
ActiveCurrent Transducer0 ~ 50A±100mV--±0.2%-Free Hanging (In-Line)BNC-35°C ~ 70°CCE
Showing
of 16

Current/Voltage Transducer Monitors


Industrial current or voltage transducers are used to monitor variable or non-sinusoidal sources, trigger peripheral devices in phase-fired control systems, monitor ground current, and other voltage or current monitoring applications. Output types include analog voltage or current, and positive and negative fixed voltages with accuracy from 0.2 to 2%.